Title A Study on Possibility of Securing the Way of Cross Ventilation about Design Parameters of Apartments
Authors Kim Hwan-Yong
Page pp.245-252
ISSN 12269093
Keywords Indoor Thermal Environment ; Design Parameters ; ESP-r CFD ; The Way of Cross Ventilation
Abstract When designing the apartment house, natural ventilation has been accepted for comfortable environment and saving energy for cooling load. The generation of indoor air is entering direction, the height and opening the size and layout, interior space and the compartment by the changes. Therefore, in this study and the direction of the apartment floors indoor thermal environment based on the measurement, ventilation, and a comparative analysis of performance, ESP-r CFD using indoor air affects the design parameters by changing the effective purpose of the way of cross ventilation to form shall be. The conclusion follows. Analyzed the distribution of comfort, room was a little hot and humid. To fall the sensory temperature, ventilation should be introduced. Design parameters due to changes in the analysis of the way of cross ventilation are as follows. Inflow hole is divided into two places away from each other, and the way of cross ventilation are formed more effectively. In addition to the open balcony windows to the left the entire room air distribution is considered to be effective.