• 대한전기학회
Mobile QR Code QR CODE : The Transactions of the Korean Institute of Electrical Engineers
  • COPE
  • kcse
  • 한국과학기술단체총연합회
  • 한국학술지인용색인
  • Scopus
  • crossref
  • orcid

References

1 
S. Ouanes, et al., “Contribution to fault analysis and transformer- protection using symmetrical components,” in 2024 2nd ICEEAC, IEEE, 2024. DOI:10.1109/ICEEAC61226.2024.10576547DOI
2 
M. Jovan, et al., “Power definitions for three-phase systems in terms of instantaneous symmetrical components,” International Journal of Electrical Power & Energy Systems 147, vol. 147, 2023. DOI:10.1016/j.ijepes.2022.108808DOI
3 
D. V. Tien and R. Gono, “Developing a tool for symmetrical and unsymmetrical faults analysis in power system,” 2021 ICSSE, IEEE, 2021. DOI:10.1109/ICSSE52999.2021.9538422DOI
4 
M. R. Barzegar‐Bafrooei et al., “On the advance of SFCL: A comprehensive review,” IET Generation, Transmission & Distribution, vol. 13, iss. 17, pp. 3745-3759, 2019. DOI:10.1049/iet-gtd.2018.6842DOI
5 
M. K. Park and S. H. Lim, “Fault Current Limiting and Magnetizing Characteristics of the Autotransformer Type SFCL,” The Korean Institute of Electrical and Electronic Material Engineers, vol. 18, no. 3, pp. 159-162, 2017. DOI:10.4313/TEEM.2017.18.3.159DOI
6 
T. H. Han and S. H. Lim, “Analysis on magnetizing characteristics of current limiting reactor using HTSC module,” Progress in Superconductivity and Cryogenics, vol. 20, no. 1, pp.15~18, 2018. DOI:10.9714/psac.2018.20.1.015DOI
7 
S. C. Ko, et al., “Analysis on fault current limiting and recovery characteristics of a flux-lock type SFCL with an isolated transformer,” Physica C: Superconductivity, vol. 484, pp. 263 266, 2013. DOI:10.1016/j.physc.2012.03.041DOI
8 
M. K. Park and S. H. Lim, “Fault current limiting and magnetizing characteristics of the autotransformer type SFCL,” Transactions on Electrical and Electronic Materials, vol. 18, no. 3, pp. 159-162, 2017. DOI:10.4313/TEEM.2017.18.3.159DOI
9 
J. S. Park, et al.,“Driving Current and Fault Current Limiting Characteristics of Three-Phase Autotransformer Type SFCL in Power Distributed System Connected with Induction Motor,” The Transactions of the Korean Institute of Electrical Engineers, vol. 73, no. 11, pp. 1917~1923, 2024. DOI:10.5370/KIEE.2024.73.11.1917DOI
10 
J. S. Park, et al., “Analysis on Starting Current Limiting Characteristics of Induction Motor Using a Three-Phase Reactor Type Superconducting Fault Current Limiter,” The Transactions of the Korean Institute of Electrical Engineers, vol. 73, no. 8, pp. 1311~1317, 2024. DOI:10.5370/KIEE.2024.73.8.1311DOI