Mobile QR Code QR CODE : Korean Journal of Air-Conditioning and Refrigeration Engineering
Korean Journal of Air-Conditioning and Refrigeration Engineering

Korean Journal of Air-Conditioning and Refrigeration Engineering

ISO Journal TitleKorean J. Air-Cond. Refrig. Eng.
  • Open Access, Monthly
Open Access Monthly
  • ISSN : 1229-6422 (Print)
  • ISSN : 2465-7611 (Online)

References

1 
Khankari K., 2013, Role of HVAC System Configuration on Probable Flow Path of Airborne Pathogens in a Patient Room, American Society of Heating, Refrigerating, and Air-Conditioning Engineers, Inc. (ASHRAE) Transactions, Vol. 119, No. 2, pp. 1-8Google Search
2 
2019, Korea Centers for Disease Control and Prevention, Korea Health Promotion Institution, Guidelines for Assessment of Infection Control Facilities.Google Search
3 
Cho J. K., 2019, Investigation on the Contaminant Distribution with Improved Ventilation System in Hospital Isolation Rooms : Effect of Supply and Exhaust Air Diffuser Configurations, Applied Thermal Engineering, Vol. 148, No. , pp. 208-218DOI
4 
Berlanga F. A., Olmedo I., Ruiz de Adana M., Villafruela J. M., San José J. F., Castro F., 2018, Experimental Assessment of Different Mixing Air Ventilation Systems on Ventilation Performance and Exposure to Exhaled Contaminants in Hospital Rooms, Energy and Buildings, Vol. 177, No. , pp. 207-219DOI
5 
Qian H., Li Y., Nielsen P. V., Hyldgaard C. E., 2008, Dispersion of Exhalation Pollutants in A Two-bed Hospital Ward with A Downward Ventilation System, Building and Environment, Vol. 43, No. 3, pp. 344-354DOI
6 
Cheong K. W. D., Phua S. Y., 2006, Ventilation design strategy for effective removal of pollutant in the isolation room of a hospital, Building and Environment, Vol. 41, pp. 1161-1170Google Search
7 
Wan M. P., Chao C. Y. H., Ng Y. D., Sze To G. N., Yu W. C., 2007, Dispersion of Expiratory Droplets in a General Hospital Ward with Ceiling Mixing Type Mechanical Ventilation System, Aerosol Science and Technology, Vol. 41, No. 3, pp. 244-258DOI
8 
2017, Korea Centers for Disease Control and Prevention, Guidelines for Operation and Management of Isolation Unit of Nationally Designated Hospitals.Google Search
9 
US CDC, 2003, Guidelines for Environmental Infection Control in Health-Care Facilities : Recommendations of CDC and the Healthcare Infection Control Practices Advisory Committee (HICPAC)Google Search
10 
US CDC, 2005, Guidelines for Preventing the Transmission of Mycobacterium Tuberculosis in Health-Care Settings.Google Search
11 
Gupta J. K., Lin C.-H., Chen Q., 2009, Flow Dynamics and Characterization of A Cough, Indoor Air, Vol. 19, No. 6, pp. 517-525DOI
12 
Yang S., Lee G. W. M., Chen C.-M., Wu C.-C., Yu K.-P., 2007, The size and concentration of droplets generated by coughing in human subjects, Journal of Aerosol Medicine, Vol. 20, No. 4, pp. 484-494DOI
13 
Chao et al., 2009, Characterization of Expiration Air Jets and Droplet Size Distributions Immediately at the Mouth Opening, Journal of Aerosol Science, Vol. 40, No. 2, pp. 122-133DOI
14 
Duguid J. P., 1946, The Size and the Duration of Air-Carriage of Respiratory Droplets and Droplet-nuclei, Journal of Hygiene, Vol. 44, No. 6, pp. 471-479DOI
15 
Gralton J., Tovey E., McLaws M.-L., Rawlinson W. D., 2010, The Role of Particle Size in Aerosolised Pathogen Transmission : A review, Journal of infection, Vol. 62, No. 1, pp. 1-13DOI
16 
McCluskey R., Sandin R., Greene J., 1996, Detection of Airborne Cytomegalovirus in Hospital Rooms of Immunocompromised Patients, Journal of Virological Methods, Vol. 56, No. 1, pp. 115-118DOI
17 
Zhu S., Kato S., Yang J.-H., , Study on Transport Characteristics of Saliva Droplets Produced by Coughing in A Calm Indoor Environment, Building and Environment, Vol. 41, No. 12, pp. 1691-1702DOI
18 
Chen C., Zhao B., 2010, Some Questions on Dispersion of Human Exhaled Droplets in Ventilation Room: Answers from Numerical Investigation, Indoor Air, Vol. 20, No. 2, pp. 95-111DOI
19 
Guan Y., Ramesh A., Memarzadeh F., 2014, The Effects of Patient Movement on Particles Dispersed by Coughing in an Indoor Environment, Applied Biosafety, Vol. 19, No. 4, pp. 172-183DOI
20 
Kwon S.-B., Park J. H.., Jang J. Y., Cho Y. M., Park D.-S., Kim C. S., Bae G.-N., Jang A., 2012, Study on the Initial Velocity Distribution of Exhaled Air from Coughing and Speaking, Chemosphere, Vol. 87, No. 11, pp. 1260-1264DOI