Mobile QR Code QR CODE

Journal of the Korea Concrete Institute

J Korea Inst. Struct. Maint. Insp.
  • Indexed by
  • Korea Citation Index (KCI)

References

1 
Angst, U. M., Hooton, R. D., Marchand, J., Page, C. L., Flatt, R. J., Elsener, B., Gehlen, C., Culikers, J. (2012), Present and Future Durability Challengers for Reinforced Concrete Structures, Materials and Corrosion, 63(12), 1047-1051.DOI
2 
Han, M. S., Park, J. H., Lee, J. H., Min, J. Y. (2021), Analysis of structural safety for rebar exposure and corrosion in PSC I-girder bridge slab, Journal of the Korea Institute of Structural Maintenance and Inspection, 25(1), 67-74.DOI
3 
Oh, K. S., Park, K. T., Kwon, S. J. (2016), Evaluation of Anti-Corrosion Performance of FRP Hybrid Bar with Notch in GGBFS Concrete, Journal of the Korea Institute of Structural Maintenance and Inspection, 20(4), 51-58.DOI
4 
Stefanoni, M., Angst, U., Elsener, B. (2018), Corrosion rate of carbon steel in carbonated concrete – A critical review, Cement and Concrete Research, 103, 35-48.DOI
5 
Woo, S. K., Lee, Y. (2014), Probabilistic Estimation of Service Life of Box Culvert for Power Transmission Considering Carbonation and Crack Effect, Journal of the Korea Institute of Structural Maintenance and Inspection, 18(6), 30-40.DOI
6 
Abbas, M., Shafiee, M. (2020), An Overview of Maintenance Management Strategies for Corroded Steel Structures in Extreme Marine Environments, Marine Structures, 71, 102718DOI
7 
Nanni, A., De Luca, A., Zadeh, H. J. (2014), Reinforced Concrete with FRP Bars: Mechanics and Design, CRS Press, FL, USA, 35-63.Google Search
8 
ACI Committee 440, (2015), Guide for the Design and Construction of Structural Concrete Reinforced with Fiber-Reinforced Polymer(FRP) Bars (ACI 440.1R-15), American Concrete Institute, Farmington Hills, MI., USA.Google Search
9 
Barris, C., Torres, L., Vilanova, I., Miàs, C., Llorens, M. (2017), Experimental study on crack width and crack spacing for Glass-FRP reinforced concrete beams, Engineering Structures, 131, 231-242.DOI
10 
Cho, J. R., Park, Y. H., Park, S. Y., Cho, K. H., Kim, S. T. (2015), Governing Design Factors of GFRP-Reinforced Concrete Bridge Deck, Journal of the Korean Society of Safety, 30(6), 70-77.DOI
11 
KCI(Korea Concrete Institute), Design Guideline of FRP-Reinforced Concrete Structure (KCI-M-19-001), Korea Concrete Institute, Korea.Google Search
12 
MOLIT(Ministry of Land, Infrastructure and Transport), (2022), KDS 14 20 20: Design Standard for Flexure and Axial Load, MOLIT, KoreaGoogle Search
13 
MOLIT(Ministry of Land, Infrastructure and Transport), (2021), KDS 14 20 30: Design Standard for Serviceability of Concrete Structure, MOLIT, KoreaGoogle Search
14 
Frosch, R. J. (1999), Another Look at Cracking and Crack Control in Reinforced Concrete, ACI Structural Journal, 96(3), 437-442.URL
15 
ACI Committee 318, (2019), Building Code Requirements for Structural Concrete and Commentary (ACI 318-19), American Concrete Institute, Farmington Hills, MI, USAGoogle Search
16 
Min, C. S. (2012), Crack Control in Beams and One-Way Slabs, Journal of the Korea Concrete Institute, 24(4), 381-390.DOI
17 
CSA(Canadian Standards Association), (2014), Canadian Highway Bridge Design Code (CAN/CSA-S6-14), CSA Group, ON, CanadaGoogle Search
18 
Gergely, P. (1981), Role of Cover and Bar Spacing in Reinforced Concrete, Significant Developments in Engineering Practise and Research: A Tribute to Chester P. Siess, SP-75, American Concrete Institute, Farmington Hills, MI, USA, 133-147.URL
19 
Darwin, D., Hognestad, E., Beeby, A., Rice, P. (1985), Debate: Crack Width, Cover, and Corrosion, Concrete International, 8(5), 20-35.Google Search
20 
Oesterle, R. G. (1997), The Role of Concrete Cover in Crack Control Criteria and Corrosion Protection, PCA R&D Serial No. 2054, Portland Cement Association, IL, USAGoogle Search
21 
AASHTO(American Association of State Highway and Transportation Officials), (2009), AASHTO LRFD Bridge Design Guide Specifications for GFRP-Reinforced Concrete Bridge Decks and Traffic Railings, DC, USAGoogle Search
22 
JSCE(Japan Society of Civil Engineers), (1997), Recommendation for Design and Construction of Concrete Structures Using Continuous Fiber Reinforcing Materials, Concrete Engineering Series No. 23, Japan, 325.Google Search