2018-02
(Vol.30 No.02)
10.6110/KJACR.2018.30.2.083
Journal XML
XML
PDF
INFO
REF
References
1
Kim J. Y., Chang H. J., Jung Y. H., Cho K. M., Augenbroe G., 2017, Energy Conservation Effects of a Multi-Stage Outdoor Air Enabled Cooling system in a Data Center, Energy and buildings, Vol. 138, pp. 257-270
2
Park M. K., Chang H. J., 2017, A Study on the Regional Energy Conservation Effects of a Multi-Stage Outdoor Air Enabled Cooling System in a Data Center, Journal of the Korean Solar Energy Society, Vol. 37, No. 1, pp. 71-80
3
2011, ASHRAE datacom series : Thermal guidelines for data processing environments, ASHRAE
4
Patterson M. K., 2008, The Effect of Data Center Temperature on Energy Efficiency, IEEE 2008, 978-1-4244-1701-8, pp. 1167-1174
5
Fallah F., Pedram M., 2005, Standby and Active Leakage Current Control and Minimization in CMOS VLSI Circuits, IEICE Transactions on Electronics, Vol. E88-C, No. 4, pp. 509-519
6
Moss D., Bean J. H., 2011, Energy Impact of Increased Server Inlet Temperature, APC White paper 138.
7
Neudorfer J., 2016, Controlling supply air intake temperatures, Special reports of DATA CENTER Frontier.
8
Patankar S. V., 2010, Airfolow and cooling in a data center, Journal of Heat Transfer, Vol. 132, pp. 073001-1-073001-17
9
Ham S. W., Park J. S., Jeong J. W., 2015, Optimum supply air temperature ranges of various air-side economizers in a modular data center, Applied Thermal Engineering, Vol. 77, pp. 163-179
10
Cho J. K., Kim B. S., 2008, The cooling and air distribution systems for the optimal IT environment control in the internet data center, Journal of the architectural institute o Korea (Planning & design), Vol. 24, No. 2, pp. 313-320
11
Chang H. J., Kim J. Y., 2014, A Study on the Distribution of Airflow and Temperature in a Data center under the Various Conditions of Heat Generation Rates of Server Computers, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 26, No. 3, pp. 108-114
12
Chang H. J., Jung Y. H., Seo J. H., 2013, A study on the methodology of simulation on the distribution of airflow and temperature in a date center by utilizing porous boundary condition, J. of KIAEBS, KIAEBS, Vol. 권, No. 호, pp. 289-294
13
ANSYS FLUENT MANUAL, ANSYS.
14
Sharma R. K., Bash C. E., Patel C. D., 2002, Dimensionless parameters for evaluation of thermal design and performance of large scale data centers, Proceedings of AIAA 2002-3091, American Institute of Aeronautics and Astronautics Conference.
15
Cho J. K., Kim B. S., 2011, Evaluation of air management system’s thermal performance for superior cooling efficiency in highdensity data centers, Energy and Buildings, pp. 2145-2135
16
Herrlin M. K., 2005, Rack cooling effectiveness in data centers and telecom central offices: the rack cooling index (RCI), ASHRAE Transactions, Vol. 111, No. 2, pp. 1-11
17
Herrlin M. K., 2007, Improved data center energy efficiency and thermal performance by advanced airflow analysis, in : Proceedings of Digital Power Forum, pp. 10-12