Mobile QR Code QR CODE

Journal of the Korea Concrete Institute

J Korea Inst. Struct. Maint. Insp.
  • Indexed by
  • Korea Citation Index (KCI)

References

1 
Sumitro, S., Hida, K., Diouron, T. Le. (2003), Structural Health Monitoring Paradigm for Concrete Structures, 28th Conference on Our World in Concrete & Structures, CI-PREMIER PTE LTD, Singapore, 525-532.URL
2 
Lee, S. C., Choi, S. Y., Shin, K. J., Kim, J. M., Lee, H. W. (2015), Measurement of Transfer Length for a Seven-Wire Strand with FBG Sensors, Journal of Computational Structural Engineering Institute of Korea, 28(6), 707-714.DOI
3 
Wang, M. L., Chen, Z. (2000), Magneto-Elastic Permeabitilty Measurement for Stress Monitoring in Steel Tendons and Cables, Proc. of the SPIE 7th Annual Symposium on Smart Structures and Materials, Health Monitoring of the Highway Transportation Infrastructure, 3995, 492-500.Google Search
4 
Measures, R. M., Alavie, A. T., Maaskant, R., Ohn, M., Karr, S., Huang, S. (1994), Bragg Grating Structural Sensing System for Bridge Monitoring, Proc. of the SPIE 1994, 2294, 53-60.DOI
5 
Maaskant, R., Alabie, T., Measures, R. M., Tadros, G., Rizkalla, S. H., Guha-Thakurta, A. (1997), Fiber-Optic Bragg Grating Sensors for Bridge Monitoring, Cement & Concr. Compos., 19, 21-33.DOI
6 
Kim, H. W., Kim, J. M., Choi, S. Y., Park, S. Y., Lee, H. W. (2015), Long Term Monitoring of Prestressing Tension Force in Post –Tension UHPC Bridge using Fiber Optical FBG Sensor, Journal of Computational Structural Engineering Institute of Korea, 28(6), 699-706.DOI
7 
Roller, J. J., Russell, H. G., Brucr Jr, R. N., Alaywan, W. R. (2011), Evaluation of Prestress Losses in High-strength Concrete Bulb-tee Girders for the Rigolets Pass Bridge, PCI J., 56(1), 110-134.URL
8 
Inaudi, D. (1994), Low-Coherence Deformation Sensors for the Monitoring of Civil Engineering Structures, Sens. & Actuators A, 44, 125-130.DOI
9 
Idriss, R. L. (2001), Monitoring of a High Performance Prestressed Concrete Bridge with Embedded Optical Piber Sensors during Fabrication, Construction and Service, Proceedings of the 9th International Conference Structural Faults Repair, London.Google Search
10 
Gauthuer, R. C., Ross, C. (1997), Theoretical and experimental considerations for a single-mode fiber-optic bend-type sensor, Applied Optics, 36(25), 6264-6273.DOI
11 
Marcuse, D. (1976), Curvature loss fomula for optical fibers, Journal of Optical Society of America, 66(3), 216-220.DOI
12 
Donlagic, D., Culshaw, B. (2000), Propagation of the fundamental mode in curved graded index multimode fiber and its application in sensor system, Journal of Lightwave Technology, 18(3), 334-342.URL
13 
Yoo, J. A., Jo, J. H., Kwon, I. B. (2004), Multiplexed Bend Loss Type Single-Mode Fiber-Optic Displacement Sensor Using Reflection Signals Generated at Optical Connectors, Journal of the Optical Society of Korea, 15(5), 415-422.DOI
14 
Snyder, A. W., Love, J. D. (1983), Optical Waveguide Theory, Chapman and Hall, London, 250-290.Google Search
15 
Lee, K. H., Ahn, B. J., Kim, D. H. (2011), Fiber Optic Displacement Sensor System for Structural Health Monitoring, Journal of the Korean Society for Nondesturctive Testing, 31(4), 374-381.URL
16 
Kim, Y. B., Lee, K. S., Watanabe, K., Sasaki, H., Choi, Y. W. (2007), Hetero-core Spliced Fiber Optical Sensing System for an Environment Monitoring, Journal of Ocean Engineering and Technology, 21(3), 46-51.URL
17 
Park, K. T. (2007), The State of the Art on Bridge Monitoring by using Fiber Optic Sensor, Journal of the Korea Institute for Structural Maintenance and Inspection, 11(5), 3-9.Google Search
18 
Park, Y. S., Song, K. T., Jin, S. S., Park, Y. H., Kim, S. T. (2020), Optical Fiber-Based Hybrid Nerve Measurement System for Static and Dynamic Behavior of Structures, Journal of the Korea Institute for Structural Maintenance and Inspection, 24(2), 33-40.DOI