Mobile QR Code QR CODE : Korean Journal of Air-Conditioning and Refrigeration Engineering
Korean Journal of Air-Conditioning and Refrigeration Engineering

Korean Journal of Air-Conditioning and Refrigeration Engineering

ISO Journal TitleKorean J. Air-Cond. Refrig. Eng.
  • Open Access, Monthly
Open Access Monthly
  • ISSN : 1229-6422 (Print)
  • ISSN : 2465-7611 (Online)

References

1 
Bojic M., Yik F., Sat P., 2001, Influence of thermal insulation position in building envelope on the space cooling of high-rise residential buildings in Hong Kong, Energy Build, Vol. 33, No. 6, pp. 569-581DOI
2 
Chiraratananon S., Hien V. D., 2011, Thermal performance and cost effectiveness of massive walls under Thai climate, Energy Build, Vol. 43, No. 7, pp. 1655-1662DOI
3 
Liu J., Li W., Liu J., Wang B., 2010, Efficiency of energy recovery ventilation with various weathers and its energy saving performance in a residential apartment, Energy and Buildings, Vol. 42, No. 1, pp. 43-49DOI
4 
Zhou Y. P., Wu J. Y., Wang B., 2007, Performance of energy recovery ventilators with various weathers and temperature set-points, Energy and Buildings, Vol. 39, No. 12, pp. 1202-1210DOI
5 
Spltler J. D., Hittle D. C., Johnson D. L., Pederson C. O., 1987, A comparative study of the performance of temperature-based and enthalpy-based economy cycles, ASHRAE Transactions, Vol. 93, No. 2, pp. 13-22Google Search
6 
Kim M. Y., Kim Y. I., Chung K. S., 2011, Reduction of cooling load using outdoor air cooling, Korea Society of Geothermal Energy Engineers, Vol. 7, No. 1, pp. 51-58Google Search
7 
Son J. E., Hyun I. T., Lee J. H., Lee K. H., 2015, Comparison of cooling-energy performance depending on the economizer-control methods in a office building, Korea Journal of Air-Conditioning and Refrigeration Engineering, Vol. 27, No. 8, pp. 432-439DOI
8 
Choi B. E., Kim H. J., Cho Y. H., 2015, A study on performance evaluation of economizer type through simulation in office, Journal of KIAEBS, Vol. 9, No. 3, pp. 229-234Google Search
9 
Artmann N., Manz H., Heiselberg P., 2007, Climatic potential for passive cooling of buildings by night-time ventilation in Europe, Applied Energy, Vol. 84, No. 2, pp. 187-201DOI
10 
Artmann N., Manz H., Heiselberg P., 2008, Parameter study on performance of building cooling by night-time ventilation, Renewable Energy, Vol. 33, No. 12, pp. 2589-2598DOI
11 
Seppanen O., Fisk W., Faulkner D., 2003, Cost benefit analysis of the night-time ventilative cooling in office building, Healthy Buildings Proceedings 7th International Conference, Vol. 3, pp. 394-397DOI
12 
2000, TRNSYS Reference Manual, Madison : Solar Energy Laboratory, University of Wisconsin.Google Search
13 
1998, Society of Air-Conditioning and Refrigerating Engineers of Korea(SAREK), Weather data for KoreaGoogle Search
14 
Jeo J. I., 2008, Zero-Energy Green School Model Development Study(Ι) Report, Korean Educational Development Institute.Google Search
15 
2015, Center for Educational Statistics Information, Students per ClassGoogle Search
16 
2009, Samsung, DVM Technical Data Book Indoor UnitGoogle Search