Mobile QR Code QR CODE

Journal of the Korea Concrete Institute

J Korea Inst. Struct. Maint. Insp.
  • Indexed by
  • Korea Citation Index (KCI)

References

1 
ABAQUS (2018), Dassault System Simulia Corp., Analysis User’s Manual. Version 6.14.URL
2 
ACI Committee 437, Load Tests of Concrete Structures: Methods, Magnitude, Protocols, and Acceptance Criteria (ACI 437.1R-07).Google Search
3 
Chang, J., Kwon, M., Kim, J., and Joo, C. (2012), NumericalStudy for Seismic Strengthening of RC columns Using Fiber Reinforced Plastic Composite, The Korea Institute for Structural Maintenance and Inspection, https://doi.org/10.11112/jksmi.2012.16.3.117DOI
4 
Hur, M. W., Chun, Y. S., Hwang, J. S., and Kim, J. H. (2015), Seismic Capacity of Non-seismic Designed RC Framed Building Retrofitted by Double I-type Metallic Damper, The Korea Institute for Structural Maintenance and Inspection, 19(6), 010-017, https://doi.org/10.11112/jksmi.2015.19.6.010DOI
5 
Jeong, D. S., Kim, G. M., Kim, B. W., Kim, W. S., and Kwak, Y. K. (2020), Study of the Mechanical Properties of Fiber Reinforced Concrete According to Inorganic Fiber Combination, Journal of the Korean Society for Advanced Composite Structures, 11(3), 16-24, https://doi.org/10.11004/kosacs.2020.11.3.016DOI
6 
Jung, J. S., and Lee, K. S. (2018), A Seismic Capacity of R/C Building Damaged by the 2016 Gyeongju Earthquake Based on the Non- linear Dynamic Analysis, The Korea Institute for Structural Maintenance and Inspection, 22(1), 137-146, https://doi.org/10.11112/jksmi.2018.22.1.137DOI
7 
Jung, H. C., Jung, J. S., and Lee, K. S. (2019), Seismic Performance Evaluation of Internal Steel Frame Connection Method for Seismic Strengthening, Journal of the Korea Concrete Institute, 31(1), 79-88, https://doi.org/10.4334/JKCI.2019.31.1.079DOI
8 
Kim, J. S., Kwon, M. H., Seo, H. S., Lim, J. H., and Kim, D. Y. (2013a), Analytical Study for Optimal Reinforcement Amount and Development of FRP Seismic Reinforcement that can be Emergency Construction, The Korea Institute for Structural Maintenance and Inspection, 17(5), 136-145, https://doi.org/10.11112/jksmi.2013.17.5.1DOI
9 
Kim, J. S., Kwon, M. H., Jung, W. Y., and Limkatanyu, S. (2013b), Seismic performance evaluation of RC columns reinforced by GFRP composite sheets with clip connectors, Constructinand Building Materials, 43, 563-574. https://doi.org/10.1016/j.conbuildmat.2013.02.023DOI
10 
Kim, S. K., Park, J. K., Han, S. H., Kim, B. C., and Jang, I. Y. (2014a), Study on Reinforcement Effect of Circular RC Columns by Helical Bar Under Cyclic Lateral Load, The Korea Institute for Structural Maintenance and Inspection, 18(1), 048-058, https://doi.org/10.11112/jksmi.2014.18.1.048DOI
11 
Kim, J. S., Seo, H. S., Lim, J. H., and Kwon, M. H. (2014b), An Performance Evaluation of Seismic Retrofitted Column Using FRP Composite Reinforcement for Rapid Retrofitting, Journal of the Korea Concrete Institute, 26(1), 47~55, http://dx.doi.org/10.4334/JKCI.2014.26.1.047DOI
12 
Kwon, M. H., Seo, H. S., and Kim, J. S. (2016), Seismic Performance of RC-Column Wrapped with Velcro, Structural Engineering and Mechanics, 58(2), 379-395.URL
13 
Kown, M. H., Shing, P. B., Mallare, C., and Restrepo, J. (2011), Seismic Resistance of RC Bent Caps in Elevated Mass Transit Structures, Earthquake Spectra, 27(1), 67-88, https://doi.org/10.1193/1.3533471DOI
14 
Lee, J., and Fenves, G. L. (1998), Plastic-Damage Model For Cyclic Loading of Concrete Structure, Journal of Engineering Mechanics, ASCE, 124(8), 892-900. https://doi.org/10.1016/j.proeng.2011.07.057DOI
15 
Lee, P. S., and Noh, H. C. (2007), On the Finite Element Analysis of Shell Structures, Korean Society of Civil Engineers, 27(3A), 277-289.URL
16 
Lee, D. J., Kim S. W., Kim K. M., and Kim J. S. (2020a) Compressive Behavior of Concrete Specimen Reinforced by Velcro, Journal of the Korean Society for Advanced Composite Structures, 11(5), 15-21, https://doi.org/10.11004/kosacs.2020.11.5.015DOI
17 
Lee, H., Cho, J., Lee, S. G., Lee, S. H., and Hong, K. J. (2020b), Effect of BFRP Wrapping on Seismic Behavior of Rectangular RC Columns, Journal of the Korea Institute for Structural Maintenance and Inspection, 24(6), 153-160, https://doi.org/10.11112/jksmi.2020.24.6.153DOI
18 
Lubliner, J., Oliver, J., Oller, S., and Onate, E. (1989), A Plasticdamage Model for Concrete, International Journal of Solids and Structures, 25(3), 1989, 299-326, https://doi.org/10.1016/0020-7683(89) 90050-4DOI
19 
Hong, G. H. (2008), Construction Method Improvement of the FRP-plate Strengthening Method using the Velcro, The Korea Institute for Structural Maintenance and Inspection, 12(6), 225-232.URL