• 대한전기학회
Mobile QR Code QR CODE : The Transactions of the Korean Institute of Electrical Engineers
  • COPE
  • kcse
  • 한국과학기술단체총연합회
  • 한국학술지인용색인
  • Scopus
  • crossref
  • orcid

References

1 
Tascioglu, F. U. N. D. A., Kuzgun, S., Armagan, O. N. U. R. & Ogutler, G, “Short-term effectiveness of ultrasound therapy in knee osteoarthritis,” Journal of International Medical Research, vol. 38, no. 4, pp. 1233-1242, 2010. DOI : 10.1177/147323001003800404DOI
2 
Khanna, A., Nelmes, R. T., Gougoulias, N., Maffulli, N. & Gray, J, “The effects of LIPUS on soft-tissue healing,” a review of literature. British medical bulletin, vol. 89, no. 1, pp. 169-182, 2009. DOI : 10.1093/bmb/ldn040DOI
3 
Harrison, A. & Alt, V, “Low-intensity pulsed ultrasound (LIPUS) for stimulation of bone healing−A narrative review,” Injury, vol. 52, no. 2, pp. 91-96, 2021. DOI : 10.1016/j.injury.2021.05.002DOI
4 
Jiang, X., Savchenko, O., Li, Y., Qi, S., Yang, T., Zhang, W. & Chen, J, “A review of low-intensity pulsed ultrasound for therapeutic applications,” IEEE Transactions on Biomedical Engineering, vol. 66, no. 10, pp. 2704-2718, 2018. DOI : 10.1109/TBME.2018.2889669DOI
5 
Harrison, A., Lin, S., Pounder, N. & Mikuni-Takagaki, Y, “Mode & mechanism of low intensity pulsed ultrasound (LIPUS) in fracture repair,” Ultrasonics, vol. 70, pp. 45-52, 2016. DOI : 10.1016/j.ultras.2016.03.016DOI
6 
Shung, K. K. & Zippuro, M, “Ultrasonic transducers and arrays,” IEEE Engineering in Medicine and Biology Magazine, vol. 15, no. 6, pp. 20-30, 1996. DOI : 10.1109/51.544509DOI
7 
Huang, J., Que, P. W. & Jin, J. H, “A parametric study of beam steering for ultrasonic linear phased array transducer,” Russian journal of nondestructive testing, vol. 40, pp. 254-259, 2004. DOI : 10.1023/B:RUNT.0000043674.60035.0eDOI
8 
Tan, J. S., Frizzell, L. A., Sanghvi, N., Wu, S. J., Seip, R. & Kouzmanoff, J. T, “Ultrasound phased arrays for prostate treatment,” The Journal of the Acoustical Society of America, vol. 109, no. 6, pp. 3055-3064, 2001. DOI : 10.1121/1.1373444DOI
9 
Poguet, J., Marguet, J., Pichonnat, F. & Chupin, L, “Phased array technology: Concepts, probes and applications,” Journal of Nondestructive Testing & Ultrasonics(Germany), vol. 7, no. 5, pp. 1-6, 2002.URL
10 
Ilham, S. J., Kashani, Z. & Kiani, M, “Design and optimization of ultrasound phased arrays for large-scale ultrasound neuromodulation,” IEEE transactions on biomedical circuits and systems, vol. 15, no. 6, pp. 1454-1466, 2021. DOI : 10.1109/TBCAS.2021.3133133DOI
11 
Paul, Y., Barthez, D. V. M., Leveille, R., Peter, V. & Scrivani, D. V. M, “Side lobes and grating lobes artifacts in ultrasound imaging,” Veterinary Radiology & Ultrasound, vol. 38, no. 5, pp. 387-393, 1997. DOI : 10.1111/j.1740-8261.1997.tb02104.xDOI
12 
Ricci, V., Soylu, A. R. & Ozcakar, L, “Artifacts and artistic facts: a visual simulation for ultrasound training,” American Journal of Physical Medicine & Rehabilitation, vol. 98, no. 6, pp. 521-525, 2019. DOI : 10.1097/PHM.0000000000001134DOI
13 
Steinberg, Bernard D, “Principles of aperture and array system design: Including random and adaptive arrays,” New York, 1976.URL
14 
Delos, P., Broughton, B. & Kraft, J, “Phased array antenna patterns−part 2: grating lobes and beam squint,” Analog Dialogue, vol. 54, no. 2, pp. 1-4, 2020.DOI
15 
Hutchinson, E. B. & Hynynen, K, “Intracavitary ultrasound phased arrays for prostate thermal therapies: MRI compatibility and in vivo testing,” Medical Physics, vol. 25, no. 12, pp. 2392-2399, 1998. DOI : 10.1118/1.598450DOI
16 
Hand, J. W., Shaw, A., Sadhoo, N., Rajagopal, S., Dickinson, R. J. & Gavrilov, L. R, “A random phased array device for delivery of high intensity focused ultrasound,” Physics in Medicine & Biology, vol. 54, no. 19, 5675 (2009). DOI : 10.1088/0031-9155/54/19/002DOI
17 
Qu, X., Shen, G., Wu, N., Wu, H., Qiao, S., Wang, E., ... & Wang, H, “Suppressing grating lobes for transcranial focused ultrasound system by frequency-modulated excitation,” IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, vol. 64, no. 12, pp. 341-351, 2020. DOI : 10.1109/TUFFC.2020.3047664DOI
18 
Oelze, M. L, “Bandwidth and resolution enhancement through pulse compression,” IEEE transactions on ultrasonics, ferroelectrics, and frequency control, vol. 54, no. 4, pp. 768-781, 2007. DOI : 10.1109/TUFFC.2007.310DOI
19 
Ponnle, A., Hasegawa, H. & Kanai, H, “Suppression of grating lobe artifacts in ultrasound images formed from diverging transmitting beams by modulation of receiving beams,” Ultrasound in medicine & biology, vol. 39, no. 4, pp. 681-691, 2013. DOI : 10.1016/j.ultrasmedbio.2012.10.019DOI
20 
Misaridis, T. & Jensen, J. A, “Use of modulated excitation signals in medical ultrasound. Part I: Basic concepts and expected benefits,” IEEE transactions on ultrasonics, ferroelectrics, and frequency control, vol. 52, no. 2, pp. 177-191, 2005. DOI : 10.1109/TUFFC.2005.1406545DOI
21 
Jensen, J. A, “Field: A program for simulating ultrasound systems,” Medical & Biological Engineering & Computing, vol. 34, no. 1, pp. 351-353, 1997.URL
22 
Jensen, J. A. & Svendsen, N. B, “Calculation of pressure fields from arbitrarily shaped, apodized, and excited ultrasound transducers,” IEEE transactions on ultrasonics, ferroelectrics, and frequency control, vol. 39, no. 2, pp. 262-267, 1992. DOI : 10.1109/58.139123DOI