Title |
Fault Detection of BLDC Motor Drive Based on Operating Characteristic |
Authors |
Jung-Dae Lee ; Byoung-Gun Park ; Tae-Sung Kim ; Ji-Su Ryu ; Dong-Seok Hyun |
Keywords |
BLDC Motor Drive; Fault Detection; Open-Circuit Faults; Inverter |
Abstract |
In this paper, we proposed the isolated multi-level inverter using 3-phase transformers. It makes possible to use a single DC power source due to employing low frequency transformers. In this inverter, the number of transformer could be reduced comparing with an exiting 3-phase multi-level inverter using single phase transformer. Also, using phase angle control method with switching frequency equal to output fundamental frequency, harmonics component of output voltage and switching losses can be reduced. Finally, we made a prototype inverter to clarify the proposed electric circuit and reasonableness of control signal. |