Mobile QR Code QR CODE

Journal of the Korea Concrete Institute

J Korea Inst. Struct. Maint. Insp.
  • Indexed by
  • Korea Citation Index (KCI)
1 
Nami, A. (2010), FRP Reinforcement for Bridge Structures, Proceedings, Structural Engineering Conference Beams, Journal of Composites for Construction, FRP Reinforcement for Bridge Structures, Proceedings, Structural Engineering Conference Beams, Journal of Composites for Construction, 5(1), 12-17.1090-0268, 5(1), 12-17.Google Search
2 
ACI Committee 440 (2002), Guide for the Design and Construction of Concrete Reinforced with FRP Bars. (ACI440.2R-02), American Concrete Institute, 41.Google Search
3 
Lim, D. H. (2008), An Experimental Study on the Flexural Behavior of RC Beams Strengthened with Near-Surface-Mounted CFRP Strips, Journal of the Korea Institute for Structural Maintenance andInspection, 12(6), 89-96.Google Search
4 
Oehlers, D. J., Rashid, R., Seracino, R. (2007), IC debonding resistance of group of FRP NSM strips in reinforced concrete beams, IC debonding resistance of group of FRP NSM strips in reinforced concrete beams, ELSEVIER.Google Search
5 
Maruyma, I., Sogo, M., Sogabe, T., Sato, R., Kawai, K. (2004), Flexural Properties of Reinforced Recycled Concrete Beams, Proceedings RILENM Symp. International RILEM Conference on the Use of Recycled Materials in Buildings and Structures, Flexural Properties of Reinforced Recycled Concrete Beams, Proceedings RILENM Symp. International RILEM Conference on the Use of Recycled Materials in Buildings and Structures, 525-535., 525-535.Google Search
6 
Yost, J. R., Gross, S. P., Dinehart, D. W., Mildenberg, J. J. (2007), Flexural Behavior of Concrete Beams Strengthened with Near-Surface Mounted CFRP Strips, ACI Structural Journal, Flexural Behavior of Concrete Beams Strengthened with Near-Surface Mounted CFRP Strips, ACI Structural Journal, 104(4), 430-437.0889-3241, 104(4), 430-437.Google Search
7 
De Lorenzis, L., Teng, J. G. (2007), Near-surface mounted FRP reinforcement: An emerging technique for strengthening structures, Composite Part B, Near-surface mounted FRP reinforcement: An emerging technique for strengthening structures,Composite Part B, 38, 119-143. 10.1016/j.compositesb.2006.08.003, 38, 119-143.DOI
8 
De Lorenzis, L., Nanni, A., La Tegola, A. (2000), Flexural and Shear Strengthening of Reinforced Concrete Structures with Near Surface Mounted FRP Rods, Flexural and Shear Strengthening of Reinforced Concrete Structures with Near Surface Mounted FRP Rods, Proceedings ACMBS III Symp. The 3rdInternational Conference on Advanced Composite Materials in Bridges and Structures (ACMBS III), 521-528.Google Search
9 
Ministry of Environment (2010), Construction Waste Recy cling Promotion Act.Google Search
10 
R. EI-Hacha and S. H. Rizkalla (2004), Near-Surface -Mounted Fiber-Reinforced Polymer Reinforcements for Flexural Strengthening of concrete Structures, ACI Structural Journal, Near-Surface -Mounted Fiber-Reinforced Polymer Reinforcements for Flexural Strengthening of concrete Structures, ACI Structural Journal, 101(5), 717-726.0889-3241, 101(5), 717-726.Google Search
11 
Seracino, R., Raizal Saifulnaz, M. R, Oehlers, D. J. (2007), Generic intermediate crack debonding resistance of EB and NSM plateto- concrete joints, Composite Construction Journal, Generic intermediate crack debonding resistance of EB and NSM plateto- concrete joints, Composite Construction Journal, 11(1), 62-70. 10.1061/(ASCE)1090-0268(2007)11:1(62), 11(1), 62-70.DOI
12 
Song, S. H., Choi, K. S, You, Y. C., Kim, K. H., Yun, H. D. (2009), Flexural Behavior of Reinforced Recycled Aggregate Concrete Beams, Journal of the Korea Concrete Institute, Flexural Behavior of Reinforced Recycled Aggregate Concrete Beams, Journal of the Korea Concrete Institute, 21(4), 431-439. 10.4334/JKCI.2009.21.4.431, 21(4), 431-439.DOI
13 
Rizkalla, S. (2004), Near-Surface- Fiber-Reinforced Polymer Reinforcements for Flexural Strengthening of ConcreteStructures, ACI Structural Journal, Near-Surface- Fiber-Reinforced Polymer Reinforcements for Flexural Strengthening of ConcreteStructures, ACI Structural Journal, 101(5), 717-726.0889-3241, 101(5), 717-726.Google Search
14 
Seo, S. Y., Choi, K. B., Kwon, Y. S. (2012), Retrofit Capacity of Near-Surface-Mounted RC Beam by using FRP Plate, Journal of the Korea Institute for Structural Maintenance and Inspection, Retrofit Capacity of Near-Surface-Mounted RC Beam by using FRP Plate, Journal of the Korea Institute for Structural Maintenance and Inspection, 16(1),18-26. 10.11112/jksmi.2012.16.1.018, 16(1), 18-26.DOI
15 
Lee, Y. T., Hong, S. U., Kim, S. H., Baek, S. K., Cho, Y. S. (2014), Flexural Behavior of High Strength Reinforced Concrete Beams by Replacement Ratios of Recycled Coarse Aggregate, Journal of theKorea Institute for Structural Maintenance and Inspection, 18(1), 1-9.Google Search