1 
Kim, T. W., Chu, Y. R., Kim, S. R., Bhandari, D. (2018), Seismic Behavior of Domestic Piloti-type Buildings Damaged by 2017 Pohang Earthquake, Journal of the Earthquake Engineering Society of Korea, 22(3), 161-168. (in Korean, with English abstract)DOI
2 
Kim, J. C., Shin, S. H., Oh, S. H. (2019), Damage Investigation of Pilotis Structures and Analysis of Damage Causes by Pohang Earthquake, Journal of the Architectural Institute of Korea Structure & Construction, 35(2), 3-10. (in Korean, with English abstract)Google Search
3 
Kwon, U. J., Paik, J. H., Lee, S. H., Baek, E. R. (2025a), Evaluation of Torsional Moment Considering Translation of Center of Rigidity in Low-rise RC Pilotis Buildings with Torsional Irregularity, Journal of the Korea Institute for Structural Maintenance and Inspection, 29(5), 103-113. (in Korean, with English abstract)Google Search
4 
Ministry of Land, Infrastructure and Transport (MOLIT) (2022), KDS 41 17 00; Seismic Design Criteria for Buildings, Korea: National Standard Center (in Korean)Google Search
5 
Paulay, T. (1998), Torsional Mechanisms in Ductile Building Systems, Earthquake Engineering and Structural Dynamics, 27, 1101-1121.DOI
6 
Ha, T. H., Hong, S. G. (2005), Displacement-based Seismic Assessment and Rehabilitation of Asymmetric Wall Structures, Journal of the Earthquake Engineering Society of Korea, 9(3), 23-32. (in Korean, with English abstract)DOI
7 
De Stefano, M., Pintucchi, B. (2008), A Review of Research on Seismic Behaviour of Irregular Building Structures since 2002, Bulletin of Earthquake Engineering, 6, 285-308.DOI
8 
Stathopoulos, K. G., Anagnostopoulos, S. A. (2010), Accidental Design Eccentricity: Is It Important for the Inelastic Response of Buildings to Strong Earthquakes?, Soil Dynamics and Earthquake Engineering, 30(8), 782-797.DOI
9 
Ministry of the Interior and Safety (MOIS) (2018), Investigation and Analysis Report on the 2017 Pohang Earthquake Damage, National Disaster Management Research Institute (in Korean)Google Search
10 
Li, K. (2009), CANNY: 3-Dimensional Nonlinear Static/Dynamic Structural Analysis Computer Program-User ManualGoogle Search
11 
Kwon, U. J., Paik, J. H., Lee, S. H., Baek, E. R. (2025b), Effects of Strength and Plan Aspect Ratios on the Inelastic Behavior of Low-rise RC Piloti Buildings with Torsional Irregularity, Journal of the Korea Institute for Structural Maintenance and Inspection, 29(5), 114-123. (in Korean, with English abstract)Google Search
12 
Jeon, H. K., Baek, E. R., Lee, S. H. (2021), Shaking Table Test on the Piloti-type RC Frames with Horizontal Irregularity, Journal of the Architectural Institute of Korea, 37(8), 177-188. (in Korean, with English abstract)Google Search