Mobile QR Code QR CODE

Journal of the Korea Concrete Institute

J Korea Inst. Struct. Maint. Insp.
  • Indexed by
  • Korea Citation Index (KCI)

References

1 
Ministry of Land, (2015), Standard floor finishing and structures for interlayer noise prevention, Governing City: Ministry of Land, Infrastructure and Transport., 319Google Search
2 
Jeon., (2010), A quantification model of overall dissatisfaction with indoor noise environment in residential buildings, Applied Acoustics, no. 7, 914-921.DOI
3 
Cha, S. (2014), The management system and effect of floor noise at apartment houses, In Joint Conference by Korean Society for Noise and Vibration Engineering.Google Search
4 
Lee, J. W., Park, H., Yun, H., Jung, D., Lee, K. M., Kwon, M. (2017), Procedure of noise measurement method for noise standard and improvement plan, In Joint Conference by Korean Society for Noise and Vibration Engineering, 168-170.Google Search
5 
Park, S. H., Lee, P. J. (2017), Effects of floor impact noise on psychophysiological responses, Building and Environment, 116, 174-181.DOI
6 
Schiavi, A. (2018), Improvement of impact sound insulation: A constitutive model for floating floors, Applied Acoustics, 129, 64-71.DOI
7 
Martins, C., Santos, P., Almeida, P., Godinho, L., Dias, A. (2015), Acoustic performance of timber and timber-concrete floors, Construction and Building Materials, 101, 684-691.DOI
8 
Faustino, J., Pereira, L., Soares, S., Cruz, D., Paiva, A., Varum, H., , et al. (2012), Impact sound insulation technique using corn cob particleboard, Construction and Building Materials, 37, 153-159.DOI
9 
D’alessandro, F., Asdrubali, F., Baldinelli, G. (2014), Multi- parametric characterization of a sustainable lightweight concrete containing polymers derived from electric wires, Construction and Building Materials, 68, 277-284.DOI
10 
Beak, G.O. (2015), Analysis of Heavy-weight Floor Impact Noise and Vibration of Concrete Slabs in a Residential Building, Proceedings of The 2015 World Congress on Advances in Civil, Environmental, and Materials Research(ACEM15), Incheon, August.Google Search
11 
Lee, Y. J., Jeong, Y. (2016), The objective and subjective evaluation of heavy-weight floor impact noise in box frame-type structures, Proceedings of the INTER-NOISE 2016 HamburgGoogle Search
12 
Bang, J. D. (2013), An Investigation Study on the R&D Trends for Mitigation Technologies of Floor Impact Noise of Apartment House, Land and Housing Institute Report(2013-15)Google Search
13 
Chun, Y.S. (2015), Development of technologies for reducing floor impact noise in new residental apartments considering spatial characteristics, Land and Housing Institute, National Project Report(2nd year)Google Search
14 
Korea Standards Association, (2012), F2810-2: 2012 (Field measurement of impact sound insulation of floors-Part 2: Method using standard heavy impact source), Seoul: Korea Standards Association.Google Search
15 
Korea Standards Association, (2007), F2863-2: 2007 (Rating of floor impact sound insulation for impact source in buildings and of building elements-Part 2: Floor impact sound insulation against standard heavy impace source), Seoul: Korea Standards Association.Google Search
16 
(2014), LMS Virtual.Lab Acoustic software, SIEMENSGoogle Search