Title |
The Vibration Performance Experiment of Tuned Liquid Damper and Tuned Liquid Column Damper |
Keywords |
Tuned liquid damper ; Tuned liquid column damper ; Passive control device |
Abstract |
Wind induced oscillations of tall buildings have been of interest to engineering for a long time. Fundamental study of??vibration control of a tall building based on passive and active control method. Most effective of Wind-induced vibration control of a tall building using passive control devices. TLD and TLCD??is kind of passive mechanical damper which relies on the sloshing liquid in a rigid tank.??The Tuned liquid damper(TLD) and Tuned liquid column damper(TLCD) have been successfully employed in practical to mitigation undesirable structural vibrations. This TLD and TLCD is attributable to several potential advantages - low costs; easy to install in existing structures; effective even for small-amplitude vibrations. In this paper, the shaking table experiments were conducted to investigate the characteristics of water sloshing motion in??TLD(rectangular, circular) and TLCD. |