• 대한전기학회
Mobile QR Code QR CODE : The Transactions of the Korean Institute of Electrical Engineers
  • COPE
  • kcse
  • 한국과학기술단체총연합회
  • 한국학술지인용색인
  • Scopus
  • crossref
  • orcid
Title An Experimental Study on Load Unbalance in Electric Railway Feeding System
Authors 권호준(Ho-Jun Kwon) ; 최용은(Yong-Eun Choi) ; 오효석(Hyo-Seok Oh) ; 김재문(Jae-Moon Kim)
DOI https://doi.org/10.5370/KIEE.2022.71.5.789
Page pp.789-796
ISSN 1975-8359
Keywords Scott transformer; Load Unbalance; Electric Railway Feeding System; Simulator
Abstract The domestic AC railway power supply system uses a scott transformer with two single-phase transformers T-connected for resolving the unbalance on the AC 3-phase power supply side. However, when single-phase M-phase and T-phase railway vehicles on the secondary side of the scott transformer exist as single-phase loads with different capacity, unbalance of current on the power supply side occurs.
In this paper, In this paper, simulations were performed according to theoretical considerations and experiments were performed using a prototype simulator. The current unbalance on the power supply system was investigated when there was an impedance deviation between the windings of the Scott transformer and electric railway vehicles with different capacities were present on the secondary side catenary. The average error rate of the calculated value obtained through the formula and the simulation result value was within 1.68%, confirming that the implementation of railway power supply system modeling was confirmed. Also, it was confirmed that the impedance difference between the Scott transformer windings and the M-phase and T-phase load capacity unbalance cause unbalance in the current flowing in the power system.