KJACR
Korean Journal of
Air-Conditioning and Refrigeration Engineering
SAREK
Contact
ISSN : 1229-6422 (Print)
ISSN : 2465-7611 (Online)
http://journal.auric.kr/kjacr
Mobile QR Code
Korean Journal of Air-Conditioning and Refrigeration Engineering
ISO Journal Title
Korean J. Air-Cond. Refrig. Eng.
Open Access, Monthly
Open Access
Monthly
ISSN : 1229-6422 (Print)
ISSN : 2465-7611 (Online)
Online Submission
Main Menu
Main Menu
최근호
Current Issue
저널소개
About Journal
논문집
Journal Archive
목적 및 범위
Aims and Scope
편집위원회
Editorial Board
윤리규정
Research &
Publication Ethics
논문투고안내
Instructions to Authors
BM
(Business Model)
연락처
Contact Info
논문투고
Online-Submission
Journal Search
Home
Archive
2017-07
(Vol.29 No.07)
10.6110/KJACR.2017.29.7.373
Journal XML
XML
PDF
INFO
REF
References
1
Yoon J. S., Kwon O. K., Cha D. A., Bae K. J., Kim I. G., Kim M. S., Park C. W., 2016, Effects of Operation condition on the performance of Type Ⅱ LiBr-H2O absorption Heat Pump, Proceeding of SAREK, pp. 149-151
2
Kang B. H., Kim Y. I., Lee C. S., 1985, Thermal Design Analysis of an Absorption Heat Transformer for using Waste Hot Water, The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea, Vol. 14, No. 4, pp. 11-18
3
Chen J., 1995, Optimal choice of the performance parameters of an absorption heat transformer, Heat Recovery Syst. CHP, Vol. 15, No. 3, pp. 249-256
4
Chen J., 1997, Equivalent combined cycle of an endoreversible absorption heat transformer and optimal analysis of primary performance parameters, Energy Convers. Mgmt., Vol. 38, No. 7, pp. 705-712
5
Chen J., 1997, Thermodynamic analysis of the performance of a solar absorption heat transformer at maximum coefficient of performance, Int. J. Energy Res., Vol. 21, pp. 975-984
6
Qin X. Y., Chen L. G., Sun F. R., 2004, The optimal performance of an irreversible four-heat-reservoir absorption heat transformer, J. Eng. Thermophys., S. Wu, J. Chen, Vol. 25, pp. 185-188
7
Wu S. Z., Chen J. C., 2005, Parametric optimum design of an irreversible heat-transformer based on the thermo-economic approach, Appl. Energy, Vol. 80, pp. 349-365
8
Qin X., Chen L., Sun F., Wu C., 2005, Performance of an endoreversible four-heat-reservoir absorption heat-transformer with a generalized heat transfer law, Int. J. Ambient Energy, Vol. 26, pp. 171-179
9
Sun F., Qin X., Chen L., Wu C., 2005, Optimization between heating load and entropy-production rate for endoreversible absorption heat-transformers, Appl. Energy, Vol. 81, pp. 434-448
10
Eisa M. A. R., Best R., Holland R. F. A., 1986, Thermodynamic design data for absorption heat transformers-part I. Operating water-lithium bromide, J. Heat Recovery Syst., Vol. 6, No. 5, pp. 421-432
11
Wang J. G., Ma X. H., Lin H. T., Chen J. B., 2004, Thermodynamic analysis for LiBr-H2O absorption heat transformer, J. Dalian Univ. Technol., Vol. 44, pp. 366-370
12
Zebbar D., Kherris S., Zebbar S., Mostefa K., 2012, Thermodynamic optimization of an absorption heat transformer, Int. J. Refrig., Vol. 35, pp. 1393-1401
13
Guo P., Sui J., Han W., Zheng J., Jin H., 2012, Energy and exergy analyses on the off-design performance of an absorption heat transformer, Appl. Therm. Eng., Vol. 48, pp. 506-514