Mobile QR Code QR CODE

Journal of the Korea Concrete Institute

J Korea Inst. Struct. Maint. Insp.
  • Indexed by
  • Korea Citation Index (KCI)

References

1 
AIJES-V001-2004:Guildlines of the valuation of habitability to building vibration, Architectural Institute of Japan(AIJ) (in Japanese), 2004.URL
2 
Chopra, A. K. (2016), Dynamics of Structures 5th edn., PearsonURL
3 
Elias, P., Villot, M. (2012), Review of existing standards, regulations and guidelines, as well as laboratory and field studies concerning human exposure to vibration, Railway-Induced Vibration Abatement Solutions(RIVAS) Collaborative project, WP1(03).URL
4 
ESCO RTS, http://www.enrtech.co.kr.URL
5 
Ham, K. W., Lee, K. J., and Suh, Y. P. (2006), Experimental Study on Vertical Reduction Effectiveness of Main Control Room of Npp using 3-Dimensional Isolation System, Spring conference journal of EESK, 417-423.URL
6 
Hur, M. W., Lee, Y. H., and Lee, S. H. (2019), The Optimal Isolation Period of Vertically Story-added Remodeling Apartment Building with Seismic Isolation System, Journal of the Korea Institute for Structural Maintenance and Inspection, 23(3), 65-74.DOI
7 
Hur, M. W., Yoon, J. H., and Park, T. W. (2017), Seismic Performance Evaluation of Non-seismic designed Low-rise Building Retrofitted by Isolation device, Conference Journal of Korea Concrete Institute, pp. 323-324.URL
8 
Hwang, K. T. (2018), Technical Trends of RC Buildings Applied with Seismic Isolation Systems, Magazine of the Korea Concrete Institute, 30(3), 44-52.URL
9 
ISO 2631-1 (1997), : Mechanical vibration and shock – Evaluation of human exposure to whole-body vibration. Part 1: General requirements.URL
10 
ISO 2631-2 (2003), Mechanical vibration and shock – Evaluation of human exposure to whole-body vibration. Part 2: Vibration in buildings (1 Hz to 80 Hz).URL
11 
Mun, J. H., Im, C. R., Wang, H. R., and Yang, K. H. (2021), Load- Displacement Relationship of Passive Vibration Units Composed with a Spring and Vibration-Proof Rubbers, Journal of the Korea Institute for Structural Maintenance and Inspection, 25(6), 226-234.DOI
12 
Junji, S., Ryoichiro, M., Shinsuke, O., Yasuo, O., Kazuhiko, I., and Kenji, T. (2005), Research on 3-D Base Isolation System Applied to New Power Reactor 3-D Seismic Isolation Device with Rolling Seal Type Air Spring: Part 2, IASMiRT.URL
13 
Khiavi, M. P., Ghorbani, M. A., and Rahmat, A. G. (2020), Seismic Optimization of Concrete Gravity Dams Using a Rubber Damper, International Journal of Acoustics and Vibration, 25(3), 425-435.URL
14 
Kim, H. S., Kim, S. G., and Kang, J. W. (2018), Seismic Response Evaluation of Mid-Story Isolation System According to the Change of Characteristics of the Seismic Isolation Device, Journal of Korean Association for Spatial Structures, 18(1), 109-116.DOI
15 
Kim, J. S., Jo, M. J., and Kim, S. H. (2016), A Study on Evaluation of Floor Vibration for steel Frame Modular Housing, Journal of the Korea Institute for Structural Maintenamnce and Inspection, 20(1), 104-111.DOI
16 
Kim, K. Y., Lee, Y. R., Kim, H. S., and Kang, J. W. (2017), Evaluation of High-Rise Buildings Considering Installation Story of the Mid-Story Isolation System, Journal of Korean Association for Spatial Structures, 17(4), 85-92.DOI
17 
Riccardo, C., Naurizio, I., Massimo, M., Bruno, S., and Paolo, C. (2004), The Use of An Innovative 3D Isolation System for Seismic and Ambient Vibration to Protect The Roman Ship Excavated at Ercolano, Third European Conference on Structural Control, Vienna.URL
18 
SCI-P354 (2009), Design of Floors for Vibration:A New Approach (revised edition, February 2009).URL
19 
Seito, O., Kyotada, N., and Michiaki, S. M. (2003), Development of 3D Seismic Isolator using Metallic Bellows, Transactions SMiRT 17, Prague.URL
20 
Vibration regulation law (Law no. 64 of 1976, latest Amendment by Law no. 75 of 1995), (1995), Ministry of the Environment of Japan (in Japanese).URL
21 
Wei, L. S., and Zhou F. L. (2008), Vibration and Seismic Isolation Design for Buildings on Subway Platform, 14th World Conference on Earthquake Engineering, Beijing, China.URL
22 
Wilson, G. P. (1998), Vibration isolation design for Benaroya Hall, The Journal of the Acoustical Society of America, 103(5), 2906-2906.DOI
23 
Yun, C. J., Lee, S. U., and Jo, K. W. (2006), Analysis KTX wheel aged deterioration using Frequency Response Function. In Proceedings of the Korean Society for Noise and Vibration Engineering Conference (pp. 1453-1458). The Korean Society for Noise and Vibration Engineering.URL