Title A Study on the Application Effect of ESR Measurement Methods for DC Capacitor Fault Diagnosis of 3-level ANPC Inverter for Railway Vehicles
Authors 이현재(Hyun-Jae Lee) ; 김길동(Gil-Dong Kim) ; 이건복(Gun-Bok Lee) ; 손진근(Jin-Geun Shon)
DOI https://doi.org/10.5370/KIEEP.2023.72.3.172
Page pp.172-178
ISSN 1229-800X
Keywords 3-level ANPC Inverter; AC coupling-based ESR measurement; ESR(Equivalent Series Resistance); RMS-based ESR measurement.
Abstract This paper studies the effect of applying the ESR measurement method to diagnose DC-link capacitor failure of 3-level ANPC inverter for railway vehicles. Inverters use DC-link capacitors to keep the voltage constant, which is the factor with the highest failure rate compared to other components used in inverters. Accordingly, in this paper, in order to find a way to monitor the failure of the DC-link capacitor, ESR measurement methods were analyzed, and the effect was analyzed through a simulation experiment applied to a 3-level ANPC inverter. As a result, when measuring ESR by designing an analog filter using Op-Amp, the RMS-based ESR measurement method is effective. Conversely, when measuring ESR using digital filters, it is judged to be more effective to use the AC coupling-based ESR measurement method.