Title Calculation Method for the Transmitted Solar Irradiance Using the Total Horizontal Irradiance
Authors Byung-Ki Jeon ; Seung-Eun Lee ; Eui-Jong Kim
DOI https://dx.doi.org/10.6110/KJACR.2017.29.4.159
Page pp.159-166
ISSN 1229-6422
Keywords 수평면 전일사량 ; 직산 분리 모델 ; 가변 투과율 ; 기상데이터 Total horizontal irradiance ; Direct and diffuse split model ; Variable transmittance rate ; Weather data
Abstract The growing global interest in energy saving is particularly evident in the building sector. The transmitted solar irradiance is an important input in the prediction of the building-energy load, but it is a value that is difficult to measure. In this paper, a calculation method, for which the total horizontal irradiance that can be easily measured is employed, for the measurement of the transmitted solar irradiance through windows is proposed. The method includes a direct and diffuse split model and a variable-transmittance model. The results of the proposed calculation model are compared with the TRNSYS-simulation results at each stage for the purpose of validation. The final results show that the CVRMSE over the year between the proposed model and the reference is less than 30 %, whereby the ASHRAE guideline was achieved.