Title Influence of Earthquake Shape on the Dynamic Behavior of Fluid in a Rectangular Structure
Authors 박건(Gun Park) ; 홍기남(Ki-Nam Hong)
DOI https://doi.org/10.11112/jksmi.2017.21.6.059
Page pp.59-66
ISSN 2234-6937
Keywords 유체-구조물 상호작용 ; 지진파 형상 ; 유체 출렁임 형상 ; 출렁임 높이 ; SPH기법 ; 내진설계 Fluid-structure interaction analysis ; Earthquake shape ; Fluid free surface shape ; Sloshing height ; SPH method ; Seismic design
Abstract In the case of fluid storage structure, hydrostatic pressure acts on the structure due to fluid surge during an earthquake. At this time, hydrodynamic pressure of the fluid charge not only by the strength of the earthquake but also by the sloshing height of the fluid. Factors affecting the change of load include the size, width and height of the fluid storage structure and height of fluid, time-history shape, etc. This paper wanted to identify the relationship between the earthquake shape and fluid free surface shape. The sloshing height measured the height of the fluid by applying earthquake to a tank whose width 500mm and comparison of the experiment and analysis. In addition, the shape of the fluid free surface was measured while varying the shape of earthquake and effective of the shape of earthquake of the fluid was analyzed.