Abstract This paper proposes the battery charging algorithm for small-scale wind power generator using three phase PWM converter. it is impossible to control output power of the converter in over wind speed region since back EMF of PMSG is higer than battery voltage. Therefore, battery charging algorithm is proposed to expand battery charging over wind speed region. The suggested method is using the q-axis current for battery charging in the rated wind speed region. In the over wind speed region after it lower back EMF of PMSG using d-axis current it can control output power of the converter. The validity of the proposed algorithm are verified by experiments.