Mobile QR Code QR CODE
Export citation EndNote

References

1 
ACI 318 Committee (2019) Building Code Requirements for Structural Concrete (ACI 318-19) and Commentary (ACI 318 R-19). Farmington Hills, MI; American Concrete Institute (ACI).URL
2 
ACI 440 Committee (2015) Guide for the Design and Construction of Structural Concrete Reinforced with Fiber-Reinforced Polymer (FRP) Bars (ACI 440.1R-15). Farmington Hills, MI; American Concrete Institute (ACI).URL
3 
Ahmad, S. H., Zia, P., Yu, T. J., and Xie, Y. (1994) Punching Shear Tests of Slabs Reinforced with 3-Dimensional Carbon Fiber Fabric. Concrete International 16(6), 36-41.URL
4 
Ajami, A. L. (2018) Punching Shear of Concrete Flat Slabs Reinforced with Fiber Reinforced Polymer Bars. University of Bradford. Ph.D. Thesis.URL
5 
Aljazaeri, Z., Alghazali, H. H., and Myers, J. J. (2020) Effectiveness of Using Carbon Fiber Grid Systems in Reinforced Two- Way Concrete Slab System. ACI Structural Journal 117(2).URL
6 
Bank, L. C., Xi, Z., and Munley, E. (1992) Tests of Full-Size Pultruded FRP Grating Reinforced Concrete Bridge Decks. In Materials: Performance and Prevention of Deficiencies and Failures. August 1992. New York: ASCE. 618-631.URL
7 
Banthia, N., Al-Asaly, M., and Ma, S. (1995) Behavior of Concrete Slabs Reinforced with Fiber-Reinforced Plastic Grid. Journal of Materials in Civil Engineering 7(4), 252-257.DOI
8 
BSI (1972) CP 110-1: Code of Practice for the Structural Use of Concrete - Part 1: Design, Materials and Workmanship. November 1972; Incorporating Amendments Issued August 1974 (AMD 1553), February 1976 (Amd 1881) and May 1977 (AMD 2289); Gr 11. London, UK; British Standards Institute (BSI).URL
9 
BSI (1997) BS 8110-1: Structural Use of Concrete - Part 1: Code of Practice for Design and Construction. London, UK; British Standards Institute (BSI).URL
10 
CEB (2010) CEP-FIP Model Code 2010: Bulletin Information No. 203-305. Lausanne, Switzerland; International Federation for Structural Concrete (fib), Comite Euro-International du Beton (CEB).URL
11 
CEN (1991) Eurocode 2: Design of Concrete Structures - Part 1-1: General Rules and Rules for Buildings (BS EN 1992-1- 1:1991). London, UK; European Committee for Standardization (CEN), British Standards Institute (BSI). 211.URL
12 
CSA-A23.3-04 (2004) Design of Concrete Structures for Buildings. Canadian Standards Association (CSA).URL
13 
Dulude, C., Hassan, M., Ahmed, E. A., and Benmokrane, B. (2013) Punching Shear Behavior of Flat Slabs Reinforced with Glass Fiber-Reinforced Polymer Bars. ACI Structural Journal 110(5), 723-34.URL
14 
El-Gamal, S., El-Salakawy, E. F., and Benmokrane, B. (2005) A New Punching Shear Equation for Two-Way Concrete Slabs Reinforced with FRP Bars. ACI Special Publication 230, 877-894.URL
15 
El-Ghandour, A. W., Pilakoutas, K., and Waldron, P. (2003) Punching Shear Behavior of Fiber Reinforced Polymers Reinforced Concrete Flat Slabs: Experimental Study. Journal of Composites for Construction 7(3), 258-265.DOI
16 
fib (2007) FRP Reinforcement in RC Structures (fib Bulletins 40). Lausanne, Switzerland; International Federation for Structural Concrete (fib).URL
17 
Gardner, N. J. (1990) Relationship of the Punching Shear Capacity of Reinforced Concrete Slabs with Concrete Strength. ACI Structural Journal 87(1), 66-71.URL
18 
Gouda, A., and El-Salakawy, E. (2016a) Behavior of GFRP- RC Interior Slab-Column Connections with Shear Studs and High-Moment Transfer. Journal of Composites for Construction 20(4), 04016005.DOI
19 
Gouda, A., and El-Salakawy, E. (2016b) Punching Shear Strength of GFRP-RC Interior Slab-Column Connections Subjected to Moment Transfer. Journal of Composites for Construction 20(1), 04015037.DOI
20 
Hassan, M., Ahmed, E., and Benmokrane, B. (2013) Punching- Shear Strength of Normal and High-Strength Two-Way Concrete Slabs Reinforced with GFRP Bars. Journal of Composites for Construction 17(6), 04013003.DOI
21 
Hassan, M., Fam, A., Benmokrane, B., and Ferrier, E (2017) Effect of Column Size and Reinforcement Ratio on Shear Strength of Glass Fiber-Reinforced Polymer Reinforced Concrete Two-Way Slabs. ACI Structural Journal 114(4), 937- 950.URL
22 
Huang, Z., Zhao, Y., Zhang, J., and Wu, Y. (2020) Punching Shear Behaviour of Concrete Slabs Reinforced with CFRP Grids. Structures 26, 617-625.DOI
23 
Hussein A, Rashid M, and Benmokrane, B. (2004) Two-Way Concrete Slabs Reinforced with GFRP Bars. In Proceeding of 4th International Conference on Advanced Composite Materials in Bridges and Structures. Calgary, Alberta, Canada.URL
24 
Isis Canada. (2001) Reinforcing Concrete Structures with Fibre Reinforced Polymers: Design Manual No. 3. The Canadian Network of Centres of Excellence on Intelligent Sensing for Innovative Structures (ISIS Canada).URL
25 
Jacobson, D. A., Bank, L. C., Oliva, M. G., and Russell, J. S. (2005) Punching Shear Capacity of Double Layer FRP Grid Reinforced Slabs. In Proceeding of 7th International Conference on Fiber Reinforced Plastics for Reinforced Concrete Structures. October 2005, 857-871.URL
26 
Jo, B. W., and Tae, G. H. (2000) Flexural Behavior of Reinforced Concrete Beams Strengthened with Grid-Type Carbon Fiber Plastics. Journal of Ocean Engineering and Technology 14 (1), 52-59. (In Korean)URL
27 
JSCE (1997) Recommendation for Design and Construction of Concrete Structures Using Continuous Fibre Reinforcing Materials. Concrete Engineering, Series 23, A. Machida, ed. Tokyo, Japan; Japan Society of Civil Engineers (JSCE).URL
28 
Ju, M., Ju, J. W. W., and Sim, J. (2021) A New Formula of Punching Shear Strength for Fiber Reinforced Polymer (FRP) or Steel Reinforced Two-Way Concrete Slabs. Composite Structures 259, 113471.DOI
29 
KATS (2017) Fibre-Reinforced Polymer (Frp) Reinforcement of Concrete-Test Methods-Part 1: FRP Bars and GRIDS (KS F ISO 10406-1). Seoul, Korea: Korea Agency for Technology and Standards (KATS), Korea Standard Association (KSA). (In Korean)URL
30 
KCI 112 Committee (2019) FRP Rebar Structural Design Guidelines (KCI PM 112.1-19). Concrete Practical Guideline, Seoul, Korea; Korea Concrete Institute (KCI). (In Korean)URL
31 
Kim, J. S., Jeong, S. M., Kim, H. J., Kim, Y. J., and Park, S. G. (2022) Bond Strength Properties of CFRP Bars according to W/C Ratios and Diameters of the CFRP. Journal of the Korea Concrete Institute 34(6), 675-680. (In Korean)DOI
32 
Lee, H. J., Mun, J. H., Yang, K. H., and Kim, S. J. (2019) Flexural Behavior of Beams Reinforced with Longitudinal GFRP Bars in Exterior Beam-column Connection. Journal of the Korea Concrete Institute 31(3), 211-219. (In Korean)DOI
33 
Lee, H. J., Yang, K. H., Kim, S. J., and Park S. H. (2018) Evaluation on the Bond Stress-Slip Relationship of GFRP Reinforcing Bars with Spiral Ribs. Journal of the Korea Concrete Institute 30(1), 31-38. (In Korean)URL
34 
Lee, J. H., Yoon, Y. S., Cook, W. D., and Mitchell, D. (2009) Improving Punching Shear Behavior of Glass Fiber-Reinforced Polymer Reinforced Slabs. ACI Structural Journal 106(4), 427-434.URL
35 
Matthys, S., and Taerwe, L. (2000a) Concrete Slabs Reinforced with FRP Grids. I: One-Way Bending. Journal of Composites for Construction 4(3), 145-153.DOI
36 
Matthys, S., and Taerwe, L. (2000b) Concrete Slabs Reinforced with FRP Grids. II: Punching Resistance. Journal of Composites for Construction 4(3), 154-161.DOI
37 
MOLIT (2021a) Design of Concrete Structures (KDS 14 20 00: 2021). Sejong, Korea: Ministry of Land, Infrastructure and Transport (MOLIT). (In Korean)URL
38 
MOLIT (2021b) Serviceability Requirements for Concrete Structures (KDS 14 20 30: 2021). Sejong, Korea: Ministry of Land, Infrastructure and Transport (MOLIT). (In Korean)URL
39 
Nawy, E. G., and Neuwerth, G. E. (1977) Fiberglass Reinforced Concrete Slabs and Beams. Journal of the Structural Division 103(2), 421-440.DOI
40 
Nguyen-Minh, L., and Rovňák, M. (2013) Punching Shear Resistance of Interior GFRP Reinforced Slab-Column Connections. Journal of Composites for Construction 17(1), 2-13.DOI
41 
Park, S. Y., and Choi, H. (2004) Failure Mode and Design Guideline for Reinforced Concrete Slab Strengthened Using Carbon FRP Grid. Journal of the Korea Concrete Institute 16(5), 667-675. (In Korean)URL
42 
Rahman, A. H., Kingsley, C. Y., and Kobayashi, K. (2000) Service and Ultimate Load Behavior of Bridge Deck Reinforced with Carbon FRP Grid. Journal of Composites for Construction 4(1), 16-23.DOI
43 
Ramzy, Z., Mahmoud, Z., and Salma, T. (2007) Punching Behavior and Strength of Two-Way Concrete Slab Reinforced with Glass-Fiber Reinforced Polymer (GFRP) Rebars. In Proceeding of Structural Composites for Infrastructures Applications Conference. Hurghada, Egypt.URL
44 
Schmeckpeper, E. R. (1992) Performance of Concrete Beams and Slabs Reinforced with FRP Grids. Doctoral Thesis, University of New Hampshire.URL
45 
Shim, N. H., Kim, J, J., and Park, Y. S. (2002) An Experimental Study on the Strengthening Effect of RC Beam with Carbon Fiber Grid. Journal of the Korea Institute for Structural Maintenance and Inspection 6(4), 107-118. (In Korean)URL
46 
Yost, J. R., and Schmeckpeper, E. R. (2001) Strength and Serviceability of FRP Grid Reinforced Bridge Decks. Journal of Bridge Engineering 6(6), 605-612.DOI
47 
Zaghloul, A., and Razaqpur, A. G. (2004) Punching Shear Strength of Concrete Flat Plates Reinforced with CFRP Grids. In Proceeding of 4th Conference on Advanced Composite Materials in Bridges and Structures. July 2004. ACMBS-IV, Calgary, Alberta.URL
48 
Zhang, B., Masmoudi, R., and Benmokrane, B. (2004) Behaviour of One-Way Concrete Slabs Reinforced with CFRP Grid Reinforcements. Construction and Building Materials 18(8), 625-635.DOI
49 
Zhang, Q., Marzouk, H., and Hussein, A. (2005) A Preliminary Study of High-Sstrength Concrete Two-Way Slabs Reinforced with GFRP Bars. In Proceeding of 33rd CSCE Annual Conference: General Conference and International History Symposium. Canadian Society of Civil Engineers; Toronto, ON, Canada.URL