JKSMI
Journal of the Korea Institute for
Structural Maintenance and Inspection
KSMI
Contact
Open Access
Bi-monthly
ISSN : 2234-6937 (Print)
ISSN : 2287-6979 (Online)
http://journal.auric.kr/jksmi/
Mobile QR Code
Journal of the Korea Concrete Institute
J Korea Inst. Struct. Maint. Insp.
Indexed by
Korea Citation Index (KCI)
Main Menu
Main Menu
About Journal
Aims and Scope
Subscription Inquiry
Editorial Board
For Contributors
Instructions For Authors
Ethical Guideline
Crossmark Policy
Submission & Review
Archives
Current Issue
All Issues
Journal Search
Home
All Issues
2020-10
(Vol.24 No.5)
10.11112/jksmi.2020.24.5.17
Journal XML
XML
PDF
INFO
REF
References
1
Park, B. C.Study on Seismic Retrofitting Techniques for Unreinforced Masonry Buildings, National Fire Agency, Korea
2
Churilov, S., Dumova, E. J. (2013), In-plane Shear Behaviour of Unreinforced and Jacketed Brick Masonry Walls, Soil Dynamics and Earthquake Engineering, 50, 85-105.
3
Yang, K. H., Joo, D. B., Sim, J. I., Kang, J. H. (2012), In-plane Seismic Performance of Unreinforced Masonry Walls Strengthened with Unbonded Prestressed Wire Rope Units, Engineering Structures, 45(), 449-459.
4
Hernan, S. M., Pablo, A. (2011), Repair of In-plane Shear Damaged Masonry Walls with External FRP, Construction and Building Materials, 25(3), 1172-1180.
5
Taghdi, M., Bruneau, M., Satcioglu, M. (2000), Seismic Retrofitting of Low-rise Masonry and Concrete Walls Using Steel Strips, Journal of Structural Engineering ASCE, 126(9), 1017-1025.
6
Lee, J. H., Kim, K. M., Kim, H. W., Kim, J. S., Oh, S. H., Lee, S. H. (2014), Seismic Retrofitting Effects of Retrofitted Unreinforced Masonry Walls Using Metal Laths and Steel Plates, Korean Society of Hazard Mitigation, 14(3), 63-70.
7
Lee, J. H. (2004), Seismic Capacity and Seismic Retrofitting of Low Rise Buildings, Ph.D. dissertation, Kwangwoon University, Department of Architecture Engineering
8
Architectural Institute of Korea, (2016), Korean Building Code, (KBC 2016), Architectural Institute of Korea (AIK), Korea, Seoul
9
Federal Emergency Management Agency, (1999), Evaluation of Earthquake Damaged Concrete and Masonry Wall Buildings, (FEMA 306), Applied Technology Council (ATC), USA, Washington, D.C
10
Korean Agency for Technology and Standard(KATS), (2013), Concrete Bricks, (KS F 4004), Korean Standard Association(KSA), Korea, Seoul
11
Korean Agency for Technology and Standard(KATS), (2017), Standard Test Method for Static Modulus of Elasticity and Poisson’s Ratio in Compression of Cylindrical Concrete Specimens, (KS F 2438), Korean Standard Association(KSA), Korea, Seoul
12
American Society for Testing and Materials, (2007), Standard Test Method for Compressive Strength of Masonry Prisms, (ASTM C 1314), (KS F 2438), Korean Standard Association(KSA), Korea, Seoul
13
American Society for Testing and Materials, (2003), Standard Test Method for Diagonal Tension(Shear) in Masonry Assemblages, (ASTM E 519), ASTM International, USA, Philadelphia