Title A Study on the Insulation Performance Evaluation of Triple Glazing Window System by U-Value Sensitivity Analysis
Authors Yoon Jong-Ho ; Park Jae-Sung ; Kim Byoung-Soo ; Hong Sung-Chul
Page pp.159-166
ISSN 12269093
Keywords U-Value ; Frame ; Spacer ; Low-e Glass ; Triple Glazing Window System
Abstract Window System has a problem with insulation on building wall comparison with other portions. Recently, in all over the world, technologies and research for improvement of insulation performance with window system were actively studied. This study has been considered about components of window system and evaluated insulation performance of triple window system through the tests of U-Value of window system and simulated model. It was evaluated window system that widely used in domestic or overseas. Therm5.0 and Window5.0 were used for simulation available for heat analysis from stationary state of two-dimensional simulated model. As a result, the best components of each portion on window system were PVC frame, Plastic spacer and Low-e glass and the super insulation window system was triple glazing window system applied these components. The U-Value of this super insulation triple window system was 1.297 W/㎡K and it will be expected to save energy window system.