Mobile QR Code QR CODE : Korean Journal of Air-Conditioning and Refrigeration Engineering
Korean Journal of Air-Conditioning and Refrigeration Engineering

Korean Journal of Air-Conditioning and Refrigeration Engineering

ISO Journal TitleKorean J. Air-Cond. Refrig. Eng.
  • Open Access, Monthly
Open Access Monthly
  • ISSN : 1229-6422 (Print)
  • ISSN : 2465-7611 (Online)
Title Performance Analysis of Gas Injection in an Electric Scroll Compressor of Mobile Heat Pump System
Authors Jeong Taek Lim ; Jae Woong Choi ; Hyun Jin Kim
DOI https://doi.org/10.6110/KJACR.2019.31.7.289
Page pp.289-301
ISSN 1229-6422
Keywords 스크롤 압축기 ; 가스 인젝션 ; 히트펌프 Scroll compressor ; Gas injection ; Heat pump
Abstract For an electric scroll compressor of mobile heat pump system, numerical analysis have been carried out for performance enhancement by gas injection. Optimum injection pressure is determined by balancing between vapor production rate in a flash tank downstream of the first expansion valve and vapor reception rate in a compression chamber of the scroll. For standard heating condition of Te = -10.07℃ and Tc = 62.89℃, heating capacity and COP increase by 31.2% and 8.93%, respectively through vapor injection. Performance enhancement by vapor injection becomes greater with lower evaporating temperature and higher condensing temperature. For chamber type injection structure where injection passage length from injection chamber to compression chamber is reduced, further performance increase can be obtained by vapor injection : 1~7%P more in the capacity and 0.4~6.6%P more in COP.