Title Equivalent Linear System of Tuned Liquid Column Damper for MDOF Building
Authors KIm Hyoung-Seop ; Min Kyung-Won ; Lee Sang-Hyun
Page pp.35-42
ISSN 12269107
Keywords tuned liquid column damper ; equivalent linear system ; harmonic load
Abstract This paper presents equivalent linear system for 76-story benchmark building with nonlinear tuned liquid column damper (TLCD). The response characteristic of benchmark building for the deterministic wind loads is investigated. And then, the equivalent linear system is obtained first in terms of equivalent linear damping and second in terms of equivalent single degree of freedom system. Numerical results show that these equivalent linear systems can almost exactly predict the controlled structural responses when compared with the nonlinear TLCD system. Finally, an equation for estimating the peak response of structure subjected to harmonic load is derived. This equation does not require any iteration process which is essential in the analysis using equivalent linear system for TLCD.