JKSMI
Journal of the Korea Institute for
Structural Maintenance and Inspection
KSMI
Contact
Open Access
Bi-monthly
ISSN : 2234-6937 (Print)
ISSN : 2287-6979 (Online)
http://journal.auric.kr/jksmi/
Mobile QR Code
Journal of the Korea Concrete Institute
J Korea Inst. Struct. Maint. Insp.
Indexed by
Korea Citation Index (KCI)
Main Menu
Main Menu
About Journal
Aims and Scope
Subscription Inquiry
Editorial Board
For Contributors
Instructions For Authors
Ethical Guideline
Crossmark Policy
Submission & Review
Archives
Current Issue
All Issues
Journal Search
Home
All Issues
2022-10
(Vol.26 No.5)
10.11112/jksmi.2022.26.5.1
Journal XML
XML
PDF
INFO
REF
References
1
Agnihotri, P., Singhal, V., Durgesh, C. R. (2013), Effect of In-plane Damage on Out-of-plane Strength of Unreinforced Masonry Walls, Engineering Structures, 57, 1-11.
2
ASTM C 1314, (2007), Standard Test Method for Compressive Strength of Masonry Prisms, ASTM International, Philadelphia, USA.
3
ASTM E 519, (2003), Standard Test Method for Diagonal Tension(Shear) in Masonry Assemblages, ASTM International, Philadelphia, USA.
4
Bae, B. I., Yun, H. J., Choi, C. S., Choi, H. K. (2012), Evaluation of Shear Strength of Unreinforced Masonry Walls Retrofitted by Fiber Reinforced Polymer Sheet, Journal of the Korea Concrete Institute, 24(3), 305-313.
5
Hwang, S. H., Yang, K. H., Kim, S. (2021a), Evaluation on Seismic Performance of Masonry Walls Strengthened with Unbonded Steel-Bar Truss Systems, Journal of the Korea Concrete Institute, 33(2), 117-124.
6
Hwang, S. H., Yang, K. H., Kim, S. (2021b), In-plane and Out-of-plane Seismic Performances of Masonry Walls Strengthened with Steel-Bar Truss Systems, Journal of the Korea Institute for Structural Maintenance and Inspection, 25(1), 16-24.
7
KS F 2438, (2017), Standard Test Method for Static Modulus of Elasticity and Poisson’s Ratio in Compression of Cylindrical Concrete Specimens, KSA, Seoul, Korea. (In Korean).
8
KS F 4004, (2013), Concrete Bricks, KSA, Seoul, Korea. (In Korean).
9
Lee, J. H. (2005), Seismic Capacity and Seismic Retrofitting of Low Rise Buildings Unreinforced Masonry, Brick-infilled RC Frame and Steel Slit Damper Retrofitted RC Frame. Ph.D. Thesis. Kwangwoon University. (In Korean).
10
MOLIT, (2020), Number of Non-Reinforced Masonry Buildings Nationwide, Sejong, Korea: Ministry of Land, Infrastructure, and Transport. Available at: https://blcm.go.kr/stat/customizedStatic/Customized StaticSupplyList.do
11
NIDP, (2009), Study on Seismic Retrofitting Techniques for Unreinforced Masonry Buildings, National Emergency Management Agency, Seoul, Korea. (In Korean).