Title |
Evaluation of Punching Shear Critical Sections in Composite Flat Plates with Different Sizes of Steel Fiber-Reinforced Precast Concrete Regions
|
|
Authors |
김정훈(Jeong-Hoon Kim) ; 이문석(Moon-Seok Lee) ; 최창식(Chang-Sik Choi) ; 배백일(Baek-Il Bae) |
|
DOI |
https://doi.org/10.11112/jksmi.2026.30.5.12 |
|
Keywords |
무량판 슬래브; 프리캐스트 콘크리트 보강재; 뚫림전단; 기둥-슬래브 접합부; 강섬유 Flat plate slab; Precast concrete reinforcement; Punching shear; Slab-column connection; Steel fiber |
|
Abstract |
This study investigated the punching shear behavior and failure regions of composite flat plates locally strengthened with high-strength steel fiber-reinforced precast concrete. The main variables were the PC region width and the presence of steel fibers. The peak loads of the strengthened specimens were 33.1?127.6% higher than that of the RC reference specimen. Specimens PC-0%-2h, PC-1%-2h, and PC-0%-4h failed within the PC region, whereas external failure in the cast-in-place concrete was observed only in PC-1%-4h. The experimental strengths were compared with predictions based on KDS 14 20 22, ACI 318, Eurocode 2, and a CSCT-based model using sections measured from the column face and the outer edge of the PC region. The results showed that the relevant calculation section and material properties depended on the observed failure region. Because external failure occurred in only one specimen, the findings were limited to the tested conditions.
|