Title |
A Study of Root Resistance Test Concerning Waterproofing Without Root Barrier for Green Roof System |
Authors |
Oh Sang-Keun ; Bae Kee-Sun ; Kwak Kyu-Sung ; Cho Il-Kyu ; Kwon Shi-Won |
Keywords |
Green Roof ; Waterproofing ; Root-resistance ; Root barrier |
Abstract |
Recently, Technology for green roof system has been adapted within limit, according to lack of government support and unconcern of building engineer. Significantly, waterproofing technology has been constructed as it stands existing materials and construction methods, as unconsidered methods under greening circumstance, moreover, it can be occurred to extensive repair construction in a long term. For that reason, this paper will focus on the improvement of root resistance giving most attention to its most provocative and problematic in green roof system. In the following, we will give a brief general analysis and root resistance test for waterproofing system..?? First of all, we analysis a application of example, technical present for waterproofing in the green roof through the field study. we put some waterproofing materials to the root resistance test without construct root barrier, after 3 months, observe the result of this test. Result of the above test, to make good performance for waterproofing in the green roof, we find that it is obviously need to construct root barrier and systematize waterproofing method of construction. |