Mobile QR Code QR CODE : Korean Journal of Air-Conditioning and Refrigeration Engineering

  1. μ—°μ„ΈλŒ€ν•™κ΅ 건좕곡학과 석박사 톡합과정 ( M.D. Integration, Department of Architectural Engineering, Yonsei University, 50 Yonsei-ro Seodaemun-gu, Seoul, 03722, Korea )
  2. μ„ΈλŒ€ν•™κ΅ 건좕곡학과 박사과정 ( Ph.D. Candidate, Department of Architectural Engineering, Yonsei University, 50 Yonsei-ro Seodaemun-gu, Seoul, 03722, Korea )
  3. μ—°μ„ΈλŒ€ν•™κ΅ 건좕곡학과 석사과정 ( M.S Student, Department of Architectural Engineering, Yonsei University, 50 Yonsei-ro Seodaemun-gu, Seoul, 03722, Korea )
  4. μ—°μ„ΈλŒ€ν•™κ΅ 건좕곡학과 ꡐ수 ( Professor, Department of Architectural Engineering, Yonsei University, 50 Yonsei-ro Seodaemun-gu, Seoul, 03722, Korea )



Prediction of heating energy usage(λ‚œλ°© μ—λ„ˆμ§€ μˆ˜μš”λŸ‰ 예츑), CHP(열병합 λ°œμ „), Energy saving(μ—λ„ˆμ§€ μ ˆμ•½), Apartment houses(곡동주택), Machine learning(기계 ν•™μŠ΅)

κΈ°ν˜Έμ„€λͺ…

$S$ οΌšμΈκ³΅μ‹ κ²½λ§μ„ ν™œμš©ν•œ μ—λ„ˆμ§€ μˆ˜μš”λŸ‰ 예츑 κ°’

$M$ οΌšμΈ‘μ •λœ μ—λ„ˆμ§€ μˆ˜μš”λŸ‰

$A$ οΌšμΈ‘μ •λœ κΈ°κ°„μ˜ 평균 μ—λ„ˆμ§€ μˆ˜μš”λŸ‰

1. 연ꡬ배경 및 λͺ©μ 

1.1 연ꡬ배경

μ„Έκ³„μ μœΌλ‘œ μ˜¨μ‹€κ°€μŠ€ λ°°μΆœλŸ‰μ΄ μ¦κ°€ν•˜λ©° 세계 곳곳에 이상기후 ν˜„μƒμ΄ λ°œμƒν•˜κ³  μžˆλ‹€. 이에 따라 λŒ€κΈ° 쀑 μ˜¨μ‹€κ°€μŠ€ μ•ˆμ •ν™”λ₯Ό μœ„ν•΄ 2015λ…„ 12μ›” ν”„λž‘μŠ€ νŒŒλ¦¬μ—μ„œ 제 21μ°¨ μœ μ—”κΈ°ν›„λ³€ν™”ν˜‘μ•½(United Nations Framework Convention on Climate Change : UNFCCC) 당사ꡭ μ΄νšŒμ—μ„œ μ΅œμ’… ν•©μ˜λ¬ΈμΈ νŒŒλ¦¬ν˜‘μ •μ„ λ°œνš¨ν•˜μ˜€λ‹€. νŒŒλ¦¬ν˜‘μ •μ— μ•žμ„œ μ œμΆœν•œ 각ꡭ의 μ˜¨μ‹€κ°€μŠ€ 저감λͺ©ν‘œ(INDC)μ—μ„œ μš°λ¦¬λ‚˜λΌλŠ” 2030λ…„ κ΅­κ°€ μ˜¨μ‹€κ°€μŠ€ λ°°μΆœμ „λ§μΉ˜(Business As Usual : BAU) λŒ€λΉ„ 37% 저감을 λͺ©ν‘œλ‘œ ꡭ제 μ‚¬νšŒμ— κ³΅ν‘œν•˜μ˜€λ‹€.(1) ν•˜μ§€λ§Œ 2018 μ—λ„ˆμ§€ κ²½μ œμ—°κ΅¬μ›μ˜ 연ꡬ 결과에 λ”°λ₯΄λ©΄ μš°λ¦¬λ‚˜λΌμ˜ μ΅œμ’…μ—λ„ˆμ§€ μ†ŒλΉ„λŸ‰μ€ κ³„μ†ν•΄μ„œ 맀년 μ¦κ°€ν•˜κ³  있으며 90% 이상을 ν•΄μ™Έ μ—λ„ˆμ§€ μˆ˜μž…μ— μ˜μ‘΄ν•˜κ³  μžˆλŠ” 싀정이닀. λ”°λΌμ„œ, μ˜¨μ‹€κ°€μŠ€ 배좜 μ €κ°λΏλ§Œ μ•„λ‹ˆλΌ κ΅­κ°€ μ—λ„ˆμ§€ μ•ˆλ³΄λ₯Ό μœ„ν•œ μ—λ„ˆμ§€ 절감 μ‹œμŠ€ν…œ ꡬ좕이 ν•„μš”ν•˜λ‹€.

μ΄λŸ¬ν•œ λ¬Έμ œμ μ— λŒ€ν•œ λŒ€μ‘μ˜ μΌν™˜μœΌλ‘œ, λΆ„μ‚°ν˜• 전원 쀑 ν•˜λ‚˜μ΄λ©° μ—λ„ˆμ§€ μ ˆμ•½μ— νš¨κ³Όκ°€ μžˆλŠ” μ—΄λ³‘ν•©λ°œμ „ μ‹œμŠ€ν…œμ΄ μ œμ‹œλ˜κ³  μžˆλ‹€. μ—΄λ³‘ν•©λ°œμ „μ΄λž€ CHP(Combined Heat and Power Generation) 및 Cogeneration으둜 뢈리우고, ν•˜λ‚˜μ˜ μ—°λ£Œλ₯Ό μ‚¬μš©ν•˜μ—¬ μ—΄κ³Ό μ „κΈ°λ₯Ό λ™μ‹œμ— μƒμ‚°ν•˜λŠ” μ’…ν•© μ—λ„ˆμ§€ μ‹œμŠ€ν…œμ„ λ§ν•œλ‹€.(2) μ „κΈ°λ₯Ό μƒμ‚°ν•˜λŠ” κ³Όμ • μ—μ„œ 남은 열은 보일러, ν‘μˆ˜μ‹ 냉동기 등에 μ΄μš©ν•˜μ—¬ μ΄μ‚°ν™”νƒ„μ†Œ μ–΅μ œ 및 ν™˜κ²½ 곡해 λ¬Έμ œμ— κΈ°μ—¬ν•  수 μžˆλ‹€.(3) μ—΄λ³‘ν•©λ°œμ „μ‹œμŠ€ν…œμ˜ λ°œμ „νš¨μœ¨μ€ μ’…λ₯˜μ— 따라 λ‹€λ₯΄λ©° μ•½ 25~40% λ²”μœ„λ₯Ό μœ μ§€ν•˜κ³ , 배열은 λ°œμ „λŸ‰μ˜ 1.5~2λ°° 정도 λ°œμƒν•œλ‹€. μ•½ 65~85% νš¨μœ¨μ„ 가지고 있으며 기쑴에 μžˆλŠ” ν™”λ ₯λ°œμ „μ†Œλ³΄λ‹€ 높은 μ—λ„ˆμ§€ 효율 ν˜•νƒœλ₯Ό 띄고 μžˆλ‹€.(4)

μ—΄λ³‘ν•©λ°œμ „ μ‹œμŠ€ν…œ 운영 μ‹œ μš°λ¦¬λ‚˜λΌλŠ” μ‚¬κ³„μ ˆμ΄ λšœλ ·ν•œ λ‚˜λΌμ— μ†ν•˜κΈ°μ— κ³„μ ˆλ³„ μ—΄ μ—λ„ˆμ§€ μˆ˜μš”μ˜ νŠΉμ§•μ„ κ³ λ €ν•΄μ•Ό ν•œλ‹€. μ•„νŒŒνŠΈλ‚˜ μ˜€ν”ΌμŠ€ λΉŒλ”©μ€ ν•˜μ ˆκΈ°μ—” λƒ‰λ°©μœΌλ‘œ μΈν•œ μ „κΈ°, λ™μ ˆκΈ°μ—” 급탕을 μœ„ν•œ κ°€μŠ€λ₯Ό μ£Όμš” μ—λ„ˆμ§€μ›μœΌλ‘œ μ‚¬μš©ν•œλ‹€. 즉, ν•˜λ‚˜μ˜ κ±΄λ¬Όμ—μ„œ 1λ…„ λ™μ•ˆ κ³„μ ˆμ— 따라 λ‹€λ₯Έ λ°©μ‹μ˜ λƒ‰β‹…λ‚œλ°© μ—λ„ˆμ§€μ›μ„ μ‚¬μš© ν•˜κ²Œ λœλ‹€. 특히, λ™μ ˆκΈ°μ—” 급탕 μˆ˜μš”λŸ‰μ΄ μ¦κ°€ν•˜κ³  여름철엔 급탕 μˆ˜μš”λŸ‰μ΄ μ€„μ–΄λ“€κ²Œ λ˜μ–΄ ν•˜μ ˆκΈ° 냉방을 μœ„ν•œ μ „κΈ° μ‚¬μš©λŸ‰μ— 맞좰 열병합 λ°œμ „μ‹œμŠ€ν…œμ„ μš΄μ˜ν•  경우 λ°œμƒλœ 폐열 μ²˜λ¦¬κ°€ μ–΄λ €μ›Œμ§„λ‹€. λ”°λΌμ„œ ν˜„μž¬ μ—΄ κ³΅κΈ‰μžλ“€μ€ 폐열 처리 및 μš΄μ „λΉ„μš© μ†μ‹€μ˜ μ΅œμ†Œν™”λ₯Ό μœ„ν•΄ λ™μ ˆκΈ°μ—” 열좔쒅방식을 μ΄μš©ν•˜λ©°, ν•˜μ ˆκΈ°μ—” μ „κΈ° 좔쒅방식을 μ΄μš©ν•˜κ±°λ‚˜ μš΄μ „μ„ μ•„μ˜ˆ μ •μ§€ν•˜λŠ” 두 가지 λ°©ν–₯으둜 μš΄μ˜ν•˜λŠ” 싀정이닀.(5)

이에 따라, μ—΄λ³‘ν•©λ°œμ „ μ‹œμŠ€ν…œμ˜ μ—΄ κ³΅κΈ‰μžλ“€μ€ κ³„μ ˆ λ“± μ—¬λŸ¬ μš”μΈμ„ κ³ λ €ν•΄ μ „λ ₯κ±°λž˜μ†Œμ— μ—΄κ³Ό μ „κΈ° μ—λ„ˆμ§€ 곡급 μŠ€μΌ€μ€„μ„ 미리 λ“±λ‘ν•œλ‹€. 예츑이 λΆ€μ •ν™•ν•  경우 운영 κ³„νšμ΄ λ³€κ²½λ˜μ–΄μ§€λ©°, 기쑴수읡이 λ³€κ²½λ˜μ–΄ κ°μ†Œλ˜κ³  μΆ”κ°€μ μœΌλ‘œ λ°œμƒν•˜λŠ” 기동 μ •μ§€λ‘œ 인해 μ‹œμŠ€ν…œ μš΄μ „λΉ„μš© 손싀이 λ°œμƒν•˜κ²Œ λœλ‹€. 이 λ•Œλ¬Έμ— μ—΄ κ΄€λ¦¬μžλŠ” μ£Όλ³€μ˜ λŒ€κ·œλͺ¨ 건물의 μ—΄ μˆ˜μš”λŸ‰μ„ ν•˜λ£¨ λ‹¨μœ„λ‘œ μ •ν™•νžˆ μ˜ˆμΈ‘ν•΄μ•Ό ν•˜λ©°, μš΄μ˜λΉ„μš©μ„ 미리 μ‚°μ •ν•˜μ—¬ ν™˜κ²½μ , 경제적으둜 합리적인 운영 κ³„νšμ„ 사전에 μˆ˜λ¦½ν•΄μ•Ό ν•œλ‹€.(6)

1.2 λ¬Έν—Œκ³ μ°°

이에 따라, μ •ν™•ν•œ μ—΄ μˆ˜μš” μ˜ˆμΈ‘μ„ μœ„ν•΄ λ§Žμ€ 연ꡬ가 진행 쀑에 μžˆλŠ”λ°, μ„ ν–‰ μ—°κ΅¬μ—μ„œ 솑기범(7)은 닀쀑 νšŒκ·€λΆ„μ„μ„ 톡해 μ™ΈκΈ° μ˜¨λ„, 예츑 7일 μ „κΉŒμ§€μ˜ μ—΄λŸ‰, 월별, 주별(κΈˆμš”μΌ, ν† μš”μΌ, μΌμš”μΌ) λ³€μˆ˜λ‘œ μ—΄ μˆ˜μš”λ₯Ό μ˜ˆμΈ‘ν•˜μ˜€λ‹€. 이재승(8)은 μ™ΈκΈ° AR을 톡해 μ™ΈκΈ° μ˜¨λ„, μ—΄λŸ‰μœΌλ‘œ μ—΄ μˆ˜μš” 예츑λͺ¨λΈμ„ κ°œλ°œν•˜μ˜€κ³ , κΉ€λ―Όμ˜(9)의 경우 ANN을 톡해 μ—΄ μˆ˜μš” μ˜ˆμΈ‘μ„ μ§„ν–‰ν•˜μ˜€λ‹€. κΉ€ν–₯λ―Ό(10)의 경우 AR을 ν™œμš©ν•΄ μ™ΈκΈ° μ˜¨λ„, κ°•μˆ˜λŸ‰, 풍속, μ „λ‚  μ—΄λŸ‰κ³Ό 절기λ₯Ό κ΅¬λΆ„ν•˜μ—¬ μ—΄λ³‘ν•©λ°œμ „μ„ μœ„ν•œ μ—΄ μˆ˜μš” 예츑 λͺ¨λΈμ„ κ°œλ°œν•˜μ˜€μœΌλ©°, λ°±μ’…κ΄€(11)은 μ„ ν˜•νšŒκ·€λͺ¨ν˜•μ„ μ΄μš©ν•˜μ—¬ μ™ΈκΈ° μ˜¨λ„, μ²΄κ°μ˜¨λ„, 풍속, μ—΄λŸ‰μ„ μ΄μš©ν•˜μ—¬ 겨울철 μ—΄ μˆ˜μš” μ˜ˆμΈ‘μ„ μœ„ν•œ μ„ ν˜•νšŒκ·€λͺ¨ν˜•μ„ κ°œλ°œν•˜μ˜€λ‹€. μ„œλ³‘μ„ (12)은 μƒνƒœκ΅¬λΆ„λͺ¨ν˜•μ„ μ΄μš©ν•΄ μ™ΈκΈ° μ˜¨λ„, μ—΄λŸ‰, 월별, 주별, 일별을 μ ˆκΈ°λ§ˆλ‹€ κ΅¬λΆ„ν•˜μ—¬ μ§€μ—­λ‚œλ°© μ—΄μ—λ„ˆμ§€ μˆ˜μš”λ₯Ό μ˜ˆμΈ‘ν•˜μ˜€λ‹€.

1.3 연ꡬλͺ©μ 

μ„ ν–‰ μ—°κ΅¬μ—μ„œλ„ μ•Œ 수 μžˆλ“―μ΄, κΈ°μ‘΄ λ¬Έν—Œλ“€μ€ λŒ€λΆ€λΆ„ μ™ΈκΈ° μ˜¨λ„λ₯Ό κ³ λ €ν•˜μ—¬ μΈ‘μ •ν•˜μ˜€λ‹€. μ™ΈκΈ° μ˜¨λ„λŠ” κ³Όκ±° μΈ‘μ • 데이터λ₯Ό 기반으둜 ν•œ μ˜¨λ„ μˆ˜μ •κ³„μˆ˜μ™€ κΈ°μƒμ˜ˆλ³΄λ₯Ό μ‚¬μš©ν•˜μ—¬ μ™ΈκΈ° μ˜¨λ„λ₯Ό μ˜ˆμΈ‘ν•˜λŠ” λͺ¨λΈμ„ 주둜 μ‚¬μš© ν•˜λŠ”λ°,(14) μ΄λŠ” μ‹€μ‹œκ°„μœΌλ‘œ μΈ‘μ •ν•˜λŠ” μ™ΈκΈ° μ˜¨λ„ 정보λ₯Ό μ΄μš©ν•˜μ—¬ μ˜€μ°¨μ™€ μ˜¨λ„λ₯Ό λ³΄μ •ν•˜κΈ° λ•Œλ¬Έμ— μ‹€μ‹œκ°„ 졜적 μš΄μ „μ— 강점을 가진닀. ν•˜μ§€λ§Œ ν•˜λ£¨ 전에 μ‹œμŠ€ν…œμ˜ μš΄μ „ κ³„νšμ„ μ„Έμš°κΈ°μ—λŠ” 어렀움이 λ”°λ₯Έλ‹€.(13) λ˜ν•œ 기상 데이터λ₯Ό κ³ λ €ν•œ μ™ΈκΈ° μ˜¨λ„ μ˜ˆμΈ‘μ€ ν˜„μž¬ 기상 μ˜ˆλ³΄κ°€ μ œκ³΅ν•˜μ§€ λͺ»ν•˜λŠ” μ²­λͺ…κ³„μˆ˜ λ“± μž…λ ₯ 값을 ν¬ν•¨ν•˜κ³  μžˆμ–΄ 기상 예츑 λͺ¨λΈμ— μ μš©ν•˜κΈ° μ–΄λ ΅λ‹€.(14) λ”°λΌμ„œ ν˜„μž₯μ—μ„œ μ—΄ μ—λ„ˆμ§€ μˆ˜μš”λŸ‰ μ˜ˆμΈ‘μ„ μœ„ν•΄ 츑정이 κ°„λ‹¨ν•˜λ©΄μ„œλ„ μ‹ λ’°ν•  수 μžˆλŠ” κ²°κ³Όλ₯Ό 얻을 수 μžˆλŠ” 예츑 방법이 ν•„μš”ν•˜λ‹€.

κΈ°μ‘΄ 각 μ„ΈλŒ€λ‘œ μ—΄ μ—λ„ˆμ§€λ₯Ό κ³΅κΈ‰ν•˜λŠ” λŒ€μƒ μ—΄λ³‘ν•©λ°œμ „ μ‹œμŠ€ν…œμ˜ μš΄μ˜λ°©μ‹μ€ μ™ΈκΈ° μ˜¨λ„μ— λ”°λ₯Έ ν”„λ‘œκ·Έλž¨μ„ μ΄μš©ν•˜μ—¬ μš΄μ „ν•˜λŠ” 방식을 μ‚¬μš©ν•˜κ³  μžˆλ‹€. μ™ΈκΈ° μ˜¨λ„μ— 따라 λ³€μœ λŸ‰, λ³€μ˜¨λ„ 곡급방식을 μ΄μš©ν•˜λ©°, 각 μ™ΈκΈ° μ˜¨λ„ -10℃, -5℃, 0℃, 5℃, 10℃에 따라 κ³΅κΈ‰μ˜¨λ„λ₯Ό 60℃, 56℃, 53℃, 49℃, 45℃도 λ“±μœΌλ‘œ μ„€μ •ν•˜μ—¬ μ™ΈκΈ°μ˜¨λ„λ³„ 적정 μ˜¨λ„λ‘œ 단지별 싀정에 맞게 μ‹€μ‹œκ°„μœΌλ‘œ μ‘°μ •ν•˜λŠ” 방식을 μ±„νƒν•˜κ³  μžˆλ‹€.(15) μ΄λŸ¬ν•œ 방식은 μˆ˜μš”λŸ‰κ³Ό κ³΅κΈ‰λŸ‰μ— 차이가 λ°œμƒν•  수 있으며, ν•˜λ£¨ μ „ μš΄μ „ κ³„νšμ„ μ„Έμš°κΈ°μ— 어렀움이 λ”°λ₯Έλ‹€. λ§Œμ•½ μ—λ„ˆμ§€ κ³΅κΈ‰λŸ‰κ³Ό μˆ˜μš”λŸ‰μ— 차이가 λ°œμƒν•œλ‹€λ©΄ μˆœν™˜ νŽŒν”„μ˜ 동λ ₯λΉ„κ°€ μ¦κ°€ν•˜μ—¬ κ³΅λ™λ‚œλ°©λΉ„κ°€ μ¦κ°€ν•˜κ³  μ‚¬μš©μžμ˜ λ§Œμ‘±λ„ ν’ˆμ§ˆμ΄ μ €ν•˜λ˜λŠ” λ“± μ—¬λŸ¬ κ²°κ³Όλ₯Ό μ΄ˆλž˜ν•œλ‹€.

μœ„μ— μ–ΈκΈ‰ν–ˆλ“―μ΄, 건물의 μ—΄ μˆ˜μš”λŸ‰μ„ ν•˜λ£¨ λ‹¨μœ„λ‘œ 미리 μ˜ˆμΈ‘ν•˜μ—¬ 운영 방식을 μ •ν™•νžˆ μ‚°μ •ν•΄ μˆ˜μš”λŸ‰κ³Ό κ³΅κΈ‰λŸ‰μ˜ 차이λ₯Ό μ΅œμ†Œν™” ν•œλ‹€λ©΄, ν™˜κ²½μ , 경제적으둜 합리적인 κ²°κ³Όλ₯Ό λ„μΆœν•  수 μžˆλ‹€. λ˜ν•œ, μ‚¬μš©μžμ˜ λ§Œμ‘±λ„λ₯Ό 높이고, μ—΄ κ΄€λ¦¬μžμ—κ²Œ μ›ν™œν•œ μ˜μ‚¬κ²°μ • νŒλ‹¨μ— 도움을 쀄 수 μžˆλ‹€. λ”°λΌμ„œ, μ‚¬μš©μžμ˜ μŠ€μΌ€μ€„κ³Ό ν•„μš” 여건에 λ§žλŠ” 졜적의 μš΄μ „ λͺ¨λ“œλ₯Ό μ°Ύμ•„ 효율적인 μš΄μ „μ„ ν•΄μ•Όν•œλ‹€.

λ˜ν•œ κ΅­λ‚΄μ—μ„œ 기계 ν•™μŠ΅μ— λŒ€ν•œ 관심이 λ§Žμ•„μ§€κ³  μžˆμœΌλ‚˜ 이λ₯Ό ν™œμš©ν•΄ μ—΄ μˆ˜μš”λŸ‰ 예츑 μ—°κ΅¬λŠ” 맀우 적은 싀정이닀. 특히 μ—΄λ³‘ν•©λ°œμ „ μ‹œμŠ€ν…œμ„ μœ„ν•œ μ—΄ μ—λ„ˆμ§€ μ‚¬μš©λŸ‰ 예츑 ν™œμš©μ—λŠ” 연ꡬ가 λ―ΈλΉ„ν•˜λ‹€. λ”°λΌμ„œ, λ³Έ μ—°κ΅¬λŠ” 열병합 λ°œμ „μ‹œμŠ€ν…œμ„ μ΄μš©ν•˜λŠ” 곡동주택 κ±΄λ¬Όμ—μ„œ μž₯λΉ„λ₯Ό μ‚¬μš©ν•˜μ—¬ 츑정이 ν•„μš”ν•œ μ™ΈκΈ° μ˜¨λ„μ™€ μŠ΅λ„, 일ꡐ차, 평균값 데이터 등은 λͺ¨λ‘ μ œμ™Έν•˜κ³ , μ „λ‚  기둝된 일별 μ—΄, μœ λŸ‰ μ—λ„ˆμ§€ 그리고 μŠ€μΌ€μ€„ 데이터 λ“± 비ꡐ적 츑정이 κ°„λ‹¨ν•œ 데이터λ₯Ό ν™œμš©ν•˜μ˜€λ‹€. μ˜ˆμΈ‘μ„ μœ„ν•΄ 기계 ν•™μŠ΅ 쀑 ANN, SVR(Linear, RBF, Polynomial)으둜 λ‹€μŒ λ‚  μ—΄ μ—λ„ˆμ§€ μˆ˜μš”λŸ‰μ„ μ˜ˆμΈ‘ν•˜κ³ μž ν•˜λ©°, 정확도 검증을 μœ„ν•œ λ°©μ•ˆμœΌλ‘œ CvRMSE, MBEλ₯Ό ν™œμš©ν•΄ 열병합 λ°œμ „μ‹œμŠ€ν…œ 폐열 생산 μ΅œμ†Œν™”λ₯Ό 도λͺ¨ν•΄ 보고자 ν•œλ‹€.

2. 연ꡬ방법 및 λ²”μœ„

μ•žμ„œ μ–ΈκΈ‰ν–ˆλ“―μ΄ λ³Έ μ—°κ΅¬μ˜ λͺ©μ μ€ μ—΄λ³‘ν•©λ°œμ „ μ‹œμŠ€ν…œμ„ μ΄μš©ν•˜λŠ” 곡동주택 κ±΄λ¬Όμ—μ„œ μ™ΈκΈ° μ˜¨λ„ 데이터λ₯Ό μ‚¬μš©ν•˜μ§€ μ•Šκ³ , κ³Όκ±° μ‹€μΈ‘ 데이터와 μ‰½κ²Œ μΈ‘μ •ν•  수 μžˆλŠ” μŠ€μΌ€μ€„ μ •λ³΄λ§ŒμœΌλ‘œ λ‹€μŒ λ‚ μ˜ μ—΄ μ—λ„ˆμ§€ μ‚¬μš©λŸ‰μ„ μ˜ˆμΈ‘ν•˜λŠ” λͺ¨λΈμ„ μ œμ•ˆν•˜λŠ” 데 μžˆλ‹€. 이λ₯Ό μœ„ν•΄ 기계 ν•™μŠ΅ 쀑 ANNκ³Ό SVRμ•Œκ³ λ¦¬μ¦˜μ„ μ΄μš©ν•˜μ˜€κ³  λͺ¨λΈ μž…λ ₯ κ°’μœΌλ‘œ λ‚ μ§œ(Month), μ „λ‚  μ—΄ μ—λ„ˆμ§€ μ‚¬μš©λŸ‰, μ „λ‚  κΈ‰μˆ˜λŸ‰ λ“± 비ꡐ적 μ†μ‰½κ²Œ μˆ˜μ§‘μ΄ κ°€λŠ₯ν•œ λ°μ΄ν„°λ§Œμ„ μ‚¬μš©ν•΄ κ°„λ‹¨ν•˜κ³  νŽΈμ˜μ„±μ„ κ³ λ €ν•œ λͺ¨λΈλ‘œ μ§„ν–‰ν•œλ‹€.

λŒ€μƒ λ°μ΄ν„°μ˜ μ—΄ μ—λ„ˆμ§€ μ‚¬μš©λŸ‰κ³Ό κΈ‰μˆ˜λŸ‰μ€ 일별 μ‚¬μš©λŸ‰μ„ κΈ°λ‘ν•˜λŠ” 일지λ₯Ό ν†΅ν•˜μ—¬ ν™•λ³΄ν•˜μ˜€λ‹€. λŒ€μƒ 건물은 μ§€μ—­λ‚œλ°© 쀑 열병합 λ°œμ „ μ‹œμŠ€ν…œμ„ μ΄μš©ν•˜λŠ” 전라남도 λ‚˜μ£Όμ‹œμ— μœ„μΉ˜ν•œ μ—¬λŸ 개의 λ‹¨μ§€λ‘œ 이루어진 μ•„νŒŒνŠΈ 이며, 2018λ…„ 01μ›” 01일뢀터 2019λ…„ 01μ›” 29μΌκΉŒμ§€μ˜ 일별 데이터이닀. μ‚¬μš©λœ λ°μ΄ν„°λŠ” 일별 μ—΄λŸ‰, μœ λŸ‰μ΄λ©° λͺ¨λ‘ ν˜„μž₯μ—μ„œ 맀일 μΌμ •ν•œ μ‹œκ°„μ— μ‹€μΈ‘ 및 수기둜 μž‘μ„±λœ 데이터이닀.

μ—΄ μ—λ„ˆμ§€ μ‚¬μš©λŸ‰ μ˜ˆμΈ‘μ— μ ν•©ν•œ μž…λ ₯ λ³€μˆ˜λ₯Ό μ„ μ •ν•˜κΈ° μœ„ν•΄ κ±΄λ¬Όμ—μ„œ μˆ˜μ§‘ν•œ 데이터듀을 ν™•λ³΄ν•˜μ—¬ 상관 관계 뢄석을 μ‹€μ‹œν•˜μ˜€λ‹€. μˆ˜μ§‘λœ λ°μ΄ν„°λŠ” λ‚ μ§œμ™€ μ—΄ μ—λ„ˆμ§€ μ‚¬μš©λŸ‰, μœ λŸ‰μ΄μ—ˆμœΌλ©°, μˆ˜μ§‘μ΄ κ°„λ‹¨ν•œ 데이터듀을 ν™œμš©ν•˜κΈ° μœ„ν•΄ μž₯λΉ„λ₯Ό μ‚¬μš©ν•΄ 츑정이 ν•„μš”ν•œ μ™ΈκΈ° μ˜¨λ„μ™€ μŠ΅λ„, 일ꡐ차, 평균값 등은 λͺ¨λ‘ μ œμ™Έν•˜μ˜€λ‹€. μŠ€μΌ€μ€„ ν™œμš©μ„ μœ„ν•΄ λ‚ μ§œ λ°μ΄ν„°λŠ” μš”μΌλ³„(μ›”β€€ν™”β€€μˆ˜β€€λͺ©β€€κΈˆβ€€ν† β€€μΌμš”일)둜 λ‚˜λˆˆ 데이터와 주쀑(μ›”β€€ν™”β€€μˆ˜β€€λͺ©β€€ κΈˆμš”μΌ) 주말(ν† β€€μΌμš”μΌ)둜 λ‚˜λˆˆ 데이터 그리고 μ›”(Month)κ³Ό 일(Day)둜 ν‘œμ‹œν•œ λ°μ΄ν„°λ‘œ μ„ΈλΆ„ν™”ν•˜μ˜€λ‹€. 상관관계 뢄석은 Minitab을 ν™œμš©ν•œ Pearson μƒκ΄€κ΄€κ³„λ‘œ κ΅¬ν˜„λ˜μ—ˆλ‹€.

λ³Έ μ—°κ΅¬μ—μ„œλŠ” 기계 ν•™μŠ΅ 쀑 μ—λ„ˆμ§€ 및 ν™˜κ²½ 예츑 μ—°κ΅¬μ—μ„œ 쓰이고 μžˆλŠ” ANN(Artificial Neural Network)κ³Ό SVR(Support Vector Regression) μ•Œκ³ λ¦¬μ¦˜μ„ μ΄μš©ν•˜μ—¬ 열병합 κ³΅λ™μ£Όνƒμ˜ λ‹€μŒ λ‚  일별 μ—΄ μˆ˜μš”λŸ‰μ„ μ˜ˆμΈ‘ν•˜μ˜€λ‹€. ν•™μŠ΅μ€ ANN 쀑 κ°€μž₯ 보편적인 ν˜•νƒœμΈ 닀쀑 λ ˆμ΄μ–΄ νΌμ…‰νŠΈλ‘ (Multi-layer Perceptron : MLP) μ•Œκ³ λ¦¬μ¦˜μ„ 톡해 μ§„ν–‰ν•˜μ˜€μœΌλ©° 정확도가 κ°€μž₯ λ†’μ•˜λ˜ 두 개의 Hidden layer ꡬ쑰둜 ꡬ성해 ν•™μŠ΅, 예츑 μ„±λŠ₯을 λΆ„μ„ν•˜μ˜€λ‹€. SVR은 SVM의 νšŒκ·€λΆ„μ„μ„ μœ„ν•΄ νŒŒμƒλœ ν˜•νƒœλ‘œ 정확도λ₯Ό 높이기 μœ„ν•΄ Linear, RBF, Polynomial μ»€λ„λ‘œ μ„ΈλΆ„ν™”ν•˜μ—¬ κ΅¬μ„±ν•˜μ˜€λ‹€. 2018λ…„ 01μ›” 01일뢀터 12μ›” 31μΌκΉŒμ§€ ν•™μŠ΅ λ°μ΄ν„°λ‘œ ν™œμš©λ˜μ—ˆμœΌλ©° 2019λ…„ 01μ›” 01일뢀터 01μ›” 29μΌκΉŒμ§€ 예츑 및 μ‹€μΈ‘ 비ꡐ λ„μΆœμ„ μœ„ν•œ 검증 λ°μ΄ν„°λ‘œ μ΄μš©λ˜μ—ˆλ‹€. λ³Έ μ—°κ΅¬μ—μ„œ μ œμ•ˆλœ λͺ¨λΈμ€ Python 3.7 μ—μ„œ μ œκ³΅ν•˜λŠ” ν•¨μˆ˜λ₯Ό 톡해 κ΅¬ν˜„λ˜μ—ˆλ‹€.

λŒ€μƒ 건물의 μ—΄ μ—λ„ˆμ§€ μˆ˜μš”λŸ‰ 검증 방법은 ASHRAE Guideline 14(16) κΈ°μ€€μœΌλ‘œ MBE(Mean Bias Error), CvRMSE(Coefficient of Variation of Root Mean Square Error)λ₯Ό μ΄μš©ν•˜μ—¬ 타당성 검정을 μ§„ν–‰ν•˜κ³ μž ν•œλ‹€.

3. μ—΄ μ—λ„ˆμ§€ μˆ˜μš”λŸ‰ 뢄석

3.1 μ—°κ°„ μ—΄ μ—λ„ˆμ§€ μˆ˜μš”λŸ‰ 뢄석

기계 ν•™μŠ΅ λͺ¨λΈμ„ ν•™μŠ΅ν•˜κ³  ν…ŒμŠ€νŠΈν•˜κΈ° μœ„ν•œ μΈ‘μ • λŒ€μƒμ€ μ—¬λŸ λ‹¨μ§€λ‘œ 이루어진 곡동주택이닀. Fig. 1은 μ•žμ„œ μ–ΈκΈ‰ν•œ κ³΅λ™μ£Όνƒμ˜ 2018λ…„ 1μ›” 1일뢀터 12μ›” 31μΌκΉŒμ§€ 일별 μ—΄ μ—λ„ˆμ§€ μˆ˜μš”λŸ‰μ˜ 2018λ…„ 연쀑 λ³€ν™”λ₯Ό λ‚˜νƒ€λ‚Έλ‹€. μΈ‘μ • λŒ€μƒμ€ 일별 μ—΄ μ—λ„ˆμ§€ μ‚¬μš©λŸ‰, μ‚¬μš© μœ λŸ‰ 그리고 μŠ€μΌ€μ€„μ΄λ©° λͺ¨λ‘ ν˜„μž₯μ—μ„œ 맀일 μΌμ •ν•œ μ‹œκ°„μ— μ‹€μΈ‘ 및 수기둜 μž‘μ„±ν•œλ‹€. Fig. 1 κ·Έλž˜ν”„λ₯Ό 보면 λ™μ ˆκΈ°μΈ 11μ›”λΆ€ν„° 4μ›”κΉŒμ§€λŠ” 10 Gcal μ΄μƒμ˜ μ—λ„ˆμ§€λ₯Ό μ‚¬μš©ν•˜μ§€λ§Œ ν•˜μ ˆκΈ°μΈ 5μ›”λΆ€ν„° 10μ›”κΉŒμ§€λŠ” 10 Gcal μ΄ν•˜μ˜ μ—λ„ˆμ§€λ§Œ μ‚¬μš©ν•˜λŠ” νŠΉμ§•μ„ λ³Ό 수 μžˆλ‹€.

Fig. 1 2018 Daily heat energy consumption pattern.
../../Resources/sarek/KJACR.2019.31.8.352/fig1.png

Table 1. Correlation analysis of heat demand

Parameter

Pearson Correlation

P-Value

Month

-0.442

0.000

Date

-0.118

0.020

Week_1 (weekdays & weekends)

-0.066

0.197

Week_2 (Mon, Tues, Wed, Thur, Fri, Sun)

-0.018

0.720

Heat Energy Demand the Previous day

0.920

0.000

Flow Energy Demand the Previous day

0.928

0.000

3.2 μ—΄ μ—λ„ˆμ§€ μˆ˜μš”λŸ‰ 상관성 뢄석

μ—΄ μ—λ„ˆμ§€ μˆ˜μš”λŸ‰ μ˜ˆμΈ‘μ— μ ν•©ν•œ μž…λ ₯ λ³€μˆ˜λ₯Ό μ‘°μ‚¬ν•˜κΈ° μœ„ν•΄ Pearson 상관관계 뢄석을 μ‹€μ‹œν•˜μ˜€λ‹€. 상관 뢄석은 λ―Έκ΅­ Minitab μ‚¬μ—μ„œ 개발된 톡계 μ†Œν”„νŠΈμ›¨μ–΄μΈ Minitab 18을 ν™œμš©ν•˜μ—¬ ν‰κ°€ν•˜μ˜€λ‹€. μ•žμ„œ μ–ΈκΈ‰ν–ˆλ“―μ΄, 이 μ—°κ΅¬μ˜ λͺ©μ μΈ νŽΈμ˜μ„±μ„ μœ„ν•΄ κΈ°κΈ° 이용 싀츑이 ν•„μš”ν•œ μ™ΈκΈ° μ˜¨λ„μ™€ μŠ΅λ„, 일ꡐ차, μ™ΈκΈ° μ˜¨λ„ 평균값 등은 λͺ¨λ‘ μ œμ™Έν•˜μ˜€λ‹€. λ³€μˆ˜ 쀑 Week_1은 주쀑(μ›”β€€ν™”β€€μˆ˜β€€λͺ©β€€κΈˆμš”일)κ³Ό 주말(ν† β€€μΌμš”μΌ)둜 λΆ„λ¦¬ν•œ 값이며 Week_2λŠ” 각 μš”μΌ(μ›”β€€ν™”β€€μˆ˜β€€λͺ©β€€κΈˆβ€€ν† β€€μΌμš”일)λ³„λ‘œ λ‚˜λˆˆ 데이터이닀.

μ—΄ μ—λ„ˆμ§€ μˆ˜μš”λŸ‰κ³Ό 각 λ³€μˆ˜λ“€μ˜ Pearson 상관관계 뢄석을 μ§„ν–‰ν•œ κ²°κ³ΌλŠ” Table 1κ³Ό κ°™λ‹€. MonthλŠ” -0.442둜 λ³€μˆ˜ 사이에 음의 관계가 μ μ ˆν•˜κ²Œ μžˆλ‹€. Date, Week_1, Week_2의 경우 0에 κ°€κΉŒμš΄ κ°’μœΌλ‘œ λ³€μˆ˜ 사이에 상관 관계가 μ—†λ‹€. Heat Energy Demand the Previous day, Flow Energy Demand the Previous dayλŠ” 1에 κ°€κΉŒμš΄ κ°’μœΌλ‘œ κ°•ν•œ μ–‘μ˜ 관계가 μžˆλ‹€. 즉, μ—λ„ˆμ§€ μ‚¬μš©λŸ‰μ΄ μ¦κ°€ν•˜λ©΄ 이 λ³€μˆ˜ λ˜ν•œ μ¦κ°€ν•˜λŠ” 상관관계λ₯Ό 가지고 μžˆλ‹€. 상관 관계가 μžˆλŠ” 데이터 Month, Heat Energy Demand the Previous day, Flow Energy Demand the Previous dayλŠ” λͺ¨λ‘ P-valueκ°€ 0.05 μ΄ν•˜μ΄λ―€λ‘œ λͺ¨λ‘ μœ μ˜ν•œ 상관관계λ₯Ό 가지고 μžˆμŒμ„ μ•Œ 수 μžˆλ‹€.

λ”°λΌμ„œ, λ³Έ μ—°κ΅¬μ—μ„œλŠ” Month, Heat Energy Demand the Previous day, Flow Energy Demand the Previous day의 μ„Έ 가지 λ³€μˆ˜λ₯Ό 기계 ν•™μŠ΅ λͺ¨λΈ μž…λ ₯ λ³€μˆ˜λ‘œ μ μš©ν•˜μ˜€λ‹€.

4. 기계 ν•™μŠ΅ 기반 μ—΄ μ—λ„ˆμ§€ μˆ˜μš”λŸ‰ 예츑 λͺ¨λΈ

4.1 기계 ν•™μŠ΅ κ°œμš”

기계 ν•™μŠ΅μ€ μ§€λ‚œ λͺ‡ μ‹­ λ…„ λ™μ•ˆ λ‹€μ–‘ν•œ 곡학 λΆ„μ•Όμ˜ 문제λ₯Ό ν•΄κ²°ν•˜κΈ° μœ„ν•΄ μ‚¬μš©λ˜μ—ˆλ‹€. μ΄λŸ¬ν•œ λ°©λ²•μ˜ λŒ€λΆ€λΆ„ λΆ„λ₯˜ 문제λ₯Ό ν•΄κ²°ν•˜κΈ° μœ„ν•΄ κ°œλ°œλ˜μ—ˆλŠ”λ°, ν˜„μž¬μ—λŠ” 건물 μ—λ„ˆμ§€ μ†ŒλΉ„ 예츑과 같은 νšŒκ·€ λ¬Έμ œκΉŒμ§€ ν™•λŒ€λ˜μ—ˆλ‹€.(17)

λ³Έ μ—°κ΅¬μ—μ„œλŠ” 데이터 기반 접근방식 쀑 ANN, SVR μ•Œκ³ λ¦¬μ¦˜μ„ μ΄μš©ν•˜λ©° λ‹€μŒ λ‚ μ˜ μ—΄ μ—λ„ˆμ§€ μ‚¬μš©λŸ‰μ„ 미리 μ˜ˆμΈ‘ν•˜μ˜€λ‹€. λ¨Όμ €, ANN은 λΈ”λž™λ°•μŠ€ 방법에 μ†ν•˜λ©°, 자체 ν•™μŠ΅ λŠ₯λ ₯ λ“± λ‹€μ–‘ν•œ κ°€λŠ₯μ„± λ•Œλ¬Έμ— μ—¬λŸ¬ μœ ν˜•μ˜ μ˜ˆμΈ‘μ— κ°€μž₯ 많이 μ‚¬μš©λ˜λŠ” 인곡지λŠ₯ λͺ¨λΈμ΄λ‹€. μ§€λ‚œ 10λ…„ λ™μ•ˆ 건물 μ—λ„ˆμ§€ 예츑 적용 κ°€λŠ₯성에 λŒ€ν•΄ 쑰사 λ˜μ—ˆμœΌλ©° λΉ„μ„ ν˜• 맀핑 λŠ₯λ ₯으둜 건물의 λΆ€ν•˜λ₯Ό μ˜ˆμΈ‘ν•˜κΈ° μœ„ν•΄ 널리 적용되고 μžˆλ‹€.(18, 19, 20) SVM은 μš”μ¦˜ 인기λ₯Ό 끌고 μžˆλŠ” 기계 ν•™μŠ΅ 방식이닀. μ†Œμœ„ λΉ„λͺ¨μˆ˜ νšŒκ·€ λͺ¨λΈλ‘œμ„œ λ³€μˆ˜λ“€μ€ 미리 μ •μ˜λ˜μ–΄ μžˆμ§€ μ•ŠμœΌλ©°, μ‚¬μš©λœ ν•™μŠ΅ 데이터에 따라 달라진닀. λ‹€λ₯Έ 인곡지λŠ₯ μ•Œκ³ λ¦¬μ¦˜κ³Ό μœ μ‚¬ν•˜κ²Œ SVM을 λΆ„λ₯˜ν•˜κΈ° μœ„ν•΄ μ‚¬μš©ν•˜λŠ” κ²½μš°κ°€ λ§Žλ‹€. SVM의 λ°œλ‹¨μ€ 1964/65년에 Vpanik에 μ˜ν•΄ λΆ„λ₯˜ 문제λ₯Ό ν•΄κ²°ν•˜κΈ° μœ„ν•΄ κ°œλ°œλ˜μ–΄ μ™”μ§€λ§Œ μ‹€μš©μ μΈ μ μš©μ— 적합 ν•˜μ§€ μ•Šλ‹€λŠ” 의견이 널리 퍼져 μžˆμ—ˆλ‹€. ν•˜μ§€λ§Œ μ΅œκ·Όμ—λŠ” νšŒκ·€ μ˜μ—­κΉŒμ§€ ν™•μž₯λ˜μ–΄ 이λ₯Ό SVR(Support Vector Regression)이라고 ν•˜λ©°(21) λ‹€λ₯Έ 톡계 λͺ¨λΈκ³Ό μœ μ‚¬ν•œ λ˜λŠ” 더 λ‚˜μ€ κ²°κ³Όλ₯Ό 보여주고 μžˆλ‹€.(22)

ANNκ³Ό SVR이 두 가지 톡계 κΈ°λ²•μ—λŠ” 차이가 μžˆλ‹€. ANN은 μ‹€μ œ 적용과 κ΄‘λ²”μœ„ν•œ μ‹€ν—˜μ—μ„œ 이둠에 이λ₯΄κΈ° κΉŒμ§€ μ—­μˆœμœΌλ‘œ μ§„ν–‰λ˜μ—ˆμœΌλ©°, SVR은 μ΄λ‘ μ—μ„œ κ°œλ°œλ˜μ—ˆκ³ , μ‹€μ œμ™€ μ‹€ν—˜μ—μ„œ 이후에 κ΅¬ν˜„λ˜μ—ˆλ‹€. λ‹€μ–‘ν•œ μ„ ν–‰ μ—°κ΅¬λ‘œ 예츑 κ°€λŠ₯성을 증λͺ…ν–ˆλŠ”λ°, μ„ ν–‰ μ—°κ΅¬μ—μ„œ 사무싀 건물의 냉각 λΆ€ν•˜ μ˜ˆμΈ‘μ„ μœ„ν•΄ 두 λͺ¨λΈμ„ λΉ„κ΅ν–ˆκ³ ,(23) 건물 μ „λ ₯ μ†ŒλΉ„ μ˜ˆμΈ‘μ„ μœ„ν•œ 두 λͺ¨λΈ μ μš©μ— λŒ€ν•œ κ²€ν† (24)뿐만 μ•„λ‹ˆλΌ νƒœμ–‘μ—΄ 곡기 λ‚œλ°©κΈ° 효율 μ˜ˆμΈ‘μ— 성곡적 으둜 μ‚¬μš©λ˜μ—ˆλ‹€.(25) 건물 μ „λ ₯ μ†ŒλΉ„ μ˜ˆμΈ‘μ„ μœ„ν•œ 두 μ•Œκ³ λ¦¬μ¦˜ μ μš©μ— λŒ€ν•œ κ²€ν† (26)λŠ” 많이 이루어 μ‘Œμ§€λ§Œ 건물 μ—λ„ˆμ§€ μ‚¬μš©λŸ‰ μ˜ˆμΈ‘μ— λŒ€ν•œ λͺ¨λΈμ€ μ•„μ§κΉŒμ§€ λΆ€μ‘±ν•œ 싀정이닀.

λ³Έ μ—°κ΅¬μ—μ„œ μ‚¬μš©ν•œ SVR(26, 27)κ³Ό ANN의 ν•™μŠ΅ 및 μ˜ˆμΈ‘μ€ Pedregosaκ°€ κ°œλ°œν•œ Pythonκ³Ό μ˜€ν”ˆ μ†ŒμŠ€ 라이브 러리λ₯Ό 기반으둜(28) Numpy, Pandas, Matplotlib, Scikit-learn 그리고 Kerasλ₯Ό μ΄μš©ν•΄ 데이터 뢄석을 κ΅¬ν˜„ν•˜μ˜€λ‹€. λ³Έ μ—°κ΅¬μ—μ„œ ν™œμš©ν•œ ANN은 인곡신경망 λͺ¨λΈ 쀑 κ°€μž₯ 기본적인 ꡬ쑰인 Rosenblatt(1958)의 νΌμ…‰νŠΈλ‘ (Perceptron) λͺ¨λΈμ„ μ μš©ν–ˆλ‹€. μž…λ ₯μΈ΅, 정확도가 λ†’μ•˜λ˜ 두 개의 은닉측, 좜λ ₯측으둜 κ΅¬μ„±λœ 닀쀑 λ ˆμ΄μ–΄ 신경망을 이용 ν•˜μ˜€λ‹€.(29) SVM λͺ¨λΈμ—μ„œ νšŒκ·€ μ˜μ—­μ„ μœ„ν•΄ νŒŒμƒλœ SVR(Support Vector Regression) λͺ¨λΈμ„ μ΄μš©ν–ˆλ‹€. 정확도가 κ°€μž₯ λ†’μ•˜λ˜ Cλ₯Ό 1,000으둜 μ„€μ •ν•˜κ³  λ₯Ό 0.01둜 μ„€μ •ν•˜μ—¬ μ§„ν–‰ν•œλ‹€. λ˜ν•œ, Linear, RBF(radial basis function network, RBF), Polynomial μ„Έ 가지 μ»€λ„λ‘œ λΆ„λ₯˜ν•˜μ—¬ μ—΄λ³‘ν•©λ°œμ „ μ‹œμŠ€ν…œ 예츑 κ°’μ˜ 정확도λ₯Ό λ†’μ΄κ³ μž 진행 ν–ˆλ‹€.

4.2 μ—΄ μ—λ„ˆμ§€ μˆ˜μš”λŸ‰ 예츑 검증

μ—΄ μ—λ„ˆμ§€ μˆ˜μš”λŸ‰ μ˜ˆμΈ‘μ„ κ²€μ¦ν•˜κΈ° μœ„ν•œ λ°μ΄ν„°λŠ” 일별 μ—΄λŸ‰, μœ λŸ‰μ΄λ©° λͺ¨λ‘ ν˜„μž₯μ—μ„œ 맀일 μΌμ •ν•œ μ‹œκ°„μ— μ‹€μΈ‘ 및 수기둜 μž‘μ„±λœ 데이터이닀. 2018λ…„ 01μ›” 01일뢀터 12μ›” 31μΌκΉŒμ§€ ν•™μŠ΅ λ°μ΄ν„°λ‘œ ν™œμš©λ˜μ—ˆμœΌλ©° 2019λ…„ 01μ›” 01일뢀터 01μ›” 29μΌκΉŒμ§€ 예츑 및 μ‹€μΈ‘ 비ꡐ λ„μΆœμ„ μœ„ν•œ 검증 λ°μ΄ν„°λ‘œ μ΄μš©λ˜μ—ˆλ‹€. λ„μΆœλ˜λŠ” μ—΄ μ—λ„ˆμ§€ μˆ˜μš”λŸ‰ 예츑 값을 ν‰κ°€ν•˜κΈ° μœ„ν•΄ CvRMSE(Coefficient of Variation of Root Mean Square Error)와 MBE(Mean Bias Error)λ₯Ό μ΄μš©ν•˜μ—¬ 정확도λ₯Ό ν‰κ°€ν•˜μ˜€λ‹€. MBEλŠ” μ˜ˆμΈ‘κ°’μ˜ 치우친 정도λ₯Ό μ˜λ―Έν•˜λ©°, CvRmseλŠ” λΆ„μ‚° 정도λ₯Ό 톡해 였차λ₯Ό λΆ„μ„ν•˜λŠ” λ°©λ²•μœΌλ‘œ λͺ¨λ‘ \%둜 λ‚˜νƒ€λ‚œλ‹€. Table 2μ—μ„œ ASHRAE Guideline 14μ—μ„œ μ œκ³΅ν•˜λŠ” 기쀀을 μ‚¬μš©ν•˜μ—¬ λ‹€μŒ 식(1), 식(2)와 같이 CvRMSE(Coefficient of Variation of Root Mean Square Error)와 MBE(Mean Bias Error)λ₯Ό μ΄μš©ν•˜μ—¬ 정확도λ₯Ό ν‰κ°€ν•˜μ˜€λ‹€.

Table 2. Acceptable tolerances defined by ASHRAE Guideline 14

Parameter

CvRMSE

MBE

Monthly

10%

Β±5

Hourly

30%

Β±10

(1)
$Cv({R MSE})[\%]=\dfrac{{R MSE}}{{A}}\times 100$

(2)
$MBE[\%]=\dfrac{\sum_{Period}(S-M)}{\sum_{Period}M}$

5. 비ꡐ κ²°κ³Ό

μ•žμ„œ μ–ΈκΈ‰ν–ˆλ“―μ΄, μ œμ•ˆλœ λͺ¨λΈμ€ 2018λ…„ 01μ›” 01일뢀터 2019λ…„ 01μ›” 29μΌκΉŒμ§€ μΈ‘μ •λœ 일별 데이터이닀. μ—¬κΈ°μ„œ 과거의 일별 μ—λ„ˆμ§€ μ‚¬μš©λŸ‰ 변동 νŒ¨ν„΄μ„ λΉ„μŠ·ν•˜κ²Œ μœ μΆ”ν•˜λŠ” λͺ¨λΈμ„ κ΅¬μΆ•ν•˜κ²Œ 될 경우 λ‹€μŒ λ‚ μ˜ μ—΄ μ—λ„ˆμ§€ μ‚¬μš©λŸ‰μ„ μ˜ˆμΈ‘ν•  수 μžˆλ‹€. λ”°λΌμ„œ, λ³Έ μ—°κ΅¬μ—μ„œλŠ” 예츑 λͺ¨λΈμ— μ•žμ„œ λͺ¨λΈμ˜ ν•™μŠ΅ μ„±λŠ₯을 λ¨Όμ € λΆ„μ„ν•˜μ˜€λ‹€. 비ꡐλ₯Ό μœ„ν•΄ ANN은 인곡신경망 λͺ¨λΈ 쀑 κ°€μž₯ 기본적인 ꡬ쑰인 νΌμ…‰νŠΈλ‘  λͺ¨λΈμ— μž…λ ₯μΈ΅, 두 개의 hidden layer, 좜λ ₯측으둜 κ΅¬μ„±λœ 닀쀑 λ ˆμ΄μ–΄ νΌμ…‰νŠΈλ‘  신경망을 μ΄μš©ν•˜μ˜€λ‹€. SVM λͺ¨λΈμ—μ„œ νšŒκ·€ μ˜μ—­μ„ μœ„ν•΄ νŒŒμƒλœ SVR (Support Vector Regression) λͺ¨λΈμ„ μ΄μš©ν–ˆλŠ”λ° Linear, RBF(radial basis function network, RBF), Polynomial μ„Έ 가지 μ»€λ„λ‘œ λΆ„λ₯˜ν•˜μ—¬ μ§„ν–‰ν•˜μ˜€λ‹€.

Table 3μ—λŠ” 각 두 λͺ¨λΈ 예츑 κ²°κ³Όλ₯Ό λ‚˜νƒ€λ‚΄μ—ˆλ‹€. Fig. 2λŠ” ANN을 μ΄μš©ν•΄ μ˜ˆμΈ‘ν•œ 결과와 μ‹€μΈ‘ λ°μ΄ν„°μ˜ 비ꡐ κ·Έλž˜ν”„μ΄λ©°, Fig. 3λŠ” SVR을 μ΄μš©ν•œ 각 μ»€λ„μ˜ μ˜ˆμΈ‘κ°’κ³Ό μ‹€μΈ‘κ°’μ˜ 비ꡐλ₯Ό κ·Έλž˜ν”„λ‘œ λ‚˜νƒ€λƒˆλ‹€. ANN은 CvRMSE 8.75%, MBE 7.13%의 였차λ₯Ό λ³΄μ˜€λ‹€. SVR은 3가지 컀널 쀑 Polynomial 컀널이 κ°€μž₯ 정확도가 λ†’μ•˜μœΌλ©° Linear 컀널은 CvRMSE 10.40%, MBE -1.29%μ˜€μœΌλ©°, RBF 컀널은 CvRMSE 9.94%, MBE 3.71%, Polynomial 컀널은 CvRMSE 8.93%, MBE -3.16%둜 기쀀에 λ§Œμ‘±ν•˜λŠ” κ²°κ³Όλ₯Ό λ³΄μ˜€λ‹€.

Table 3. Learning error result of ANN and SVR

ANN

SVR

Linear

RBF

Polynomial

CvRMSE

8.7490

10.3970

9.9411

8.9261

MBE

7.1298

-1.2917

3.7073

-3.1589

Fig. 2 Validation of ANN.
../../Resources/sarek/KJACR.2019.31.8.352/fig2.png

Fig. 3 Validation of SVR.
../../Resources/sarek/KJACR.2019.31.8.352/fig3.png

6. κ²° λ‘ 

ν˜„μž¬ 각 μ„ΈλŒ€λ‘œ μ—΄ μ—λ„ˆμ§€λ₯Ό κ³΅κΈ‰ν•˜λŠ” λŒ€μƒ μ—΄λ³‘ν•©λ°œμ „ μ‹œμŠ€ν…œμ˜ 운영 방식은 μ™ΈκΈ° μ˜¨λ„μ— λ”°λ₯Έ ν”„λ‘œκ·Έλž¨μ„ μ΄μš©ν•˜μ—¬ μš΄μ „ν•˜κ³  μžˆλ‹€. μ‚¬μš©μžμ˜ μ—΄ μ‚¬μš©λŸ‰ 및 μ™ΈκΈ° μ˜¨λ„μ— 따라 λ³€μœ λŸ‰, λ³€μ˜¨λ„ 곡급방식을 μ΄μš©ν•˜λ©°, 각 μ™ΈκΈ°μ˜¨λ„ -10℃, -5℃, 0℃, 5℃, 10℃에 따라 λ‚œλ°©κ³΅κΈ‰μ˜¨λ„λ₯Ό 60℃, 56℃, 53℃, 49℃, 45℃도 λ“±μœΌλ‘œ μ„€μ •ν•˜μ—¬ μ™ΈκΈ°μ˜¨λ„λ³„ 적정 λ‚œλ°©μ˜¨λ„λ‘œ 단지별 싀정에 맞게 μ‘°μ •ν•˜λŠ” 방식을 μ±„νƒν•˜κ³  μžˆλ‹€. μ΄λŸ¬ν•œ 방식은 μ™ΈκΈ° μ˜¨λ„λ₯Ό ν˜„μž₯μ—μ„œ μ‹€μ‹œκ°„μœΌλ‘œ μΈ‘μ •ν•΄μ•Ό ν•˜λ©°, ν•˜λ£¨ μ „ μš΄μ „ κ³„νšμ„ μ„Έμš°κΈ°μ— 어렀움이 λ”°λ₯Έλ‹€. λ˜ν•œ μ •ν™•ν•œ μˆ˜μš”λŸ‰μ΄ μ•„λ‹ˆκΈ°μ— μ˜€μ°¨κ°€ λ°œμƒν•œλ‹€. λ‹€λ₯Έ λ°©λ²•μœΌλ‘œ κΈ°μƒμ²­μ˜ 데이터λ₯Ό κ°€μ Έμ˜¬ 경우 ν˜„μž₯κ³ΌλŠ” μ˜€μ°¨κ°€ λ°œμƒν•  수 μžˆλ‹€. λ”°λΌμ„œ, μ‚¬μš©μžμ˜ μŠ€μΌ€μ€„κ³Ό ν•„μš” 여건에 맞으며 νŽΈμ˜μ„±μ„ κ³ λ €ν•œ 졜적의 μš΄μ „ λͺ¨λ“œλ₯Ό μ°Ύμ•„ 효율 적인 μš΄μ „ λ°©μ•ˆμ„ λͺ¨μƒ‰ν•΄μ•Ό ν•œλ‹€. λ³Έ μ—°κ΅¬μ—μ„œλŠ” μ™ΈκΈ° μ˜¨λ„λ₯Ό μ œμ™Έν•˜κ³  κ°„λ‹¨ν•˜κ²Œ μΈ‘μ •ν•  수 μžˆλŠ” λ³€μˆ˜λ‘œ λ‹€μŒ λ‚  μ—΄ μ—λ„ˆμ§€ μˆ˜μš”λŸ‰μ„ 미리 μ˜ˆμΈ‘ν•˜μ—¬ λ‚­λΉ„λ˜λŠ” 폐열을 μ΅œμ†Œν™” ν•˜κ³ μž 연ꡬλ₯Ό μ œμ•ˆν•˜μ˜€μœΌλ©°, 예츑 정확도λ₯Ό 높이기 μœ„ν•΄ 기계 ν•™μŠ΅ 쀑 ANN, SVR(Linear, RBF, Polynomial)을 ν™œμš©ν•˜μ˜€λ‹€. ν•™μŠ΅μ„ μœ„ν•΄ μ‚¬μš©λœ μž…λ ₯λ°μ΄ν„°λŠ” μ „λ‚  μ—΄ μ—λ„ˆμ§€ μ‚¬μš©λŸ‰, μ „λ‚  μœ λŸ‰ 그리고 μ›” λ°μ΄ν„°λ‘œ 비ꡐ적 λ‹¨μˆœν•œ 데이터λ₯Ό μ‚¬μš©ν•˜μ˜€μœΌλ©° μ‹€μ œ μ‚¬μš©ν•˜κ³  μžˆλŠ” κ³΅λ™μ£Όνƒμ˜ μ—΄ μ—λ„ˆμ§€ μˆ˜μš”λŸ‰ 데이터λ₯Ό μ‚¬μš©ν•˜μ˜€λ‹€. λ„μΆœλ˜λŠ” μ—΄ μ—λ„ˆμ§€ μˆ˜μš”λŸ‰ 예츑 값을 ν‰κ°€ν•˜κΈ° μœ„ν•΄ CvRMSE(Coefficient of Variation of Root Mean Square Error)와 MBE(Mean Bias Error)λ₯Ό μ΄μš©ν•˜μ—¬ 정확도λ₯Ό ν‰κ°€ν•˜μ˜€λ‹€. κ·Έ κ²°κ³ΌλŠ” λ‹€μŒκ³Ό κ°™λ‹€.

(1) μ—΄ μ—λ„ˆμ§€ μˆ˜μš”λŸ‰ 상관관계 뢄석을 진행해본 κ²°κ³Ό 주쀑과 주말을 λ‚˜λˆˆ 주와 각 μš”μΌλ³„λ‘œ λ‚˜λˆˆ Date, Week_1, Week_2의 경우 Pearson 상관 관계 κ³„μˆ˜κ°€ 0에 κ°€κΉŒμš΄ κ°’μœΌλ‘œ λ³€μˆ˜ 사이에 상관관계가 μ—†λ‹€. μ΄λŠ” 열병합 λ°œμ „μ‹œμŠ€ν…œμ„ μ‚¬μš©ν•˜λŠ” 곡동주택 μž¬μ‹€μžλ“€μ€ 주별 λ˜λŠ” 일별 주기적인 νŠΉμ„±μ— 따라 μ‹€λ‚΄ μ˜¨λ„λ₯Ό μ‘°μ •ν•˜κΈ° λ³΄λ‹€λŠ” μΌμ •ν•œ μ‹€λ‚΄ μ˜¨λ„λ‘œ μœ μ§€ν•˜λŠ” νŠΉμ§• λ•Œλ¬Έμ— λ‚˜νƒ€λ‚œ 결과둜 νŒλ‹¨λœλ‹€.

(2) μ—΄ μ—λ„ˆμ§€ μˆ˜μš”λŸ‰ 상관 관계 뢄석을 톡해 MonthλŠ” -0.442둜 음의 관계가 μ μ ˆν•˜κ²Œ 있으며, 이전 μ‚¬μš© μ—΄λŸ‰κ³Ό μœ λŸ‰μ€ 1에 κ°€κΉŒμš΄ κ°’μœΌλ‘œ κ°•ν•œ μ–‘μ˜ 상관관계가 μžˆλ‹€. Month와 μ „λ‚  μœ λŸ‰, μ „λ‚  μ—΄ μ—λ„ˆμ§€ μ‚¬μš©λŸ‰μ€ λͺ¨λ‘ μœ μ˜ν•œ μƒκ΄€κ΄€κ³„λ‘œ λ‚˜νƒ€λ‚¬λ‹€. μ΄λŠ” μ „λ‚  μ—΄ μ—λ„ˆμ§€ μ‚¬μš©λŸ‰, μœ λŸ‰ λ˜λŠ” μ›” λ°μ΄ν„°λŠ” λ‹€μŒ λ‚ μ˜ μ—΄ μ—λ„ˆμ§€ μ‚¬μš©λŸ‰μ— 영ν–₯을 주기에 μž…λ ₯ λ³€μˆ˜λ‘œ μ μš©λ˜κΈ°μ— μΆ©λΆ„ν•˜λ‹€κ³  νŒλ‹¨λœλ‹€.

(3) μ„ μ •λœ μž…λ ₯ 데이터λ₯Ό 톡해 기계 ν•™μŠ΅μ„ μ§„ν–‰ν•œ κ²°κ³Ό ANN은 CvRMSE 8.75%, MBE 7.13%의 였차λ₯Ό λ³΄μ˜€λ‹€. SVM은 3가지 컀널 쀑 Polynomial 컀널이 κ°€μž₯ 정확도가 λ†’μ•˜μœΌλ©° Linear 컀널은 CvRMSE 10.40%, MBE -1.29%μ˜€μœΌλ©°, RBF 컀널은 CvRMSE 9.94%, MBE 3.71%, Polynomial 컀널은 CvRMSE 8.93%, MBE -3.16%둜 기쀀에 λ§Œμ‘±ν•˜λŠ” κ²°κ³Όλ₯Ό λ³΄μ˜€λ‹€. λ”°λΌμ„œ, 열병합 λ°œμ „μ‹œμŠ€ν…œμ„ μ‚¬μš©ν•˜λŠ” κ³΅λ™μ£Όνƒμ—μ„œ μ™ΈκΈ° μ˜¨λ„, μŠ΅λ„ λ“± μ‹€μΈ‘ λ˜λŠ” 예보 데이터λ₯Ό ν™œμš©ν•˜μ§€ μ•Šμ•„λ„ λ‹€μŒ λ‚ μ˜ μ—΄ μ—λ„ˆμ§€ μ‚¬μš©λŸ‰μ„ μ˜ˆμΈ‘ν•  수 μžˆλŠ” κ²ƒμœΌλ‘œ νŒλ‹¨λœλ‹€.

λ³Έ 연ꡬ 결과둜 μ—΄ μ—λ„ˆμ§€ μ‚¬μš©λŸ‰μ„ 미리 μ˜ˆμΈ‘ν•˜μ—¬ ν•˜λ£¨ λ‹¨μœ„λ‘œ 미리 운영 방식을 κ³„νšν•΄ μ μš©ν•œλ‹€λ©΄ μ™ΈκΈ° μ˜¨λ„λ₯Ό μ΄μš©ν•˜μ—¬ μš΄μ „μ„ ν•˜λŠ” κΈ°μ‘΄κ³Ό 달리, κ³„νšμ μΈ μš΄μ „μœΌλ‘œ μ—΄ μ—λ„ˆμ§€ 곡급과 μ‚¬μš©λŸ‰ 차이λ₯Ό μ΅œμ†Œν™”ν•˜μ—¬ ν™˜κ²½μ , 효율적으둜 합리적인 κ²°κ³Όλ₯Ό λ„μΆœν•  수 μžˆλ‹€. λ˜ν•œ μ‚¬μš©μžμ˜ λ§Œμ‘±λ„λ₯Ό 높일 뿐만 μ•„λ‹ˆλΌ μ—΄ κ΄€λ¦¬μž μ—κ²Œ μ›ν™œν•œ μ˜μ‚¬κ²°μ • νŒλ‹¨μ— 도움을 쀄 수 μžˆλ‹€. λ‹€λ§Œ λ³Έ 연ꡬ κ²°κ³Ό λ„μΆœμ„ μœ„ν•œ 데이터 μˆ˜μ§‘ μ‹œ μŠ€μΌ€μ€„ 및 μ „λ‚  μ—΄ μ—λ„ˆμ§€ μ‚¬μš©λŸ‰ λ°μ΄ν„°ν™”λŠ” μ‹€μΈ‘ 및 수기둜 μž‘μ„±ν•˜κΈ°μ— λ²ˆκ±°λ‘œμ›€μ΄ λ”°λ₯Έλ‹€. λ˜ν•œ, 예츑 λͺ¨λΈμ„ 개발 ν•˜λŠ” 기초 μ—°κ΅¬λ‘œμ„œ 열병합 λ°œμ „μ‹œμŠ€ν…œμ„ μ‚¬μš©ν•˜λŠ” νŠΉμ • 건물의 데이터λ₯Ό μ‚¬μš©ν•˜μ˜€λŠ”λ° 싀증을 κ³ λ €ν•œ ν–₯ν›„ μ—°κ΅¬μ—μ„œλŠ” νŠΉμ • 건물이 μ•„λ‹Œ 닀양성이 ν™•λ³΄λœ μ—°κ΅¬λ‘œ μ§„ν–‰λ˜μ–΄μ•Ό ν•œλ‹€.

λ³Έ μ—°κ΅¬μ˜ κ²°κ³ΌλŠ” μ‹€μ œ μΈ‘μ •λœ μ—΄ μ—λ„ˆμ§€ μˆ˜μš”λŸ‰ 데이터λ₯Ό ν™œμš©ν•΄ μ‹ λ’°ν•  수 μžˆλŠ” μˆ˜μ€€μ˜ λ‹€μŒ λ‚  μ—΄ μ—λ„ˆμ§€ μˆ˜μš”λŸ‰μ„ μ˜ˆμΈ‘ν•  수 μžˆμ—ˆλ‹€. ν–₯ν›„ μ˜ˆμΈ‘ν•œ λͺ¨λΈμ΄ 열병합 λ°œμ „μ‹œμŠ€ν…œμ—μ„œ μ μš©ν•˜μ—¬ λ‚­λΉ„λ˜λŠ” 폐열을 μ΅œμ†Œν™”ν•˜μ—¬ μ—λ„ˆμ§€ μ ˆμ•½μ„ 도λͺ¨ν•˜κ³ , μ „λ‚  μΈ‘μ • κ°€λŠ₯ν•œ κ°„λ‹¨ν•œ 데이터듀을 μ΄μš©ν•΄ μ—΄ κ³΅κΈ‰μžλ“€μ˜ μ—΄λŸ‰ 예츑 및 운영 κ³„νšμ— 편의λ₯Ό κΈ°μ—¬ν•  κ²ƒμœΌλ‘œ κΈ°λŒ€ν•œλ‹€.

ν›„ κΈ°

1. λ³Έ μ—°κ΅¬λŠ” μ‚°μ—…ν†΅μƒμžμ›λΆ€(MOTIE)와 ν•œκ΅­μ—λ„ˆμ§€κΈ°μˆ ν‰κ°€μ›(KETEP)의 지원을 λ°›μ•„ μˆ˜ν–‰ν•œ μ—°κ΅¬κ³Όμ œμž…λ‹ˆλ‹€ (No. 20194010201850).

2. 이 λ…Όλ¬Έ(μ €μ„œ)λŠ” 2019년도 μ—°μ„ΈλŒ€ν•™κ΅ μ—°κ΅¬λΉ„μ˜ 지원을 λ°›μ•„ μˆ˜ν–‰λœ κ²ƒμž„(2018-22-0038).

References

1 
2018, 2030 Amendment to the GHG Reduction Roadmap and Plan for the allocation of emission allowances from 2018 to 2020, Ministry of Environment.Google Search
2 
2017, 2018 Intergrated Energy Supply Manual, KOREA ENERGY AGENCY.Google Search
3 
ASHRAE , 2015, COMBINED HEAT AND POWER DESIGN GUIDE.Google Search
4 
Joeng J., 2003, Cogeneration Technology Guidebook, Korea Energy Management Corporation.Google Search
5 
Im Y., 2010, A diagnostic simulation for the optimal system configuration of cogeneration systems, The Korean Society of Mechanical Engineers, pp. 3708-3713.Google Search
6 
Kim H., 2017, Forecasting of heat demand for combined heat and power plant, Soongsil University.Google Search
7 
Song K., 2011, Heat Demand Forecasting for Local District Heating, IE Interfaces, Vol. 24, No. 4, pp. 373-378.DOI
8 
Lee J., 2015, A Study on the Deduction of Additional Key Factor for Heat Supply Forecast using the Analysis of Heat Demand Characteristics, The Society of Air-Conditioning and Refrigerating Engineers of Korea, pp. 659-662.Google Search
9 
Kim M., 2008, Development of heat demand forecasting model for district energy management system, Korean Society for Energy, pp. 193-198.Google Search
10 
Dotzauer E., 2002, Simple model for prediction of loads in district-heating system, Applied Energy, pp. 277-284.DOI
11 
Kim H., 2017, Forecasting of heat demand for combined heat and power plant, Soongsil University.Google Search
12 
Back J. K., Han J. H., 2011, Forecasting of Heat Demand in Winter Using Linear Regression Models for Korea District Heating Corporation, Korea Academy Industrial Cooperation Society, pp. 1488-1494.DOI
13 
Han D., Youn H. B., 2002, Study on Air Handling Unit Control Algorithms by Using Building Load Prediction, The Society of Air-Conditioning and Refrigerating Engineers of Korea.Google Search
14 
Jeon B., 2018, Development of Weather Forecast Models for a Short-term Building Load Prediction, Journal of the Korean Solar Energy Society, Vol. 38, No. 1, pp. 1-11.DOI
15 
2015, Practical Practice of District Heating System, KOREA DISTRICT HEATING CORP.Google Search
16 
2002, Measurement of Energy and Demand Saving, ASHRAE Guideline 14Google Search
17 
Aleksandra A. S., Jovanovic R. Z., Novakovic V. M., Nord N. M., Zivkovic B. D., 2018, Support Vector Machine for the Prediction of Heating Energy Use, Vol. 22, suppl. 4, pp. S1171-S1181.DOI
18 
Kumar R., Aggarwal R. K., Sharma J. D., 2013, Energy analysis of a building using artificial neural network : A review, Energy and Buildings, Vol. 64, pp. 352-358.DOI
19 
Kreider J. F., Wan X. A., 1991, Artificial neural network demonstration for automated generation of energy use predictors for commercial buildings, ASHRAE Transaction, Vol. 97, No. 2, pp. 775-779.Google Search
20 
Anstett M., Kreider J. F., 1992, Application of neural networking models to predict energy use, ASHRAE Transactions, No. 3672, pp. 505-517.Google Search
21 
Smola A. J., Scholkopf B., 2004, Statistics and Computing-A Tutorial on Support Vector Regression, Vol. 14, No. 3, pp. 199-222.Google Search
22 
Nguyen P. H., Kling W. L., Elmitri M., Lacarrière B., Le Corre O., 2015, Support Vector Machine in Prediction of Building Energy Demand Using Pseudo Dynamic Approach, Proceedings of Ecos 2015.Google Search
23 
Mager J., Paasche U., Sick B., 2008, Forecasting financial time series with support vector machines based on dynamic kernels, IEEE Conference on soft Computing Industrial Application, 25-27 June, Muroran, Japan, pp. 252-257.DOI
24 
Wang L., 1998, Support Vector Machines for Classification and Regression, ISIS technical report, University of Sauthampton, Sauthampton, UK.DOI
25 
Esen H., Inalli M., Sengur A., Esen M., 2008, Modeling a Ground-Coupled Heat Pump System by a Support Vector Machine, Renewable Energy, Vol. 33, No. 8, pp. 1814-1823.DOI
26 
Cortes C., Vapnik V., 1995, Support-vector networks, Machine Learning, Vol. 20, No. 3, pp. 273-297.DOI
27 
Pedregosa et al., 2011, Scikit-learn: Machine learning in Python, Journal of Machine Learning Research, Vol. 12, pp. 2825-2839.Google Search
28 
Vapnik V., 2000, The nature of statistical learning theory, springer.DOI