• 대한전기학회
Mobile QR Code QR CODE : The Transactions of the Korean Institute of Electrical Engineers
  • COPE
  • kcse
  • 한국과학기술단체총연합회
  • 한국학술지인용색인
  • Scopus
  • crossref
  • orcid

References

1 
Heising, C., IEEE recommended practice for the design of reliable industrial, and commercial power systems, IEEE Inc., pp. 149~150, 2007.URL
2 
Chen, C. S., et al., “Design of undervoltage relay setting for an industrial plant with cogeneration units to enhance power quality of critical loads,” IEEE Transactions on Industry Applications, vol. 44, no. 4, pp. 1295~1302, 2008.DOI:10.1109/TIA.2008.926057DOI
3 
Ilyushin, Pavel V., Aleksandr L. Kulikov, and Sergey P. Filippov. “Adaptive algorithm for automated undervoltage protection of industrial power districts with distributed generation facilities,” 2019 International Russian Automation Conference (RusAutoCon), IEEE, pp. 1~6, 2019.DOI:10.1109/RUSAUTOCON.2019.8867807DOI
4 
T. P. Sari, et al., “Enhancing the coordination of reverse power, overcurrent, under-frequency, and under-voltage relays using transient stability analysis in real plant applications,” Ain Shams Engineering Journal, vol. 11, no. 1, pp. 1~9, 2020. DOI:10.1016/j.asej.2019.06.001DOI
5 
O.-B. Hyun, et al., “Application of a hybrid SFCL in KEPCO grid and local points at issue,” IEEE Transactions on Applied Superconductivity, vol. 19, no. 3, pp. 1946~1949, 2009.DOI:10.1109/TASC.2009.2018256DOI
6 
O.-B. Hyun, et al., “Long-term operation and fault tests of a 22.9 kV hybrid SFCL in the KEPCO test grid,” IEEE Transactions on Applied Superconductivity, vol. 21, no. 3, pp. 2131~2134, June 2011.DOI:10.1109/TASC.2010.2089587DOI
7 
H.-R. Kim, et al., “Development and grid operation of superconducting fault current limiters in KEPCO,” IEEE Transactions on Applied Superconductivity, vol. 24, no. 5, pp. 1~4, 2014.DOI:10.1109/TASC.2014.2346486DOI
8 
Y.-H. Han, et al., “Development and long-term test of a compact 154-kV SFCL,” IEEE Transactions on Applied Superconductivity, vol. 29, no. 4, pp. 1~6, 2018.DOI:10.1109/TASC.2018.2880325DOI
9 
C. Lee, et al., “Progress of the first commercial project of high-temperature superconducting cables by KEPCO in Korea,” Superconductor Science and Technology, vol. 33, no. 4, pp. 1~7, 2020.DOI:10.1088/1361-6668/ab6ec3DOI
10 
J. Zhu, et al., “Design, verification, and protection setting of superconducting fault current limiter for a 10 kV power network,” Journal of Superconductivity and Novel Magnetism, vol. 36, no. 2, pp. 455~465, 2023.DOI
11 
S.-H. Lim, and M.-K. Park, “Analysis on protection coordination of OCRs using voltage components for the application of SFCL in a power distribution system with DG,” IEEE Transactions on Applied Superconductivity, vol. 31, no. 5, pp. 1~6, 2021.DOI:10.1109/TASC.2021.3066045DOI
12 
Y. J. Cho, and S.-H. Lim, “Analysis on protection coordination of OCRs using index for impedance compensation considering unsymmetrical ground fault in a power distribution system with SFCL,” IEEE Transactions on Applied Superconductivity, vol. 33, no. 5, pp. 1~6, 2023.DOI:10.1109/TASC.2023.3262765DOI
13 
M.-K. Park, and S.-H. Lim, “Impedance compensation method of protective relay for SFCL's application in a power distribution system,” IEEE Transactions on Applied Superconductivity, vol. 31, no. 5, pp. 1~6, 2021.DOI:10.1109/TASC.2021.3059989DOI
14 
S.-T. Lim, and S.-H. Lim, “Analysis on protective coordination between over-current relays with voltage component in a power distribution system with SFCL,” IEEE Transactions on Applied Superconductivity, vol. 30, no. 4, pp. 1~6, 2020.DOI:10.1109/TASC.2020.2968252DOI
15 
J. S. Kim, S. H. Lim, and J. C. Kim, “Analysis on fault current limiting and bus-voltage sag suppressing operations of SFCLs using magnetic coupling of two coils according to their application locations in a power distribution system,” Physica C: Superconductivity and Its Applications, vol. 471, no. 21–22, pp. 1358~1363, 2011.DOI:10.1016/j.physc.2011.05.194DOI