References

1 
2013, Article, Ministry of Land, Infrastructure and Transport, Law of building for facility, pp. 11Google Search
2 
Park JS, Kim HJ, 2012, A field study of occupant behavior and energy consumption in apartments with mechanical ventilation, Energy and Building, Vol. 50, pp. 19-25DOI
3 
Chang HJ, 2014, Heat recovery type natural ventilator, kr patent 10-1447097Google Search
4 
Cho YJ., Kang S. Y, 2004, ADPI Characteristics of Line Diffuser in a Room with Perimetric Heating Load, Proceeding of SAREK, Vol. 16, pp. 1204-1211Google Search
5 
Liu S, Novoselac A, 2015, Air Diffusion Performance Index (ADPI) of diffusers for heating mode, Building and Environment, Vol. 87, pp. 215-223Google Search
6 
Seok HT, Choi DH, Kim HJ, Yang JH, 2010, A Study on the Modeling and Analysis Method according to the Diffuser Shape, Journal AIK, Vol. 26, pp. 341-348Google Search
7 
Diffuser Performance Testing method, SPS-KARSE B 0008-170 : 2004Google Search
8 
Air Diffuser : 2011, KS B 6386Google Search
9 
ASHRAE, Handbook-HVAC Applications, Room air diffusion, This part is based on the findings as follows:Rydberg, J. and P. Norback, Air distribution and draft, 1949 ASHVE Transactions 55:225, Straub, H. E., S. F. Gilman, and S. Konzo, Distribution of air within a room for tear-round air conditioning-part 1, 1956, University of illinois Engineering Experiment Station bulletin, 435, and Straub, H. E., M. M. Chen, Distribution of air within a room for tear-round air conditioning-part 2, 1957, University of illinois Engineering Experiment Station bulletin, ASHRAE, Handbook, Vol. 442, pp. 57.5-57.10Google Search
10 
2010, Analytical determination and interpretation of thermal comfort using calculation of the PMV and PPD indices and local thermal comfort criteria, KS A ISO 7730Google Search
11 
2009, Thermal Environmental conditions for human occupancy, ASHRAE, standard 55Google Search
12 
Huang Y, Zhang H, 1997, commercial heating and cooling loads component analysis, Energy analysis program, Vol. 7Google Search
13 
Gwon YH, 2009, Air conditioning system with Combined type equipment, kr patent 10-0905296Google Search
14 
Chang HJ, 2002, Effects of air-conditioning and interior of office on indoor environment air conditioned by hybrid system utilizing natural ventilation, Journal AIK, Vol. 18, pp. 223-230Google Search
15 
2009, Method of Testing for Room Air Diffusion, ASHRAE, standard 113Google Search
16 
Park SI, Lee SH, Park HS, 2002, Computer simulation on the Thermal Environment by Diffusion Angle of Packaged Type Air Conditioner in Classroom, Journal AIK, Vol. 18, pp. 243-250Google Search
17 
Chang HJ, Lee HY, 2012, A Study on the Improvement of Indoor Thermal and Air Environment Made by Ceiling Cassette Type Cooling and Heating Unit in Classrooms, Journal KSES, Vol. 32, pp. 141-148DOI
18 
Ventilation Effectiveness Guidebook, REHVA, Vol. 2, pp. 23-26Google Search
19 
Indoor environmental Health, ASHRAE, Handbook-Fundamentals, pp. 10.1-10.9Google Search