Title Structural Behaviour of Connections between RC Column and TEC BEAM
Authors 주영규 ; 김도현 ; 김명한 ; 김상대
Page pp.45-52
ISSN 12269107
Keywords TEC BEAM ; Composite beam ; TEC-BEAM ; Limit State Design ; Shear Stud ;
Abstract The TEC Beam which can reduce the story height of a building is a composite beam composed of structural tee, precast concrete, and cast-in-site reinforced concrete slab. The previous test of this new type of proposed system was performed for simple beams and it showed a good structural behavior.
The connection between TEC Beam and RC Column is designed as a moment connection as it is commonly used in Korea, which has to be proved for the field application. For a mechanism to transfer the force that occurred in the lower part of TEC Beam to the RC column, the TEC Beam is connected at both sides of column with a plate through the column.
In this paper, two specimens are experimentally investigated to make sure the structural behavior of the proposed connection system. The parameter is a spacing of shear stud on the web. It could be concluded that the proposed connection system shows a good structural behavior and is applicable to the filed.