Title |
A Study on the Evaluation of Lighting Performance in a Workstation Space |
Authors |
Kim Young-Min ; Kim Han-Seong ; Kim Chang-Seoun ; Kim Kang-Soo |
Keywords |
워크스테이션 ; 작업면 조도 ; 균제도 ; 레디언스워크스테이션 ; 작업면 조도 ; 균제도 ; 레디언스 |
Abstract |
The purpose of this study was to provide the visual evaluation data in a workstation space when different lighting types were applied. For the performance evaluation, Radiance program was used for simulations, and the mock-up room(15.0x11.6x3m) was used for the actual test.?? The results of this study were as follows; 1) When the indirect lighting simulation data using Radiance??was compared with the actual data in a small workstation space, there was a 6.5% difference. Therefore, Radiance program was proved to be useful for the evaluation of lighting performance. 2) The results show that the straddled layout has higher light levels (higher light ratio (%)) and the centered layout condition has lower light levels (lower light ratio (%)) in most cases. 3) Also, the results??show that the indirect luminaires and the straddled layouts provide higher uniformity, whereas the direct luminaires and centered layouts have lower uniformity. |