References

1 
Yang, S. K., Kang, Y. H., Kim, J. H., Lee, E. Y., Kim, J. Y., and Ahn, Y. C., 2023, Experimental Study of Fouling Characteristics According to The Fin Shape of Finned Tube Type Heat Exchanger, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 35, No. 11, pp. 549-558.DOI
2 
Marner, W. J., MacDavid, K. S., and muzio, L. J., 1989, Development of a gas side fouling measuring device, National Heat Transfer Conference, Vol. 108, pp. 305-414.URL
3 
Epstein, N., 1988, General Thermal Fouling Models, Fouling Science and Technology, pp. 15-30DOI
4 
Ahn, Y. C., Cho, J. M., Shin, H. S., Hwang, Y. J., Lee, C. G., Lee, J. K., Lee, H. U., and Kang, T. W., 2003, An Experimental Study of the Air-side Particulate Fouling in Fin-and-Tube Heat Exchangers of Air Conditioners, Korean Journal of Chemical Engineering, Vol. 20, No. 5, pp. 873-877.DOI
5 
Kern, D. Q. and Seaton, R. E., 1959, A theoretical analysis of thermal surface fouling, British Chemical Engineering, Vol. 14, No. 3, pp. 258-262.URL
6 
Ahn, Y. C. and Lee, J. K., 2005, Modeling of the Air-side Particulate Fouling in Finned-Tube Heat Exchangers of Air Conditioners using Accelerated Particle-Loading System, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No. 3, pp. 262-267.URL
7 
Bell, I. H. and Groll, E. A., 2011, Air-side particulate fouling of microchannel heat exchangers: Experimental comparison of air-side pressure drop and heat transfer with plate-fin heat exchanger, Applied Thermal Engineering, Vol. 31, No. 5, pp. 742-749.DOI
8 
Lankinen, R., Suihkonen, J., and Sarkomaa, P., 2003, The effect of air side fouling on thermal‐hydraulic characteristics of a compact heat exchanger, International journal of energy research, Vol. 27, No. 4, pp. 349-361.DOI
9 
Chae, H. M., Kwon, J. T., Cha, D. A., and Kwon, O. K., 2014, The Measurements of Ball Recovery Rate for the Cleaning Apparatus in Plate Heat Exchanger Using Ceramic Ball, Journal of Power System Engineering, Vol. 18, No. 1, pp. 38-44.DOI
10 
Baek, S. M., Choi, W. J., Yoon, J. I., and Seol, W. S., 2010, Characteristics of Decrease Effect in Fouling on Plate Heat Exchanger Using Air Bubble, Journal of Power System Engineering, Vol. 14, No. 1, pp. 22-26.URL
11 
Pak, B. C., Groll, E. A., and Braun, J. E., 2005, Impact of Fouling and Cleaning on Plate Fin and Spine Fin Heat Exchanger Performance, Ashrae Transactions, Vol. 111, No. 1, pp. 496-504.URL
12 
Ahn, Y. C., Shin, H. S., Hwang, Y. J., Lee, C. K., Lee, J. K., Lee, H. U., Ahn, S. P., Youn, D. H., Ha, S. C., and Kang, T. W., 2003, Characteristics of the Air-Side Particulate Fouling Materials in Finned-Tube Heat Exchangers of Air Conditioners, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 15, No. 7, pp. 611-617.DOI