Title |
A Study on the Influence upon Foor Impact Sound Level by the Tire Air Pressure of Standard Heavy-Weight Impact Source |
Keywords |
Floor Impact Sound ; Floor Impact Sound Insulation ; Standard Heavy-weight Impact Source ; Air Pressure |
Abstract |
The tire air pressure of standard heavy-weight impact source when testing floor impact sound is a factor having very important influence on the test result. Therefore, in this paper we made the experiment on impact force characteristics with adjusting the tire air pressure. And we found that how much error occurred as the tire air pressure was against reference air pressure. As a result, it showed that floor impact sound level could lowered 2~3dB in proportion as the tire air pressure dropped 0.5kgf/cm2. For the accurate evaluation about floor impact sound level in the apartment housings, the tire air pressure of standard heavy-weight impact source must be corrected by prescription. |