References

1 
Andrade, C., and Alonso, C. (2004), Test methods for on-site corrosion rate measurement of steel reinforcement in concrete by means of the polarization resistance method, Materials and Structures, 37, 623-643.DOI
2 
Jang, B. S, Cha, H. Y., Ahn, J. H., and Kim, B.S. (2009), Case study of corrosion monitoring sensor for marine RC structure, Spring Conference of Korea Concrete Institute, 263-264.URL
3 
Kim, H. S., Lee, C. H., Moon, C. H., and Ahn, T. S. (2008), Application of long-term monitoring sensor for detection of steel corrosion in RC structure under marine environment, Conference of Korean Society of Civil Engineers, 10, 2645-2648.URL
4 
Kim, J. K., Kee, S.-H., Futalan, C. M. and Yee, J. J. (2020), Corrosion monitoring of reinforced steel embedded in cement mortar under wet-and-dry cycles by electrochemical impedance spectroscopy, Sensors, 20(1), 199.DOI
5 
Kho, Y. T., (1999) The fundamentals of Corrosion and Anti- corrosion, The Corrosion Science Society of Korea, 3-14.URL
6 
Macdonald, D. D. (2006), Reflections on the history of electrochemical impedance spectroscopy, Electrochimica Acta, 51, 1376-1388.DOI
7 
Martin, M., Gebara, F. H., Strong, T. D., and Brown, R. B. (2009), A fully differential potentiostat, IEEE Sensors Journal, 9(2), 135-142.DOI
8 
Mehta, P. K. and Monteriro, P. J. M., (2003), Concrete: Microstructure, Properties, and Materials 4th Edition, McGraw Hill, 113-187.URL
9 
Montemor, M. F., Simoes, A. M. P., and Ferreira, M. G. S. (2003), Chloride- induced corrosion on reinforcing steel: From the fundamentals to the monitoring techniques, Cement and Concrete Composites, 25, 491-502.DOI
10 
Neville, A. M. (2011), Properties of Concrete 5th edition, Prentice Hall, 483-538.DOI
11 
Nishikata, A., Zhu, Q., and Tada, E. (2014), Long-term monitoring of atmospheric corrosion at weathering steel bridges by an electrochemical impedance method, Corrosion Science, 87, 80-88.URL
12 
Pacheco-Torgal, F. (2018), Introduction. In Eco-Efficient Repair and Rehabilitation of Concrete Infrastructures, Elsevier, Amsterdam, The Netherlands, 1-12.URL
13 
Rodrigues, R., Gaboreau, S., Gance, J. Ignatiadis, I., and Betelu, S. (2021), Reinforced concrete structures: A review of corrosion mechanisms and advances in electrical methods for corrosion monitoring, Construction and Building Materials, 269, 121240.DOI
14 
Ribeiro, D.V., and Abrantes, J. C. C. (2016), Application of electrochemical impedance spectroscopy (EIS) to monitor the corrosion of reinforced concrete: A new approach, Construction and Building Materials, 111, 98-104.DOI
15 
So, H.-S. (2006), Influence and assessment of corrosion rate of reinforcing bars using the linear polarization resistance technique, Journal of the Architectural Institute of Korea- Structure and Construction, 22(2), 107-114.URL
16 
Stern, M. and Geary, A.I. (1957), Electrochemical Polarization: I. A theoretical Analysis of the Shape of Polarization Curves, Journal of the Electrochemical Society, 104(1), 56-63.DOI
17 
Verma, S. K., Bhadauria, S. S., and Akhtar, S. (2013), Review of Nondestructive Testing Methods for Condition Monitoring of Concrete Structures, Journal of Construction Engineering, 834572.URL
18 
Yadav, A. P., Nishikata, A., and Tsuru, T. (2004), Electrochemical impedance study on galvanized steel corrosion under cyclic wet-dry conditions-influence of time of wetness, Corrosion Science, 46, 169-181.DOI