Mobile QR Code QR CODE : Korean Journal of Air-Conditioning and Refrigeration Engineering
Korean Journal of Air-Conditioning and Refrigeration Engineering

Korean Journal of Air-Conditioning and Refrigeration Engineering

ISO Journal TitleKorean J. Air-Cond. Refrig. Eng.
  • Open Access, Monthly
Open Access Monthly
  • ISSN : 1229-6422 (Print)
  • ISSN : 2465-7611 (Online)

References

1 
Lee, S., Lee, W., Roh, J., Lee, S., Kim, E., and Yeo, M., 2024, Post-occupancy evaluation on temporary negative pressure isolation wards with portable high-efficiency particulate air filter units used during the COVID-19 pandemic in South Korea, American Journal of Infection Control, Vol. 52, No. 12, pp. 1403-1411.DOI
2 
Shin, H. W., Kim, D. W., Kim, J. M., Jung, H. B., and Kang, D. H., 2023, Analysis of Minimum Airflow Differences between Supply and Exhaust Air according to Airtightness of Rapidly Converted Temporary Negative Pressure Isolation Rooms, Journal of The Korea Institute of Healthcare Architecture, Vol. 29, No. 4, pp. 69-77.DOI
3 
Seo, C., Kim, Y., Choi, H., and Choi, J., 2021, A Study on the Improvement of the Performance Standard for Portable Negative Pressure Unit in the Military Hospital for dedicated National Infectious Disease, The Journal of the Korean Military Medicine, Vol. 52, No. 1, pp. 27-37.URL
4 
Niu, J. and Tung, T. C. W., 2008, On-Site Quantification of Re-Entry Ratio of Ventilation Exhausts in Multi-Family Residential Buildings and Implications, Indoor Air, Vol. 18, No. 1, pp. 12-26.DOI
5 
Wu, Y., Tung, T. C. W., and Niu, J., 2016, On-Site Measurement of Tracer Gas Transmission between Horizontal Adjacent Flats in Residential Building and Cross-Infection Risk Assessment, Building and Environment, Vol. 99, pp. 13-21.DOI
6 
Wu, Y. and Niu, J., 2016, Assessment of Mechanical Exhaust in Preventing Vertical Cross-Household Infections Associated with Single-Sided Ventilation, Building and Environment, Vol. 105, pp. 307-316.DOI
7 
Park, D., Yeo, M., Lee, S., Lee, W., and Roh, J., 2024, Artificial intelligence low-noise mobile negative pressure device with sterilization and deodorization performance and its control method, Korean Patent Application 10-2024-0086508.URL
8 
Korea Air Cleaning Association, 2021, SPS-C KACA 0031-7423:2021 (SPS-C KACA 0031-7423).URL
9 
Park, D., Yeo, M., Lee, S., Lee, W., and Roh, J., 2024, Separation-multi type portable HEPA filter unit and its control method, Korean Patent Application 10-2024-0066041.URL
10 
Testo, n.d., Instruction manual testo 816-1.pdf, Retrieved from https://static.testo.com/image/upload/Instruction-manual-and-Software/Instruction-manuals/testo-816-1-instruction-manual.pdf.URL
11 
American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE), 2019, ASHRAE Handbook - HVAC Applications (SI Edition), Chapter 49, Atlanta, GA.URL
12 
Naish, D. A., Tan, A. C. C., Nur Demirbilek F., 2013, Speech interference and transmission on residential balconies with road traffic noise, The Journal of the Acoustical Society of America, Vol. 133, No. 1, pp. 210-226.DOI
13 
Xu, G., Jong E. C., Luxbacher, K. D., and McNair, H. M., 2016, Effective Utilization of Tracer Gas in Characterization of Underground Mine Ventilation Networks, Process Safety and Environmental Protection, Vol. 99, pp. 1-10.DOI
14 
Long, M., 2014, Architectural Acoustics, 2nd ed, Academic Press, pp. 81-127.URL