Title |
Durability Analysis of Underground Structure based on Limit State Function Considering Carbonation
|
Keywords |
내구성 ; 신뢰성지수 ; 환경지수 ; 터널 ; 지하구조물 Durability ; Reliability Index ; Environment factor ; Tunnel ; Underground structure |
Abstract |
The priority of repair areas are chosen with the probability distribution of 0.3mm wide crack and carbonation induced corrosion. Data is analyzed and evaluated based on the 28 section of Precise Inspection for Safety and Diagnosis (PISD) in seoul. As the crack is distributed in log-normal, the carbonation and cover are in normal distribution. To have rational in repair sections among 503 sheets of underground structure, it is adopted the reliability index as well as the environment factors: strength, sonic speed, CO2 concentration, corrosion, and content of chloride.
|