JKSMI
Journal of the Korea Institute for
Structural Maintenance and Inspection
KSMI
Contact
Open Access
Bi-monthly
ISSN : 2234-6937 (Print)
ISSN : 2287-6979 (Online)
http://journal.auric.kr/jksmi/
Mobile QR Code
Journal of the Korea Concrete Institute
J Korea Inst. Struct. Maint. Insp.
Indexed by
Korea Citation Index (KCI)
Main Menu
Main Menu
About Journal
Aims and Scope
Subscription Inquiry
Editorial Board
For Contributors
Instructions For Authors
Ethical Guideline
Crossmark Policy
Submission & Review
Archives
Current Issue
All Issues
Journal Search
Home
All Issues
2014-01
(v.18 n.1)
mi.2014.18.1.101
Journal XML
XML
PDF
INFO
REF
References
1
(1999), Design Consideration for Steel Fiber Reinforced Concrete, ACI 544.4R
2
(1997), Shear tests of fiber concrete beams without stirrups, ACI Structural Journal, 94(1), 68-76.
3
(2003), A Study on Evaluation of Crack Resistance in Chemically Prestressed Mortar, Master Thesis, Yonsei University, (in Korean), 58-72.
4
(2003), A study on fracture characteristics of chemically prestressed mortar, KCI Spring Conference, (in Korean), 15(1), 828-832.
5
(1994), Polymorphism of Calcium Sulfoaluminate (Ca4Al6O16·O3) and its solid solution, Advances in Cement Research, 22(6), 57-60.
6
(2012), Seismic performance evaluation of reinforced concrete columns by applying steel fiber-reinforced mortar at plastic hinge region, Journal of the Korea Concrete Institute, (in Korean), 24(3), 241-248.
7
(1999), A Field Application of Non-Shrinkage High Strength Concrete UsingCSA Expansive Additives, Proceedings of KCI, (in Korean), 11(2), 77-80.
8
(1998), A Study on the Properties of High Performance Concrete UsingCSA Expansive Additivies, Journal of Architecture Institute of Korea, (in Korean), 14(11), 66-70.
9
(2011), Study on the Estimation of Drying Shrinkage of the Concrete Using CSA Expansive Additive Based on Regression Analysis, Journal of Architecture Institute of Korea, (in Korean), 27(9), 109-116.
10
(2011), The effect of steel-fiber contents on the compressive stress-strain relation of ultra high performance cementitious composites (UHPCC), Journal of the Korea Concrete Institute, (in Korean), 23(1), 67-75.
11
(2003), A Study on Evaluation of Crack Resistance in Chemically Prestressed Steel Fiber Reinforced Concrete, Master Thesis, Yonsei University, (in Korean)
12
(2005), Combined effect of expansive and shrinkage reducing admixtures to obtain stable and durablemortars, Cement and Concrete Research, (in Korean), 35(2), 2244-2251.
13
(2001), Effect of Multi-Axial Restraint against Cracking Resistance in BendingMember of Expansive Concrete, Proceeding of Japan Concrete Institute, 23(3), 589-594.
14
(1998), Expansive admixtures (mainly ettringite), Cement and Concrete Composites, 20(2-3), 163-170.
15
(2006), Seismic analysis of underground reinforced concretestructures considering elasto-plastic interface element with thickness, Engineering Structures, 28(2), 1122-1131.
16
(1991), Nonlinear Analysis and Constitutive Models of Reinforced Concrete, 102-181.
17
(2001), Chemically prestressed precast concrete box culvert with expansive additives, Journal of the Korea Concrete Institute, 13(1), 43-51.
18
(2002), Cracking Behaviors of chemical prestressed reinforced concrete members, (in Japanese), 5-13.
19
(1994), Nonlinear Static and Dynamic Analysis for Underground Reinforced Concrete, Ph.D. Dissertation, (in Japanese), 22-36.
20
(2004), A Study on Crack Behavior of Chemically Prestressed Steel Fiber Reinforced Concrete, KCI Fall Conference, (in Korean), 16(2), 121-124.
21
(2012), Analysis technique for autogenous shrinkage on high performance-concrete with mineral and chemical admixtures, Construction and Building Materials, 34(9), 1-10.