Mobile QR Code QR CODE

Journal of the Korea Concrete Institute

J Korea Inst. Struct. Maint. Insp.
  • Indexed by
  • Korea Citation Index (KCI)

References

1 
ACI Committee 318 (2025), Building Code Requirements for Structural Concrete (ACI 318-25) and Commentary, Farmington Hills, MI: American Concrete InstituteGoogle Search
2 
Choi, K. K., Reda Taha, M. M., Park, H. G., Maji, A. K. (2007), Punching Shear Strength of Interior Concrete Slab-Column Connections Reinforced with Steel Fibers, Cement and Concrete Composites, 29(5), 409-420., ElsevierDOI
3 
European Committee for Standardization (2004), Eurocode 2: Design of Concrete Structures—Part 1-1: General Rules and Rules for Buildings, EN 1992-1-1:2004+A1:2004, BrusselsGoogle Search
4 
fib (2013), fib Model Code for Concrete Structures 2010, 144-150., Berlin, Germany: Wilhelm Ernst & SohnGoogle Search
5 
Gołdyn, M., Urban, T. (2022), UHPFRC Hidden Capitals as an Alternative Method for Increasing Punching Shear Resistance of LWAC Flat Slabs, Engineering Structures, 271, ElsevierDOI
6 
Joh, C. B., Kim, B. S., Hwang, H. H., Choi, K. K., Choi, S. H. (2011), Punching Shear Strength of Deck Slabs Made of Ultra High Performance Concrete, Journal of the Korea Institute for Structural Maintenance and Inspection, 15(4), 221-231. (in Korean)DOI
7 
Kim, H. K. (2006), Structural Performance of Column-Slab Connection in Flat Plate System Using High Strength Concrete, Journal of the Korea Institute for Structural Maintenance and Inspection, 10(1), 97-105. (in Korean)Google Search
8 
Korea Construction Standards Center (2022), KDS 14 20 22: Concrete Structural Design Code - Shear and Torsion, Korea: Korea Construction Standards Center (in Korean)Google Search
9 
Korean Agency for Technology and Standards (KATS) (2003), Method of Tensile Test for Metallic Materials, KS B 0802, Seoul, Korea: Korean Standards Association (in Korean)Google Search
10 
Korean Agency for Technology and Standards (KATS) (2014), Standard Test Method for Flexural Performance of Fiber Reinforced Concrete, KS F 2566, Seoul, Korea: Korean Standards Association (in Korean)Google Search
11 
Korean Agency for Technology and Standards (KATS) (2016), Standard Test Method for Flexural Strength of Concrete, KS F 2408, Seoul, Korea: Korean Standards Association (in Korean)Google Search
12 
Korean Agency for Technology and Standards (KATS) (2022), Test Method for Compressive Strength of Concrete, KS F 2405, Seoul, Korea: Korean Standards Association (in Korean)Google Search
13 
Maya, L. F., Fernández Ruiz, M., Muttoni, A., Foster, S. J. (2012), Punching Shear Strength of Steel Fibre Reinforced Concrete Slabs, Engineering Structures, 40, 83-94., ElsevierDOI
14 
Muttoni, A. (2008), Punching Shear Strength of Reinforced Concrete Slabs without Transverse Reinforcement, ACI Structural Journal, 105(4), 440-450., American Concrete InstituteDOI
15 
Zhou, Y., Shou, H., Li, C., Jiang, Y., Tian, X. (2025), Punching Shear Behavior of Ultra-High-Performance Fiber-Reinforced Concrete and Normal Strength Concrete Composite Flat Slabs, Engineering Structures, 322, ElsevierDOI
16 
Zohrevand, P., Yang, X., Jiao, X., Mirmiran, A. (2015), Punching Shear Enhancement of Flat Slabs with Partial Use of Ultrahigh-Performance Concrete, Journal of Materials in Civil Engineering, 27(9), American Society of Civil EngineersDOI