Mobile QR Code QR CODE

Journal of the Korea Concrete Institute

J Korea Inst. Struct. Maint. Insp.
  • Indexed by
  • Korea Citation Index (KCI)

References

1 
Abbas, Y., Pargar, F., Koleva, D. A., van Breugel, K., Olthuis, W., van den Berg, A. (2018), “Non-destructive measurement of chloride ions concentration in concrete – A comparative analysis of limitations and prospects”, Construction and Building Materials, vol(174), 376-387.DOI
2 
Angst, U. M., Polder, R. (2014), Spatial variability of chloride in concrete within homogeneously exposed areas, Cement and Concrete Research, 56, 40-51.DOI
3 
ASTM C 1202, (2022), Standard test method for electrical indication of concrete's ability to resist chloride ion penetration, ASTM International, West ConshohockenGoogle Search
4 
BS EN 206, (2014), Concrete-Specification, perforamnce, production and conformity, British Standards, Institution, LondonGoogle Search
5 
Delagrave, A., Bigas, J. P., Ollivier, J. P., Marchand, J., Pigeon, M. (1997), Influence of the interfacial zone on the chloride diffusivity of mortars, Advanced Cement Based Materials, 5(3–4), 86-92.DOI
6 
Kim, K-. S., Park, K-. T., Kim, J. (2020), Evaluating chloride absorption of reinforced concrete structures with crack widths, Journal of the Korea Institute for structural Maintenance and Inspection, 24(6), 10-16.DOI
7 
Kim, K-. S., Park, K-. T., Kim, J. (2021), FEA simulations on water absorption in various pre-cracked concretes, Journal of the Korea Institute for structural Maintenance and Inspection, 25(5), 68-75.DOI
8 
Kim, M-. Y., Yang, E-. I., Yi, S-. T. (2013), Application of the colorimetric method to chloride diffuison evaluation in concrete structures, Construction and Building Materials, 41, 239-245.DOI
9 
KS F 2405, (2010), Standard test method for compressive strength of concrete, Korean Standards AssociationGoogle Search
10 
NT Build 492, (1999), Concrete, mortar and cement-based repair materials:Chloirde migration coefficient from non-steady-state migration experiments, Nordtest, EspooGoogle Search
11 
Sajid, H. U., Jalal, A., Kiran, R., Al-Rahim, A. (2022), A survey on the effects of deicing materials on properties of Cement-based materials, Construction and Building Materials, 319, 126062DOI
12 
Streicher, P. E., Alexander, M. G. (1995), A chloride conduction test for concrete, Cement and Concrete Research, 25(6), 1284-1294.DOI
13 
Tuutti, K. (1982), Corrosion of steel in concrete, Swedish Cement and Concrete Research Institute, StockholmGoogle Search
14 
Ye, H., Tian, Y., Jin, N., Jin, X., Fu, C. (2013), Influence of cracking on chloride diffusivity and moisture influential depth in concrete subjected to simulated environmental conditions, Construction and Building Materials, 47, 66-79.DOI