• 대한전기학회
Mobile QR Code QR CODE : The Transactions of the Korean Institute of Electrical Engineers
  • COPE
  • kcse
  • 한국과학기술단체총연합회
  • 한국학술지인용색인
  • Scopus
  • crossref
  • orcid

References

1 
Yong-Dae Son, Jong-Beom Lee, “Proper Cable Arrangement Selection by Induced Voltage Evaluation of DC Cable in AC/DC Hybrid Combined Transmission Systems,” The Transactions of the Korean Institute of Electrical Engineers, vol. 64, no. 5, pp. 680-688, 2015.DOI:10.5370/KIEE.2015.64.5.680DOI
2 
Ting Zhu, Shuhong Wang, Naming Zhang, Youxiang Yan, Ze Guo, Shuoyu Wang, Shuang Wang, “Study on the Electromagnetic Field in HVDC/AC Hybrid Submarine Cable Tunnel,” 2018 IEEE International Conference on High Voltage Engineering and Application (ICHEVE), 2018.DOI:10.1109/ICHVE.2018.8641849DOI
3 
Paul S. van der Merwe, Howard C. Reader, Daniël J Rossouw, “Cable Tray Connections for Electromagnetic Interference (EMI) Mitigation,” IEEE Transactions on Electromagnetic Compatibility, vol. 53, no. 2, pp. 332-338, 2011.DOI:10.1109/TEMC.2010.2079937DOI
4 
Xiaoyu JIA, Changsheng HU, Bitao DONG, Fengchun HE, Hui WANG, Dehong Xu, “Influence of System Layout on CM EMI Noise of SiC Electric Vehicle Powertrains,” CPSS Transactions on Power Electronics and Applications, vol. 6, no. 4, pp. 298-308, 2021.DOI:10.1109/IEEESTD.2014.6905681DOI
5 
Juntao Yao, Shuo Wang, Zheng Luo, “Modeling and Reduction of Radiated EMI in Non-isolated Power Converters in Automotive Applications,” 2020 IEEE Applied Power Electronics Conference and Exposition (APEC), 2020.DOI:10.1109/APEC39645.2020.9124443DOI
6 
Robert Uhl, Antonello Monti, Julian Lichitinghagen, Albert Moser, “Analysis of transient electromagnetic interference between medium voltage AC and DC overhead transmission lines and cables,” 2016 IEEE International Energy Conference (ENERGYCON), Apr. 2016.DOI:10.1109/ENERGYCON.2016.7514025DOI
7 
Jian Zhong Xu, Sicheng Zhu, Chengyu Lil, Chengyong Zhao, “DC fault current calculation method in MMC-HVDC grid considering current-limiting devices,” The Journal of Engineering, vol. 2019, no. 16, pp. 3188-3195, Dec. 2018.DOI:10.1049/joe.2018.8766DOI
8 
Bin Jiang, Yanfeng Gong, “Arm Overcurrent Analysis and Calculation of MMC-HVDC System with DC-link Pole-to-Pole Fault,” Electric Power Components and Systems, vol. 46, no. 2, pp. 177-186, Apr. 2018.DOI:10.1080/15325008.2018.1432725DOI
9 
IEEE Guide for Bonding Shields and Sheaths of Single-Conductor Power Cables Rated 5kV through 500kV, ANSI/IEEE Std 575-2014, 2014.DOI:10.1109/IEEESTD.2014.6905681DOI
10 
Bahadir AKBAL, “High Voltage underground cable bonding optimisation to prevent cable termination faults in mixed high-voltage lines,” IET Generation, Transmission & Distribution, vol. 14, no. 20, pp. 4331-4338, 2020.DOI:10.1049/iet-gtd.2019.1559DOI
11 
Wu, Yifei, et al., “A novel current injection DC circuit breaker integrating current commutation and energy dissipation,” IEEE Journal of Emerging and Selected Topics in Power Electronics, vol. 8, no. 3, pp. 2861-2869, 2019.DOI:10.1109/JESTPE.2019.2911103DOI
12 
S. M Lee, Y. H Lee, “The Study on the Amp.km Calculation Method in the Estimation of Induced Voltage by Super-speed Express Railway on Telecommunication Line,” Electronics and Telecommunications Trends, vol. 18, no. 81, pp. 75-82, 2003.DOI:10.22648/ETRI.2003.J.180309DOI
13 
Hyun-Soo Kim, et al., “A Fault Effect to Induced Voltage of Gas Pipeline in Transmission Systems,” The Transactions of the Korean Institute of Electrical Engineers, vol. 57, no. 10, pp. 1720-1725, 2008.URL