Mobile QR Code QR CODE : Korean Journal of Air-Conditioning and Refrigeration Engineering
Korean Journal of Air-Conditioning and Refrigeration Engineering

Korean Journal of Air-Conditioning and Refrigeration Engineering

ISO Journal TitleKorean J. Air-Cond. Refrig. Eng.
  • Open Access, Monthly
Open Access Monthly
  • ISSN : 1229-6422 (Print)
  • ISSN : 2465-7611 (Online)

References

1 
Wang W., Xiao J., Guo Q. C., Lu W. P., Feng Y. C., 2011, Field test investigation of the characteristics for the air source heat pump under two typical mal-defrost phenomena, Applied Energy, Vol. 88, pp. 4470-4480DOI
2 
Wang W., Feng Y. C., Zhu J. H., Li L. T., Guo Q. C., Lu W. P., 2013, Performances of air source heat pump system for a kind of mal-defrost phenomenon appearing in moderate climate conditions, Applied Energy, Vol. 112, pp. 1138-1145DOI
3 
Byun J. S., Jeon C. D., Jung J. H., Lee J., 2006, The application of photo-coupler for frost detecting in an air-source heat pump, Int. J. of Refrigeration, Vol. 29, pp. 191-198DOI
4 
Xiao J., Wang W., Zhao Y. H., Zhang F. R., 2009, An analysis of the feasibility and characteristics of photoelectric technique applied in defrost control, Int of Refrigerations, Vol. 32, pp. 1350-1357DOI
5 
Zhu J., Sun Y., Wang W., Ge Y., Li L., Liu J., 2015, A novel Temperature-Humidity-Time defrosting control method based on a frosting map for air-source heat pumps, International Journal of Refrogeration, Vol. 54, pp. 45-54DOI
6 
Jeon C. D., Kim D. S., Lee S. J., 2014, A feasibility study on defrost control method by using photoelectric sensor, Journal of the Korea Academia-Industrial cooperation Society, Vol. 15, No. 6, pp. 3389-3395DOI
7 
Jeon C. D., Kim D. S., 2014, Feasibility of the defrost control by photoelectric technology via comparison with the temperature differential defrosting method, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 26, No. 9, pp. 434-440DOI
8 
Jeon C. D., 2015, A development of the correlation for predicting the frost height in applying photoelectric sensors, Journal of the Korea Academia-Industrial cooperation Society, Vol. 16, No. 10, pp. 7138-7145DOI
9 
Xiao J., Wang W., Guo Q. C., Zhao Y. H., 2010, An experimental study of the correlation for predicting the frost height in applying the photoelectric technology, International Journal of Refrigeration, Vol. 33, pp. 1006-1014DOI
10 
Jeon C. D., Jung K. S., Frost sensing device and method, Korean Intellectual Property Office, Vol. Patent, No. 10-1085691Google Search
11 
KS C 9306 , 2002, Air conditioner.Google Search
12 
KS B 6275 , 2002, Reciprocating water-chillers.Google Search