Title |
Analytical Study on the Seismic Retrofit Method of Irregular Piloti Building Using Knee-Brace
|
Authors |
유석형(Suk-Hyung Yoo) ; 김달기(Dal-Gee Kim) |
DOI |
https://doi.org/10.11112/jksmi.2020.24.1.35 |
Keywords |
필로티 내진보강; Knee Brace; 내진성능평가; 푸쉬오버 해석 Piloti seismic retrofit; Knee brace; Seismic performance evaluation; Pushover analysis |
Abstract |
Torsional behavior due to the plane irregularities of the piloti building can cause excessive story drift in the torsionally outermost column, which can lead to shear failure of the column. As a seismic retrofit method that can control the torsional behavior of the piloti building, the expansion of RC wall, steel frame or steel brace may be used, but such methods may hinder the openness of the piloti floor. Therefore, in this study, linear dynamic analysis and nonlinear static analysis for piloti buildings retrofitted by knee brace were performed, and seismic performance evaluation and torsion control effect of knee brace were analyzed. The results showed that the shear force of the column increased when the piloti building retrofitted by knee brace, but it was effective in controlling the torsional deformation. In case of retrofit between knee brace and column by 30 °, the shear force of the column increased less than that of 60 °, and the lateral displacement of column was decreased in the order of □, ? and H in cross-section.
|