KJACR
Korean Journal of
Air-Conditioning and Refrigeration Engineering
SAREK
Contact
ISSN : 1229-6422 (Print)
ISSN : 2465-7611 (Online)
http://journal.auric.kr/kjacr
Mobile QR Code
Korean Journal of Air-Conditioning and Refrigeration Engineering
ISO Journal Title
Korean J. Air-Cond. Refrig. Eng.
Open Access, Monthly
Open Access
Monthly
ISSN : 1229-6422 (Print)
ISSN : 2465-7611 (Online)
Online Submission
Main Menu
Main Menu
최근호
Current Issue
저널소개
About Journal
논문집
Journal Archive
목적 및 범위
Aims and Scope
편집위원회
Editorial Board
윤리규정
Research &
Publication Ethics
논문투고안내
Instructions to Authors
BM
(Business Model)
연락처
Contact Info
논문투고
Online-Submission
Journal Search
Home
Archive
2016-08
(Vol.28 No.08)
10.6110/KJACR.2016.28.8.316
Journal XML
XML
PDF
INFO
REF
References
1
Lee J. H., Lee D. Y., 2013, Experimental study of a counter flow regenerative evaporative cooler with finned channels, Int. Journal of Heat and Mass Transfer, Vol. 65, pp. 173-179
2
Duan Z., Zhan C., Zhang X., Mustafa M., Zhao X., Alimohammadisagvand B., Hasan A., 2012, Indirect evaporative cooling : Past, present and future potentials, Renewable Sustainable Energy Reviews, Vol. 16, No. 9, pp. 6823-6850
3
Maisotsenko V. S., Zimmerman A. B., Mikhaylova L. D., Pechorskaya I. M., 1977, Method of indirect- evaporative air cooling in household electrical appliances, Proceedings of World Electrotechnical Congress, Moscow, USSR.
4
Riangvilaikul B., Kumar S., 2010, An experimental study of a novel dew point evaporative cooling system, Energy and Buildings, Vol. 42, No. 5, pp. 637-644
5
Riangvilaikul B., Kumar S., 2010, Numerical study of a novel dew point evaporative cooling system, nergy and Buildings, Vol. 42, No. 11, pp. 2241-2250
6
Hasan A., 2010, Indirect evaporative cooling of air to a sub-wet bulb temperature, Applied Thermal Engineering, Vol. 30, No. 16, pp. 2460-2468
7
Bruno F., 2011, On-site experimental testing of a novel dew point evaporative cooler, Energy and Buildings, Vol. 43, No. 12, pp. 3475-3483
8
Zhan C., Duan Z., Zhao X., Smith S., Jin H., Riffat S., 2011, Comparative study of the performance of the M-cycle counter-flow and cross-flow heat exchangers for indirect evaporative coolingPaving the path toward sustainable cooling of buildings, Energy, Vol. 36, No. 12, pp. 6790-6805
9
Kozubal E., Woods J., Judkoff R., 2012, Development and Analysis of Desiccant Enhanced Evaporative Air Conditioner Prototype, National Renewable Energy Laboratory, Vol. TP-5500-54755.
10
Woods J., Kozubal E., 2013, A desiccant- enhanced evaporative air conditioner : Numerical model and experiments, Energ Convers Manage, Vol. 65, pp. 208-220
11
Cui X., Chua K. J., Yang W. M., Ng K. C., Thu K., Nguyen V. T., 2014, Studying the performance of an improved dew-point evaporative design for cooling application, Applied Thermal Engineering, Vol. 63, No. 2, pp. 624-633
12
Anisimov S., Pandelidis D., Jedlikowski A., Polushkin V., 2014, Performance investigation of a M(Maisotsenko) -cycle cross-flow heat exchanger used for indirect evaporative cooling, Energy, Vol. 76, pp. 593-606
13
Moshari S., Heidarinejad G., 2015, Numerical study of regenerative evaporative coolers for sub-wet bulb cooling with cross- and counter-flow configuration, Applied Thermal Enginerring, Vol. 89, pp. 669-683
14
Lee J. H., Choi B. S., Lee D. Y., 2013, Comparison of configurations for a compact regenerative evaporative cooler, Int. Journal of Heat and Mass Transfer, Vol. 65, pp. 192-198
15
Duan Z., Zhan C., Zhao X., Dong X., 2016, Experimental study of a counter-flow regenerative evaporative cooler, Building and Environment, Vol. 104, pp. 47-58
16
Lee D. Y., Lee J. W., Kang B. H., 2005, An experimental study on the effects of porous layer treatment on evaporative cooling of an inclined surface, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No. 1, pp. 25-32
17
Wang T. A., Reid R. L., 1996, Surface wettability effect on an indirect evaporative cooling system, ASHRAE Transactions, Vol. 102, No. 1, pp. 427-433