Mobile QR Code QR CODE : Korean Journal of Air-Conditioning and Refrigeration Engineering
Korean Journal of Air-Conditioning and Refrigeration Engineering

Korean Journal of Air-Conditioning and Refrigeration Engineering

ISO Journal TitleKorean J. Air-Cond. Refrig. Eng.
  • Open Access, Monthly
Open Access Monthly
  • ISSN : 1229-6422 (Print)
  • ISSN : 2465-7611 (Online)

References

1 
Kim J. H., 2018, Ventilation and filtration control strategy considering indoor and outdoor particle environmental conditions of apartment building, Ph.D. Thesis, Seoul national university, Seoul, Korea.Google Search
2 
Franck U., Odeh S., Wiedensohler A., Wehner B., Herbarth O., 2011, The effect of particle size on cardiovascular disorders-the smaller the worse, Science of the Total Environment, Vol. 409, No. 20, pp. 4217-4221DOI
3 
Hoek G., Krishnan R. M., Beelen R., Peters A., Ostro B., Brunekreef B., Kaufman J. D., 2013, Long-term air pollution exposure and cardio-respiratory mortality : a review, Environmental health, Vol. 12, No. 1, pp. -DOI
4 
Kim K.-H., Kabir E., Kabir S., 2015, A review on the human health impact of airborne particulate matter, Environment international, Vol. 74, pp. 136-143DOI
5 
Shah A. S. V., Lee K. K., McAllister D. A., Hunter A., Nair H., Whiteley W., Langrish J. P., Newby D. E., Mills N. L., 2015, Short term exposure to air pollution and stroke : systematic review and meta-analysis, bmj, Vol. 350DOI
6 
, https://me.go.kr/cleanair/sub02.do(Acessed on October 13 2019).
7 
Jamriska M., Morawska L., Ensor D. S., 2003, Control strategies for sub-micrometer particles indoors : model study of air filtration and ventilation, Indoor Air, Vol. 13, No. 2, pp. 96-105DOI
8 
Ministry of Land Infrastructure and Transport, 2017, Rules on the Building Equipment Standards, etc., MLIT criteria 2017-467Google Search
9 
, https://www.ktb.co.kr/common/download.jspx?cmd=viewPDF(Acessed on November 12 2019).
10 
Base S. H., Jeong M. H., 2017, Ventilation System for Apartment Houses with Filtering mode, Korea Institute of Architectural sustainable environment and building systems, Vol. 11, No. 1, pp. 23-30Google Search
11 
Cho W., Song D., Hwang S., Yun S., 2015, Energy-efficient ventilation with air-cleaning mode and demand control in a multi-residential building, Energy and Buildings, Vol. 90, pp. 6-14DOI
12 
Han K., Zhang J. S., Guo B., 2014, A novel approach of integrating ventilation and air cleaning for sustainable and healthy office environments, Energy and Buildings, Vol. 76, pp. 32-42DOI
13 
Hänninen O., Asikainen A., 2013, fficient reduction of indoor exposures-Health benefits from optimizing ventilation, filtration and indoor source controls, ISBN 978-952-245-821-6, The Report 2013-2.Google Search
14 
Liu H., Lee S., Kim M., Shi H., Kim J. T., Wasewar K. L., Yoo C., 2013, Multi-objective optimization of indoor air quality control and energy consumption minimization in a subway ventilation system, Energy and Buildings, Vol. 66, pp. 553-561DOI
15 
Orme M., Liddament M. W., Wilson A., 1998, Numerical data for air infiltration and natural ventilation calculations, Air Infiltration and Ventilation Centre Coventry, UKDOI
16 
Tamura G. T., Jeong M. H., 2008, Smoke movement and control in high-rise buildings, National Fire Protection Association.Google Search
17 
Park S. W., Munkhbat U., Song D. S., 2019, An Analysis of Infiltration Characteristics of Outdoor Particulate Matter according to Building Airtightness Performance, Proceeding of KSES 2019 Fall Annual Conference.Google Search
18 
Wallace L., 1996, Indoor particles : a review, Journal of the Air & Waste Management Association, Vol. 46, No. 2, pp. 98-126DOI
19 
Ferro A. R., Kopperud R. J., Hildemann L. M., 2004, Source strengths for indoor human activities that resuspend particulate matter, Environmental Science & Technology, Vol. 38, No. 6, pp. 1759-1764DOI
20 
He C., Morawska L., Hitchins J., Gilbert D., 2004, Contribution from indoor sources to particle number and mass concentrations in residential houses, Atmospheric Environment, Vol. 38, No. 21, pp. 3405-3415DOI
21 
ASHRAE , 2016, Standard 62.1-2016 : ventilation for acceptable indoor air quality, Atlanta, GA : American Society of Heating, Refrigerating and Air Conditioning EngineersGoogle Search
22 
ASHRAE , 2012, Standard 52.2 : Method of Testing General Ventilation Air-Cleaning Devices for Removal Efficiency by Particle Size, Atlanta, GA : American Society of Heating, Refrigerating and Air Conditioning EngineersGoogle Search