Mobile QR Code QR CODE : The Transactions P of the Korean Institute of Electrical Engineers
The Transactions P of the Korean Institute of Electrical Engineers

Korean Journal of Air-Conditioning and Refrigeration Engineering

ISO Journal TitleTrans. P of KIEE
  • Indexed by
    Korea Citation Index(KCI)

References

1 
Park C. W., Lee K. M., et al. , 2018, Ground Fault Analysis of Ungrounded DC Microgrid, KIEE Summer conference, pp. 482-483Google Search
2 
Cho J. T., 2018, Development and implementation of DC distribution, KIIEE Spring conference, LVDC workshop, pp. 133-148Google Search
3 
An T. P., et al. , 2016, Development of high-speed circuit breakers for low-voltage DC distribution system, KEPRI Service proposal, pp. 1-160Google Search
4 
KapJin , 2016, DC Distribution Technology Overview and Development Examples, pp. 1-59Google Search
5 
Ko Y. S., 2016, Examples of power conversion system design and technology development suitable for DC distribution, KapJin, pp. 1-48Google Search
6 
Shin S. S., 2018, Establishment and revision of LVDC distribution facility standards, KIIEE Spring conference, LVDC workshop, Vol. 권, No. 호, pp. 167-176Google Search
7 
Chang S. Y., 2018, LVDC distribution technology trend, KIIEE Spring conference, LVDC workshop, pp. 151-164Google Search
8 
Hyosung , 2016, Construction of DC Grid System with Distributed Energy Resources in an island, Service plan, pp. 1-90Google Search
9 
Park S. J., Park S. M., Lee J. H., 2015, DC power distribution and DC breaker technology trend, The Korean Institute of Electrical Engineers, Vol. 67, No. 7, pp. 27-33Google Search
10 
Kim H. S., Han S. Y., Han H. S., 2014, Development of DC Leakage Current Sensor for Solar Power Generation System, Trans. KIEE, Vol. 63, No. 6, pp. 828-833DOI
11 
IEC 60364-1ed5.0 , 2005, Low voltage electrical installationsGoogle Search
12 
Kim Hongjoo, Cho Youngpyo, Kim Jaehan, Cho Jintae, Kim Juyong, 2017, Demonstration of the LVDC distribution system in an island, 24th International Conference & Exhibition on Electricity Distribution (CIRED), IET Journals, pp. 2215-2218DOI
13 
Bender , 2016, ISOMETER iso1685, Manual, pp. 1-39Google Search
14 
Oliver Schaefer, Karl Schepp, 2015, Method and Device for Monitoring the insulation of ungrounded DC and AC voltage networks, Bender, United States Patent, US9,069,025 B2, pp. 1-19Google Search
15 
ABB , Data sheet, pp. 1-20Google Search
16 
Lee W. S., 2012, Selective Ground Fault Protection Algorithm For DC Traction Systems, Myongji University, Master's thesis, pp. 1-27Google Search
17 
Kim S. H., 2017, A Study of Leakage Detection Technology for available DC Distribution, Seoul National University of Science and Technology, Master's thesis, pp. 1-48Google Search
18 
Park Jae-Do, 2015, Ground Fault Detection and Location for Ungrounded DC Traction Power Systems, IEEE Trans. Vechcular Technology, Vol. 64, No. 12, pp. 5667-5676DOI
19 
Guan Shaopeng, Nai Changxin, Sun Wenyan, Dong Lu, 2009, Direct Current Circuit model for landfill leakage detection, The Ninth International Conference on Electronic Measurement & Instruments (ICEMI 2009), pp. 2-693-2-696DOI
20 
Yang Ruijing, 2016, The Study of Locating Ground Faults in DC Microgrid Using Wavelet Transform, University of Wisconsin-Milwaukee Master thesis, pp. 1-75Google Search
21 
Olszowiec Piotr, 2014, Insulation Measurement and Supervision in Live AC and DC Unearthed Systems, Second Edition, Springer, pp. 1-180DOI
22 
Karmacharya Indra Man, Gokaraju Ramakrishna, 2018, Fault Location in Ungrounded Photovoltaic System Using Wavelets and ANN, IEEE Trans. Power Delivery, Vol. 33, No. 2, pp. 549-559DOI