Mobile QR Code QR CODE : Korean Journal of Air-Conditioning and Refrigeration Engineering
Korean Journal of Air-Conditioning and Refrigeration Engineering

Korean Journal of Air-Conditioning and Refrigeration Engineering

ISO Journal TitleKorean J. Air-Cond. Refrig. Eng.
  • Open Access, Monthly
Open Access Monthly
  • ISSN : 1229-6422 (Print)
  • ISSN : 2465-7611 (Online)

References

1 
Jeong J. W., Mumma S. A., Bahnfleth W. P., 2003, Energy conservation benefits of a dedicated outdoor air system with parallel sensible cooling by ceiling radiant panels, ASHRAE Trans, PART 2, Vol. 109, pp. 627-636Google Search
2 
Simonson C. J., Besant R. W., 1999, Energy Wheel Effectiveness : part Ⅱ-Correlations, International Journal of Heat and Mass Transfer, Vol. 42, pp. 2171-2185DOI
3 
Jeon B. H., Kim J. W., Lee S. L., Lee Y. J., Ahn Y. C., 2013, A Study on the Dew Condensation According to the Operational Conditions of a Heat-Recovery Ventilator, The Society of Air-Conditioning and Refrigerating Engineers of Korea, Vol. 25, No. 10, pp. 529-533DOI
4 
Chang H. J. Hong S. J., 2008, A Study on the Performance of Heat Recovery Ventilators for Apartment Houses, The Society of Air-Conditioning and Refrigerating Engineers of Korea, Vol. 20, pp. 36-34Google Search
5 
Kim I. G., Park W. C., 2009, A Study on Performance of Energy Recovery Ventilator under Outdoor Conditions in Korea, Journal of the Korea Academia-Industrial cooperation Society, Vol. 10, No. 1, pp. 52-57DOI
6 
Lee K., 2012, The Magazine of the Society of Air-conditioning and Refrigerating Engineers of Korea, The Society of Air-Conditioning and Refrigerating Engineers of Korea, Vol. 41, No. 10, pp. 36-43Google Search
7 
Freund S., Klein S. A., Reindl D. T., 2003, A Semi-Empirical Method to Estimate Enthalpy Exchanger Performance and a Comparison of Alternative Frost Control Strategies, HVAC & R Research, Vol. 9, No. 4, pp. 493-508DOI
8 
Kim C. H., Kim D. G., Shin B. H., Kum J. S., 2014, Study on Anti Icing Techniques for Motor Damper of Heat Recovery Ventilator in Apartment House, Journal of Korean Institute of Architectural Sustainable Environment and Building Systems, Vol. 8, No. 4, pp. 182-187Google Search
9 
Kim D. S., Kim J. W., Yee J. J., 2017, A Proposal of Condensation Prevention Method in the Heat Recovery Ventilation System according to the Supply and Exhaust Air Flow Ratio, Journal of the Regional Association of Architectural Institute of Korea, Vol. 19, No. 6, pp. 165-172Google Search
10 
Kang K. M., Kim T. Y., Tae K. E., Kim K. C., Lee Y. G., 2018, Experimental Study on Optimal Operation Strategies for Inner Return Energy Recovery Ventilator, Korea Institute of Ecological Architecture and Environment, Vol. 18, No. 1, pp. 97-104Google Search
11 
Kim W. J., Kim H. J., Yoon D. S., Jeong J. W., 2016, Regional Preheat Coil Capacity Estimation for Preventing Condensation in Sensible Heat or Energy Recovery Ventilators, Architectural Institute of Korea, Vol. 10, pp. 105-112DOI
12 
Kim W. J. Jeong J. W., 2017, Determination of Preheat Coil Capacity in an Energy Recovery Ventilator Considering the Differences in Sensible and latent Effectiveness Values, Korea Institute of Architectural Sustainable Environment and Building Systems, Vol. 11, No. 3, pp. 197-202Google Search
13 
Nasr M. R., Simonson C. J., Experimental Measurement of Frosting Limits in Cross-Flow Air-to-Air Energy Exchangers, ASHRAE Transactions, Vol. 123, pp. 174-181Google Search
14 
Choi Y. H., Song D. S., Seo D. H., Kim J. W., 2018, Analysis of the variable heat exchange efficiency of heat recovery ventilators and the associated heating energy demand, Energy & Buildings, Vol. 172, pp. 152-158DOI