Mobile QR Code QR CODE

Journal of the Korea Concrete Institute

J Korea Inst. Struct. Maint. Insp.
  • Indexed by
  • Korea Citation Index (KCI)

References

1 
Rossi, P. (1992), Mechanical behaviour of metal-fibre reinforced concretes, Cement and Concrete Composites, 14(1), 3-16.DOI
2 
Yazıcı, Ş., İnan, G., Tabak, V. (2007), Effect of aspect ratio and volume fraction of steel fiber on the mechanical properties of SFRC, Construction and Building Materials, 21(6), 1250-1253.DOI
3 
Jang, S. J., Yun, H. D. (2018), Combined effects of steel fiber and coarse aggregate size on the compressive and flexural toughness of high-strength concrete, Composite Structures, 185, 203-211.DOI
4 
Abbass, W., Khan, M. I., Mourad, S. (2018), Evaluation of mechanical properties of steel fiber reinforced concrete with different strengths of concrete, Construction and Building Materials, 168, 556-569.DOI
5 
Chen, G., Gao, D., Zhu, H., Yuan, J. S., Xiao, X., Wang, W. (2021), Effects of novel multiple hooked-end steel fibres on flexural tensile behaviour of notched concrete beams with various strength grades, Structures, 33, 3644-3654.DOI
6 
Kim, D. H., Jang, S. J., Kim, S. W., Park, W. S., Yun, H. D. (2021), Effect of hooked-end steel fiber volume fraction and aspect Ratio on flexural and compressive properties of concrete, Journal of the Korea institute for structural maintenance and inspection, 25(3), 40-47.DOI
7 
Nataraja, M. C., Dhang, N., Gupta, A. P. (1999), Stress–strain curves for steel-fiber reinforced concrete under compression, Cement and Concrete Composites, 21(5-6), 383-390.DOI
8 
Tiberti, G., Trabucchi, I., AlHamaydeh, M., Minelli, F., Plizzari, G. (2017), Crack control in concrete members reinforced by conventional rebars and steel fibers, In IOP Conference Series: Materials Science and Engineering, 246(1), 012008-.DOI
9 
(2013), FIB, in: fib Model Code for concrete structures 2010, International Federation for structural concrete (fib), LausanneDOI
10 
KS F 2403., (2014), Standard Test Method of Making and Curing Concrete Specimens, Korean Standards Association (in Korean), -.Google Search
11 
European Committee for Standardization., (2005), EN 14651 test method for metallic fibered concrete—Measuring the flexural tensile strength (limit of proportionality (LOP), residual), residual, Brussels, Belgium.Google Search
12 
Vandewalle, L., Nemegeer, D., Balazs, L., Barr, B., Barros, J., Bartos, P., Walraven, J. (2003), RILEM TC 162-TDF: Test and design methods for steel fibre reinforced concrete'-sigma- epsilon-design method-Final Recommendation, Materials and Structures, 36(262), 560-567.DOI
13 
RILEM Committee on Fracture Mechanics of Concrete-Test Methods (RILEM 50-FMC), (1985), 16 Determination of the fracture energy of mortar and concrete by means of three-point bend test 17 on notched beams, Mater Struct, 18, 285290Google Search